zip

Using AD594 and AD595 to Condition Thermocouple Signals

  • 2013-06-14
  • 683.29KB
  • Points it Requires : 2

Conditioning Thermocouple Signals Using AD594 and AD595 Thermocouples are one of the most widely used temperature measurement devices. Whether in industrial, commercial or scientific applications, thermocouples can provide cost-effective temperature measurement solutions in many wide temperature range environments. However, the basic working principles of thermocouples are often misunderstood, resulting in serious measurement errors. This application note will review the basics of thermocouples and explain the design of thermocouple signal conditioning circuits using the single-chip IC AD594/AD595.