P Series Data Sheet
90 – 192 Watt DC-DC Converters
Features
• RoHS lead-free-solder and lead-solder-exempted
products available
• Wide input voltage ranges up to 154 VDC
• 1, 2, 3 or 4 isolated outputs up to 96 V
• Class I equipment
• Compliant with EN 45545 and NF-F-16 (version V114
or later)
• Very high efficiency up to 90%
• Extremely low inrush current, hot-swappable
• Excellent surge and transient protection
• Many output configurations available with flexible load
distribution
• Externally adjustable output voltage
• Inhibit primary referenced
• Redundant operation (n+1), sense lines, current
sharing option
• Extremly slim case (4 TE, 20 mm), fully enclosed
111
4.4"
3U
20
0.8"
4 TE
164
6.5"
• Hipot test voltage up to 2.8 kVDC (Version V114 or later)
• All PCBs coated with protective lacquer
• Telecom-compatible input voltage range of DP models
according to ETS 300132-2
• CompactPCI-compatible output voltage (xP4720)
Safety-approved to the latest edition of IEC/EN
60950-1 and UL/CSA 60950-1.
Description
These extremely compact DC-DC converters incorporate all
necessary input and output filters, signaling and protection
features, which are required in the majority of applications.
The converters provide important advantages, such as
flexible output power through primary-side current limitation,
extremely high efficiency, excellent reliability, very low ripple
and RFI noise levels, full input-to-output isolation, negligible
inrush current, soft start, overtemperature protection and
input over- and undervoltage lockout.
The converters are particularly suitable for rugged environ-
ments, such as railway applications. They have been designed
in accordance with the European railway standards EN 50155
and EN 50121-3-2. All printed circuit boards are coated with a
protective lacquer. The converter inputs are protected against
surges and transients occurring on the source lines and cover
a total operating input voltage range from 16 to 150 VDC
with five different model types. The outputs are continuously
open- and short-circuit proof.
Table of Contents
Page
Page
Immunity to Environmental Conditions .............................. 18
Mechanical Data ................................................................. 19
Safety and Installation Instructions .................................... 20
Description of Options ........................................................ 23
Accessories ........................................................................ 24
Model Selection .................................................................... 2
Functional Description .......................................................... 6
Electrical Input Data ............................................................. 7
Electrical Output Data .......................................................... 9
Auxiliary Functions ............................................................. 14
Electromagnetic Compatibility (EMC) ................................ 16
Copyright © 2017, Bel Power Solutions Inc. All rights reserved.
BCD20010-G Rev AN1,
12-Nov-2018
MELCHER
The Power Partners.
Page 1 of 24
P Series Data Sheet
90 – 192 Watt DC-DC Converters
Full system flexibility and n+1 redundant operating mode are
possible due to series or parallel connection capabilities of the
outputs under the specified conditions. When several
converters (with 3.3 and 5.1 V outputs) are connected in
parallel, the T option allows for a single-wire connection
between the converters to ensure good current sharing. LEDs
at the front panel and an isolated Out-OK signal (option)
indicate the status of the converter. Voltage suppressor
diodes and an independent second control loop protect the
outputs against an internally generated overvoltage.
The converters are designed using planar magnetics
transformers and control circuits in hybrid technology. There
are always two powertrains fitted to a converter, each con-
sisting either of a regulated single output with synchronous
rectifier or of a regulated main output with a tracking second
output. The output power may be flexibly distributed among
the main and the tracking output of each powertrain. Close
magnetic coupling in the transformers and output conductors
together with circuit symmetry ensure tight tracking of the
auxiliary output. The switching frequency is fixed.
As a modular power supply or as part of a distributed power
supply system, the low-profile design significantly reduces the
required volume without sacrificing high reliability. The
converters are particularly suitable for 19" rack systems
occupying 3U/4TE only, but they can also be chassis-
mounted by means of four screws. Connector type is H15 (or
H15S2 for some single-output models). The fully enclosed
black-coated aluminum case acts as heat sink and RFI shield
and protects the converter together with the coating of all
components against environmental impacts.
