TAC series(200,250,300A)
R
Three phase input type(1-stage filter)
Ordering information
TAC -200 -223
1
2
3
4
-O
1
Model Name
2
Rated Current
3
Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code
103
223
333
Line to ground
Leakage Current
capacitor
(Input 250/500V 60Hz)
(nominal value)
1.0mA/2.0mA max
10,000pF
2.5mA/5.0mA max
22,000pF
3.5mA/7.0mA max
33,000pF
*
When the line to ground capacitor code is
different, the attenuation characteristic is
different.
4
Option
U:Improve differential mode attenuation
(Rated voltage 250V)
Features of TAC series
High-attenuation type of common mode noise from 150kHz to 1MHz (1-stage filter)
-
Three phase rated voltage 500 VAC (voltage range:528V max)
-
Selectable leakage current value
Specifications
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Items
Rated Voltage[V]
Rated Current[A]
Test Voltage (Terminal-Mounting Plate)
Isolation Resistance (Terminal-Mounting Plate)
Leakage current 250/500V 60Hz
DC registance
Safety agency approval temperatures
Operating temperature
Operating humidity
Storage temperature/humidity
Vibration
Impact
Safety agency approvals
Case size (without projection)
Weight
TAC-200-223
TAC-250-223
TAC-300-223
AC Three Phase 500 (voltage range:528 max) 50/60Hz
*1
200
250
300
2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity
500 VDC 100MW min at room temperature and humidity
2.5mA/5.0mA max
2mW max
1.5mW max
1mW max
-25 to +85C (Refer to Derating Curve)
-40 to +85C (Refer to Derating Curve)
20 to 95%RH (Non condensing)
-40 to +85C/20 to 95%RH (Non condensing)
10 to 55Hz, 19.6m/s
2
(2G), 3min. Period, 1hour each X, Y and Z axis
196.1m/s
2
(20G), 11ms Once each X, Y and Z axis
UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC
190X110X360 mm [7.48X4.33X14.17 inches] (WXHXD)
8.0kg max
*1
Only “TAC-OOO-OOO-U”, Three Phase 250 (275 max)
Circuit Diagram
(1) TAC-OOO-OOO
LINE
Case
LOAD
Derating Curve
1
2
3
CY CY CY
CY CY CY
4
5
6
100
Load Factor [%]
80
60
40
20
0
-40
-30
-20
40
50
60
70
80
90
CY : Line to ground capacitor
: Mounting Plate
(2) TAC-OOO-OOO-U (Option : U)
LINE
Case
LOAD
Ambient Temperature [C]
*Keep
free ventilation holes for cooling.
1
2
3
CY CY CY
CY CY CY
4
5
6
CY : Line to ground capacitor
: Mounting Plate
NF-74
TAC series (200,250,300A)
External view
[14.17]
360
M8
Protection Earth
110
282.5
3-f6.5
[0.26]
[0.26]
[11.12]
[4.33]
[3.29]
83.5
[1.65]
160
±0.5
[7.48]
Name Plate
190
[6.3]
42
3-M10
Output
Terminal
6.5
3-M10
Input
Terminal
[1.46]
37
M8
Protection Earth
Mounting Plate
340
Mounting Hole
¶
Can not be mounted upside-down.
(mounted the top surface)
¶
Tolerance :
±1
[±0.04]
¶
Weight : 8.0kg max
¶
Mounting Plate : Stainless steel t=2.0 [0.08]
¶
Dimensions in mm, [ ]=inches
¶
Terminal block screw tightening torque M10 : 14.2N-m (144.9kgf-cm) max
¶
Protection Earth screw tightening torque M8 : 9.2N-m (93.9kgf-cm) max
Terminal Cover
±0.5
[13.39]
Mounting Hole
[0.26]
6.5
[0.26]
6.5
NF-75