Using DCS to implement signal interlocking protection of EAST cryogenic system

  • 2013-09-22
  • 250.47KB
  • Points it Requires : 2

This paper introduces the implementation of signal alarm and interlock protection between EAST cryogenic system and master control on DeltaV DCS. Firstly, the system requirements and design scheme of interlock protection are introduced, then the control logic of interlock protection is explained in detail, and the corresponding software configuration is provided, including the configuration of manual button monitoring interface and the configuration of interlock module. Keywords: EAST cryogenic system; interlock protection; DeltaV distributed control system; module configuration \"EAST (Experimental Advanced Superconductive Tokamak) is a new generation of all-superconducting tokamak controlled nuclear fusion experimental device and a national 95 major scientific project. The cryogenic system is one of the core subsystems of EAST, responsible for providing cooling for each cooling component of EAST to make the fusion device enter the superconducting state. The stable operation of the cryogenic system plays a vital role in the performance and safety of the EAST device and the success and efficiency of the plasma discharge experiment. Before the EAST discharge experiment, the master control must check the preparation of each subsystem. Only when each subsystem meets the experimental conditions can it be officially powered on for the plasma discharge experiment. At the same time, if a subsystem fails during the experiment, it must also notify the master control, which will determine the degree of the failure and then issue commands to other subsystems to perform corresponding fault operations. As one of the important subsystems of the EAST device, the signal monitoring between the cryogenic system and the master control must be carried out in real time. The signal alarm and interlock protection are very important for the successful plasma discharge experiment of the EAST device. DCS The control applied to cryogenic systems can greatly increase the stability and reliability of the system. Using DeltaV DCS to realize the signal interlocking function between the cryogenic system and the master control can give full play to the advantages of DeltaV controllers, quickly and accurately monitor and alarm the signals, and effectively perform protection operations on the cryogenic system.

unfold

You Might Like

Uploader
froglucky
 

Recommended ContentMore

Popular Components

Just Take a LookMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号
×