Model Selection
Note:
Only standard models are listed. Other voltage con-
figurations are possible as well; please contact the Company !
Table 1a: Model types BP, CP
Output 1, 4
V
o nom
[V]
3.3
5.1
12
15
24
3.3
5.1
5.1
12
15
24
5.1
5.1
5.1
12
24
5.1, 3.3
7
5.1, 5.1
3
12, 12
3
15, 15
3
24, 24
3
1
2
3
4
5
6
7
8
Output 2, 3
P
o max
[W]
132
183
192
192
192
66
91
91
96
96
96
91
91
91
96
96
50
82
1
96
1
96
1
96
1
V
o nom
[V]
-
-
-
-
-
5.1
5.1
12
12
15
24
12, 12
3
15, 15
3
24, 24
3
15, 15
3
5.1, 5.1
3
12,
15,
12,
15,
24,
12
3
15
3
12
3
15
3
24
3
P
o nom
[W]
-
-
-
-
-
61
61
60
60
60
60
60
1
60
1
60
1
60
1
51
1
60
1
60
1
60
1
60
1
60
1
P
o max
[W]
-
-
-
-
-
91
91
96
96
96
96
96
1
96
1
96
1
96
1
82
1
96
1
96
1
96
1
96
1
96
1
Efficiency
2
, operating input voltage range
η
2
[%]
84
8
87
8
87.5
87.5
88
86
87
87
87.5
87.5
88
87
87.5
87.5
87
-
85
86
87.5
87.5
88
V
i min
–
V
i max4
16–36 V
BP1101-9RG
BP1001-9RG
BP1301-9RG
BP1501-9RG
BP1601-9RG
BP2101-9RG
BP2001-9RG
BP2020-9RG
BP2320-9RG
BP2540-9RG
BP2660-9RG
BP3020-9RG
BP3040-9RG
BP3060-9RG
BP3340-9RG
-
BP4720-9RG
9
BP4040-9RG
BP4320-9RG
BP4540-9RG
BP4660-9RG
η
2
[%]
84
8
88
8
88.5
88.5
89
86
88
88
88.5
88.5
89
89
88.5
88.5
-
87
-
-
88.5
88.5
89
V
i min
–
V
i max4
33.6–75 V
CP1101-9RG
CP1001-9RG
CP1301-9RG
CP1501-9RG
CP1601-9RG
CP2101-9RG
CP2001-9RG
CP2020-9RG
CP2320-9RG
CP2540-9RG
CP2660-9RG
CP3020-9RG
CP3040-9RG
CP3060-9RG
-
CP3601-9RG
CP4720-9RG
9
-
CP4320-9RG
CP4540-9RG
CP4660-9RG
Options
P
o nom
[W]
92
122
120
120
120
46
61
61
60
60
60
61
61
61
60
60
30
51
1
60
1
60
1
60
1
-7
D, T
5
, K
8
B0, B1, B3
non-G
-7
D, T
6
B0, B1, B3
non-G
-7
D
B0, B1, B3
non-G
9
The power of both outputs shall in sum not exceed the total power for the specified ambient temperature.
Min efficiency at
V
i nom
,
P
o nom
,
T
A
= 25 °C. Typical values are approx. 2% better.
Isolated tracking output (±5%
V
o nom
, if each output is loaded with
≥
5% of
P
o nom
). Parallel or series configuration is possible.
Short deviations below
V
i min
and beyond
V
i max
according to EN 50155 possible; see table 2a.
Only available for models with 5.1 or 3.3 V output.
Option T is only available for outputs with 5.1 or 3.3 V. Opt. T excludes opt. R; refer to table 13, pin allocations
Outputs 5.1 and 3.3 V have a common return. Nominal values: 5.1 V / 4 A, 3.3 V / 3 A. Max. values: 5.1 V / 6.5 A, 3.3 V / 5 A.
