When the G40 single screw pump is used to pump concentrated sludge, it has constant faults, 80% of which are caused by rotating parts, such as wear and deformation of connecting holes and cylindrical pins. Adding counter-perforations and local quenching can reduce maintenance time, extend service life, and save maintenance costs.