Power Supply Selection Guide
OMRON Power Supply BEST LINE-UP-Suitable
for various situations from Machine to DIN Rail-mounting type
General purpose Power Supply
for various situations from machine to control panel
S8JC-Z
Exceptional cost model
Exceptional cost model.
Wide output Voltage Specifications: 5V to 48V
Input voltage range: 200-240 VAC
S8JC-ZS
Conformed to CE marking
Exceptional cost model with CE Conformed.
Expanded operating temperature:-20 to 70˚C
2-years warranty
S8JX-G
Standard model
Universal Standard Power Supply: Conforming to various safety standards/100-240VAC
Easy Mounting: Front-mounted type, DIN Rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models)
S8JX-P
Use of various application
Limits for harmonic current emissions (conforms to EN61000-3-2)
Conforms to EMI EN55011 Class B
Easy Mounting: Front-mounted type, DIN Rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models)
DIN Rail-mounting type
Optimum for Control panel
S8VS
Models with Indication/Simple Function models
Models with indication [Output Voltage] [Output Current] [Peak hold current]
Models with Maintenance Forecast Monitor or Total Run Time Monitor.
Models without indication (Simple Function models). Compact/Thin body (15 to 480W):
Depth is 130mm or less. Conforms to EMI EN55011 Class B
S8VE
Without indication model
Compact/Thin body (15 to 240W): Depth is 130mm or less Low-cost type of DIN Rail-
mounting
S8VT
Three-phase Input Switch Mode Power Supply
2
Selection Guide of Switch Mode Power Supply
STEP
1
150W
350W
STEP
2
STEP
3
A
B
Power rating / Output voltage
Configuration /Mounting
Models selection
ion l
Function list
xt page
age
next pag
15W
48V
35W
50W
100W
Bottom-mounting
24V
12V
5V
Covered
Power
Supplies
DIN Rail-mounting
P8
P8
15W
24V
35W
50W
100W
150W
350W
Bottom-mounting
12V
Covered
Power
Supplies
DIN Rail-mounting
P9
C
D
P9
5V
15W
48V
24V
15V
12V
5V
35W
50W
100W
150W
300W
600W
Open type
Power Supplies
Covered Power
Supplies
Front-mounting
DIN Rail-mounting
Front-mounting
DIN Rail-mounting
P10
P10
P11
P11
E
F
G
H
50W
48V
24V
12V
5V
100W
150W
300W
600W
Open type
Power Supplies
Covered Power
Supplies
Front-mounting
DIN Rail-mounting
Front-mounting
DIN Rail-mounting
Without mounting brackets
P12
P12
P12
P12
P12
I
J
K
L
M
15W
24V
12V
30W
60W
90W
120W 180W 240W 480W
Models with Indication Monitor
(Maintenance Forecast Monitor)
Models with Indication Monitor
(Total Run Time Monitor)
Models without
Indication Monitor
P13
P13
P13
N
O
P
5V
60W
90W
120W 180W 240W
24V
Models without
Indication Monitor
P14
Q
120W
24V
240W 480W 960W
Models without
Indication Monitor
P14
R
3
Switch Mode Power Supply
BEST LINE - UP
List of functions
General purpose Power Supply
S8JC-Z
[ Exceptional Cost Model ]
S8JC-ZS
[ Exceptional Cost Model With CE Marking ]
Input voltage
(Voltage range)
200 to 240VAC
(185 to 264VAC)
200 to 240VAC
(185 to 264VAC)
Ambient operating
temperature
-10 to 60°C
*Refer to the derating curve in Engineering Data
-20 to 70°C
*Refer to the derating curve in Engineering Data
Warranty
1year
2year
Fan
NO(50 to 150W)
YES(350W)
NO(50 to 150W)
YES(350W)
Power Boost
Peak Current
Peak Current
Hamonic Current
n
Emissions
missions
m
Alarm
Alarm
m
Outpu
ut
Remot
te
Control
o
ol
Hamonic Current
n
Emissions
missions
m
Alarm
Alarm
m
Outpu
ut
Remot
te
Control
o
ol
Additional
function
Remote
e
Sensing
ensing
e
Pa el
arall
Operati
Operation
eration
t
Sereie
e
es
Operati
O
ti
ion
i
Remote
e
Sensing
ensing
e
Pa el
arall
Operati
Operation
eration
t
Sereie
e
es
Operati
O
ti
ion
i
Maiintrance
Forecast Monitor
a
Voltage and
t a
Current Disp y
e splay
s
Maiintrance
Forecast Monitor
a
Voltage and
t a
Current Disp y
e splay
s
EMI
Approved
standards
—
Main application
All FA
Applications
A
Machine Tools and
Processing Equipment
All FA
Applications
A
Machine Tools and
Processing Equipment
Conveyance
Equipment
Conveyance
Equipment
C
Control Panel
Panel
New Energy
Elevator
Control
Control Panell
4
General purpose Power Supply
S8JX-G
[ Economic Models ]
S8JX-P
[ Standard Models ]
Input voltage
(Voltage range)
15W to 100W,150W 12V/24V/48V : 100 to 240 VAC
(85 to 264 VAC,80 to 370 VDC)
*1
150W 5V,300W,600W : 100 to 120 VAC(85 to 132 VAC),
200 to 240 VAC(170 to 264 VAC)
100 to 240 VAC
(85 to 264 VAC, 80 to 370 VDC)
*1
Ambient operating
temperature
-10 to 60°C
*Refer to the derating curve in Engineering Data
-10 to 60°C
*Refer to the derating curve in Engineering Data
Expected life
10year
10year
Fan
NO(15 to 150W,300W(24V/48V))
YES(300W(5V/12V),600W)
NO(50 to 150W)
YES(300W, 600W)
*2
Power Boost
Peak Current
Peak Current
*3
*3
Hamonic Current
n
Emissions
missions
m
Alarm
Alarm
m
Outpu
ut
Remot
te
Control
o
ol
Hamonic Current
nic
Emissions
Alarm
Alarm
m
Output
Outpu
ut
Remot
Remote
Control
*2
*3
*3
Additional
function
Remote
e
Sensing
ensing
e
Pa el
Parallel
arall
Operation
Operati
Operation
eration
t
Sereies
Operati
Operation
O
ti
ion
Remote
Se
Sensing
ensing
Pa el
Parallel
arall
Operati
Operation
Operation
eration
t
Sereies
Operati
Operation
O
ti
ion
*3
Maiintrance
Forecast Monitor
a
Voltage and
t a
Current Disp y
e splay
s
Maiintrance
Forecast Monitor
a
Voltage and
t a
Current Disp y
e splay
s
EMI
Approved
standards
Main application
All FA
Applications
Machine Tools and
Processing Equipment
Conveyance
Equipment
All FA
Applications
Machine Tools and
Processing Equipment
New Energy
Elevator
New Energy
Control
Control Panell
O
Office Equipment
M
Measurement
t
Equipment
Semiconductor
Ma
Manufacturing Equipment
anufacturing Equipment
a
*1. The range for compliance with EC Directives and safety standards(UL,EN,etc.)is 100 to
240 VAC(85 to 264 VAC).
*2. Only 300W / 600W
*3. Except 150W 5V / 300W / 600W
*1. The range for compliance with EC Directives and safety standards(UL,EN,etc.)is 100 to
240 VAC(85 to 264 VAC).
*2. Only 300W 24V / 600W 24V
*3. Only 300W / 600W
5