To measure ripple/noise, you must first know the correct measurement method. Many engineers use digital oscilloscopes to measure ripple/noise values of several hundred mV, which are dozens of times different from the parameter specifications. This is definitely caused by incorrect measurement methods.
The following points will affect the accuracy of power supply ripple/noise measurement:
1. The noise floor and quantization error of the oscilloscope
2. Using a probe with a large attenuation factor to measure a small voltage
3. The distance between the GND and signal detection points of the probe is too large
4. The setting of the oscilloscope channel (50Ω and 1MΩ, DC coupling or AC coupling)
1 Requirements for instruments
Oscilloscope parameter requirements:
Support bandwidth limitation or digital filtering function: Generally, oscilloscopes support 20MHz bandwidth limitation, and also have more advanced full bandwidth limitation function, such as: SDS2000 series, impedance requirements are 50 ohms and 1M ohms optional.
The power supply and ground impedance at the chip end are usually in the milliohm level. After the high-frequency power supply noise is transmitted from the coaxial cable to the oscilloscope channel, when the oscilloscope input impedance is 50 ohms, the characteristic impedance of the coaxial cable of 50 ohms is completely matched with the channel, and there is no reflection; when the channel input impedance is 1M ohms, it is equivalent to high impedance. According to the transmission line theory, the power supply noise is reflected, thus causing the power supply noise tested at 1M ohm input impedance to be higher than that of 50 ohms.
Probe requirements:
To make the ground wire as short as possible, you can configure a short test pin for the probe, or make your own short ground wire: remove the probe ground wire sleeve, and wind a short ground wire with metal wire. Category 5 copper wire is recommended, which has moderate strength. You can also use solder wire, aluminum wire, etc.
Select the 1X non-attenuation position. Generally, when the passive probe is in the 1X position, its bandwidth is limited to 6MHz/10MHz. In this way, the interference of high-frequency ripple/noise can be effectively filtered out at the front end, reducing the impact of ripple/noise measurement. If the 10X position is selected, not only will there be no filtering effect, but the ripple/noise signal will be severely attenuated, which will increase the difficulty of observation.
Taking Dingyang's SDS2000 as an example, the correct operation steps for routine measurements are as follows:
1. Turn on the bandwidth limit function of SDS2000 and limit the oscilloscope bandwidth to 20MHz. The purpose is to avoid the high-frequency ripple/noise of the digital circuit affecting the measurement and to ensure the accuracy of the measurement as much as possible; at the same time, the impedance is selected as 50Ω.
2. Set the coupling mode to AC coupling to avoid the oscilloscope not being able to display the ripple/noise signal due to the DC signal being too large, which is convenient for measurement (use a smaller gear to carefully observe the ripple/noise, and don't care about the DC level); under DC coupling, when the range is 2mV or even smaller, the bias voltage of some oscilloscopes is not enough. The voltage offset range of Dingyang SDS2000 oscilloscope is as follows,
3. Ensure that the probe grounding is as short as possible. If the distance between the probe and the ground is far, a lot of EMI noise will be radiated into the signal loop of the probe. As shown in Figure 1, the waveform observed by the oscilloscope includes other signal components, resulting in incorrect test results. Therefore, the distance between the probe signal and the ground detection point should be minimized as much as possible to reduce the loop area. (The main reason for measuring ripple/noise of hundreds of mV is that the ground wire is too long.) You can remove the ground wire and shell of the probe to expose the probe ground shell, and wrap the ground wire around the probe ground shell. This can effectively ensure that the length of the ground wire is less than 1cm; (This is the key point. The ripple/noise is originally a small signal. The inductance effect caused by the long ground wire will cause greater ripple/noise interference to the measurement.)
2 Actual test of a ripple/noise signal:
Measure the ripple/noise of a DC power supply, as shown below:
First, use a high impedance to test the ripple/noise, as shown in Figure 3;
Secondly, use 50Ω to test the ripple/noise, as shown in Figure 4;
During the test, we found that if a probe with 1x attenuation is used for testing, when the oscilloscope channel input is 1M ohm, the power supply noise measured is usually greater than that of a 50 ohm input impedance. This is because after the high-frequency power supply noise is transmitted from the coaxial cable to the oscilloscope channel, when the oscilloscope input impedance is 50 ohms, the impedance of the coaxial cable is 50 ohms and the channel is completely matched without reflection; when the input impedance is 1M ohms, that is, high impedance, the power supply noise will be reflected, which will cause the noise of the 1M ohm test to be greater than that of the 50 ohm test.
Therefore, when measuring small power supply noise, it is recommended to use a 50 ohm input impedance.
Previous article:Measuring the power output of solar cells using test equipment
Next article:Design of Digital Storage Oscilloscope Based on DSP
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
- How to measure the quality of soft start thyristor
- How to use a multimeter to judge whether a soft starter is good or bad
- What are the advantages and disadvantages of non-contact temperature sensors?
- Innolux's intelligent steer-by-wire solution makes cars smarter and safer
- 8051 MCU - Parity Check
- How to efficiently balance the sensitivity of tactile sensing interfaces
- What should I do if the servo motor shakes? What causes the servo motor to shake quickly?
- 【Brushless Motor】Analysis of three-phase BLDC motor and sharing of two popular development boards
- Midea Industrial Technology's subsidiaries Clou Electronics and Hekang New Energy jointly appeared at the Munich Battery Energy Storage Exhibition and Solar Energy Exhibition
- Guoxin Sichen | Application of ferroelectric memory PB85RS2MC in power battery management, with a capacity of 2M
- Analysis of common faults of frequency converter
- In a head-on competition with Qualcomm, what kind of cockpit products has Intel come up with?
- Dalian Rongke's all-vanadium liquid flow battery energy storage equipment industrialization project has entered the sprint stage before production
- Allegro MicroSystems Introduces Advanced Magnetic and Inductive Position Sensing Solutions at Electronica 2024
- Car key in the left hand, liveness detection radar in the right hand, UWB is imperative for cars!
- After a decade of rapid development, domestic CIS has entered the market
- Aegis Dagger Battery + Thor EM-i Super Hybrid, Geely New Energy has thrown out two "king bombs"
- A brief discussion on functional safety - fault, error, and failure
- In the smart car 2.0 cycle, these core industry chains are facing major opportunities!
- The United States and Japan are developing new batteries. CATL faces challenges? How should China's new energy battery industry respond?
- Murata launches high-precision 6-axis inertial sensor for automobiles
- Ford patents pre-charge alarm to help save costs and respond to emergencies
- New real-time microcontroller system from Texas Instruments enables smarter processing in automotive and industrial applications
- [Reprint] Summary of Zynq7010 NAND startup
- Free sharing of LDO and DCDC basic principle explanation video
- No response when controlling GPIO in user mode?
- Logistics POS machine with serial port expansion IC
- EEWORLD University Hall----Live Replay: Infineon system solutions make electric motorcycle design more reliable and efficient!
- EEWORLD University Hall----Live Replay: ADI's smoke detector integrated solution based on ADPD188BI
- How to use 4G base stations and 5G base stations in rural areas
- EEWORLD University Hall----Live Replay: Fujitsu Empowers Automotive Electronics Technology Transformation
- Fault Detection of Small Signal Analog Amplifier Circuit
- MSP430G2553 MCU Programming Experience