Option K only for xP1101 and xP1001: H15 standard connector. Models without option K exhibit a better efficiency: xP1101 is approx
2% better, xP1001 approx 1% better than the models with option K.
Compatible with CompactPCI
®
specification
NFND: Not for new designs
Preferred for new designs
BCD20010-G Rev AN1, 12-Nov-2018
MELCHER
The Power Partners.
Page 2 of 24
P Series Data Sheet
90 – 192 Watt DC-DC Converters
Table 1b: Model types DP, EP
Output 1, 4
V
o nom
[V]
3.3
5.1
12
15
24
3.3
5.1
5.1
12
15
24
5.1
5.1
5.1
5.1, 3.3
7
12, 12
3
15, 15
3
24, 24
3
P
o nom
[W]
92
122
120
120
120
46
61
61
60
60
60
61
61
61
30
60
1
60
1
60
1
P
o max
[W]
132
183
192
192
192
66
91
91
96
96
96
91
91
91
50
96
1
96
1
96
1
V
o nom
[V]
-
-
-
-
-
5.1
5.1
12
12
15
24
12, 12
3
15, 15
3
24, 24
3
12,
12,
15,
24,
12
3
12
3
15
3
24
3
Output 2, 3
P
o nom
[W]
-
-
-
-
-
61
61
60
60
60
60
60
1
60
1
60
1
60
1
60
1
60
1
60
1
P
o max
[W]
-
-
-
-
-
91
91
96
96
96
96
96
1
96
1
96
1
96
1
96
1
96
1
96
1
Efficiency
2
, operating input voltage range
η
2
[%]
84
8
88
8
88
88
88
86
88
88
88
88
88
87.5
88
88
85
88
88
88
V
i min
–
V
i max4
η
2
9
[%]
40 –
100.8
V
DP1101-9RG
DP1001-9RG
DP1301-9RG
DP1501-9RG
DP1601-9RG
DP2101-9RG
DP2001-9RG
DP2020-9RG
DP2320-9RG
DP2540-9RG
DP2660-9RG
DP3020-9GR
DP3040-9GR
DP3060-9GR
DP4720-9RG
9
DP4320-9RG
DP4540-9RG
DP4660-9RG
83.5
8
87.5
8
87.5
87
87.5
86
87.5
87.5
87.5
87
87.5
87.5
88
88
-
87.5
87
87.5
V
i min
–
V
i max4
67.2 – 150 V
EP1101-9RG
EP1001-9RG
EP1301-9RG
EP1501-9RG
EP1601-9RG
EP2101-9RG
EP2001-9RG
EP2020-9RG
EP2320-9RG
EP2540-9RG
EP2660-9RG
EP3020-9RG
EP3040-9RG
EP3060-9RG
EP4720-9RG
9
-7
EP4320-9RG
D
EP4540-9RG B0, B1, B3
EP4660-9RG
non-G
-7
D, T
5
, K
8
B0, B1, B3
non-G
-7
D, T
6
B0, B1, B3
non-G
Options
Table 1c: Model types GP
Output 1, 4
V
o nom
[V]
3.3
5.1
12
15
24
3.3
5.1
5.1
12
15
24
5.1
5.1
5.1
5.1, 3.3
7
12, 12
3
15, 15
3
24, 24
3
1
2
3
4
5
6
7
8
Output 2, 3
P
o max
[W]
132
183
192
192
192
66
91
91
96
96
96
91
91
91
50
96
1
96
1
96
1
V
o nom
[V]
-
-
-
-
-
5.1
5.1
12
12
15
24
12, 12
3
15, 15
3
24, 24
3
12,
12,
15,
24,
12
3
12
3
15
3
24
3
P
o nom
[W]
-
-
-
-
-
61
61
60
60
60
60
60
1
60
1
60
1
60
1
60
1
60
1
60
1
P
o max
[W]
-
-
-
-
-
91
91
96
96
96
96
96
1
96
1
96
1
96
1
96
1
96
1
96
1
Efficiency
2
, oper. input voltage range
η
2
[%]
84
8
88
8
88
88.5
88
86
88
87.5
88
88.5
88
87.5
88.5
88.5
-
88
88.5
88
V
i min
–
21.6 – 50.4 V
V
i max4
Options
P
o nom
[W]
92
122
120
120
120
46
61
61
60
60
60
61
61
61
30
60
1
60
1
60
1
GP1101-9RG
GP1001-9RG
GP1301-9RG
GP1501-9RG
GP1601-9RG
GP2101-9RG
GP2001-9RG
GP2020-9RG
GP2320-9RG
GP2540-9RG
GP2660-9RG
GP3020-9RG
GP3040-9RG
GP3060-9RG
GP4720-9RG
9
GP4320-9RG
GP4540-9RG
GP4660-9RG
-7
D, T
5
, K
8
B0, B1, B3
non-G
-7
D, T
6
B0, B1, B3
non-G
-7
D
B0, B1, B3
non-G
9
The power of both outputs may in sum not exceed the total power for the specified ambient temperature.
Min efficiency at
V
i nom
,
P
o nom
,
T
A
= 25 °C. Typical values are approx. 2% better.
Isolated tracking output (±5%
V
o nom
, if each output is loaded with
≥
5% of
P
o nom
). Parallel or series configuration possible
Short deviations below
V
i min
and beyond
V
i max
according to EN 50155 possible; see table 2.
Only available for models with 5.1 or 3.3 V output
Option T is only available for outputs with 5.1 or 3.3 V. Opt. T excludes opt. R; refer to table 13, pin allocations
Outputs 5.1 and 3.3 V have a common return. Nominal values: 5.1 V / 4 A, 3.3 V / 3 A. Max. values: 5.1 V / 6.5 A, 3.3 V / 5 A.
H15 standard connector for xP1101 and xP1001 models; without option K, the
η
value for xP1101 is approx 2% better and for xP1001
approx 1% better than for models with option K.
Compatible with CompactPCI
®
specification; for detailed specification
NFND: Not for new designs
Preferred for new designs
BCD20010-G Rev AN1, 12-Nov-2018
MELCHER
The Power Partners.
Page 3 of 24
P Series Data Sheet
90 – 192 Watt DC-DC Converters
Part Number Description
C P 3 0 20 -9 D T B1 G
Input voltage
V
i nom
:
24 VDC ............................................................... B
48 VDC ................................................................ C
72 VDC ................................................................ D
110 VDC .............................................................. E
36 VDC ............................................................... G
Series ..................................................................................... P
Number of outputs:
Single output (160 mm case)
4 ..........................................
1
Double output (160 mm case)
4 ........................................
2
Triple output (160 mm case)
4 ...........................................
3
Quadruple output (160 mm case)
4 ................................
4
Nominal voltage output 1 /output 4,
V
o1/4 nom
:
3.3 V ..................................................................... 1
5.1 V ..................................................................... 0
12 V ...................................................................... 3
15 V ...................................................................... 5
24 V ...................................................................... 6
other voltages
1 .......................................................................
7, 8
Other specifications and additional features
1
.............. 01, ...99
Nominal voltage output 2 / output 3,
V
o2/3 nom
:
5.1 V ................................................................... 01
3.3 V ................................................................... 10
12 V .................................................................... 20
15 V .................................................................... 40
24 V .................................................................... 60
other voltages and features
1 ............................
80, ... 99
Operational ambient temperature range
T
A
:
–40 to 71 °C ........................................................ -9
–25 to 71 °C (option) ...........................................
-7
others
1
........................................................... 0, -6
Output voltage adjust (auxiliary function) ............................... R
Options:
Out OK output ..................................................... D
Current sharing ................................................. T
2
H15 standard connector ..................................... K
3
Heatsink ............................................... B0, B1, B3
RoHS compliant for all 6 substances ..................................... G
1
2
3
4
Customer-specific models.
Only available for 3.3 V and 5 V outputs. Option T excludes option R, except for single-output models; refer to table 1.
For single-output models with 3.3 V or 5 V output
Models with 220 mm case length. Just add 5000 to the standard model number, e.g. EP8060-9RG.
Note:
The sequence of options must follow the order above. This
description is not intended for creating new part numbers.
Example:
CP3020-9DTB1G: DC-DC converter, input voltage
33.6 to 75 V, 1 regulated output providing 5.1 V, 2
nd
powertrain
with 2
×
12 V, equipped with option D, option T for output 1,
heatsink, ambient temperature –40 to 71 °C, RoHS.
Note:
All models exhibit the following auxiliary functions, which
are not shown in the type designation: input and output filters,
primary referenced inhibit, sense lines (single-, double- and triple-
output models only) and LED indicators.
Product Marking
Basic type designation, safety approval and recognition
marks, CE mark, warnings, pin allocation, patents, company
logo, specific type designation, input voltage range, nominal
output voltages and output currents, degree of protection,
batch no., serial no. and data code including production site,
modification status and date of production. Identification of
LEDs.
BCD20010-G Rev AN1, 12-Nov-2018
MELCHER
The Power Partners.
Page 4 of 24
P Series Data Sheet
90 – 192 Watt DC-DC Converters
Output Configuration
The P Series allows high flexibility in output configuration to
cover almost every individual requirement, by simply wiring
outputs in parallel, in series, or in independent configuration,
as shown in the following diagrams.
Parallel or serial operation of several converters with equal
output voltage is possible, however it is not advantageous to
01006-P
connect converters in parallel without measures to provide
reasonable current sharing. Choose suitable single-output
models, if available.
Note:
Unused tracking outputs should be connected parallel to the
respective regulated output.
01010-P
Triple-output
model
Vo1+
S1+
28
i
30
32
4
12
Single-output
model
R
Vo+
Vo+
S+
16
4
6
12
22
S1–
Vo1–
Vo2+
Vo2–
Load 1
14
8
6
Vi+
Vi–
Load 2
10
18
28
30
32
i
Vi+
Vi–
OK+
OK–
S–
Vo–
Vo–
Load
24
14
8
10
Vo3+
Vo3–
Load 3
20
Fig. 4
Independent triple-output configuration. Output 3 is
tracking
JM200
Fig. 1
Standard configuration (single-output model)
01007-P
Double-output
model
Vo2+
S2+
S2–
Vo2–
28
30
32
Quadruple-
output
Vo1+
model
Vo1–
28
i
30
32
4
8
12
14
6
Load 1
Load 4
6
18
20
10
Vo4+
Vo4–
Vo2+
Vo2–
Vi+
Vi–
Load 2
10
18
i
Vi+
Vi–
Vo1+
S1+
S1–
Vo1–
Load
4
12
14
8
Vo3+
Vo3–
Load 3
20
Fig. 2
Series output configuration of a double-output model.
The second output is fully regulated.
01013b-P
Fig. 5
Common ground configuration of output 1 with 4 and
independent configuration of output 2 and 3
01012Pa
Double-output
model
Vo1+
S1+
28
i
30
32
Quadruple- Vo3+
output
Vo3–
model
Vo2+
28
i
18
20
6
10
4
12
14
8
6
18
20
10
Vo2–
Vo4+
Vo4–
Vo1+
R
S1–
Vo1–
Vo2+
S2+
S2–
Vo2–
Load 1
30
32
Load
12
14
4
R
2
16
R
1
8
Vi+
Vi–
Vi+
Vi–
Load 2
Vo1–
Fig. 3
Independent double-output configuration. Both outputs
are fully regulated
Fig. 6
Series configuration of all outputs (V
o
= 96 V for xP4660).
The R-input influences only outputs 1 and 4. For the
values of R1 and R2, see Output Voltage Adjust.
BCD20010-G Rev AN1, 12-Nov-2018
MELCHER
The Power Partners.
Page 5 of 24