Distributed power, medical, ATE, communications, defense and aerospace
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V48A12T500BL2
V4 8 A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
264W
5V
400W
8V
400W
12V
500W
15V
500W
24V
500W
28V
500W
36V
500W
48V
500W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Output Voltage
3 V 3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
48V Input Maxi Family
Page 1 of 11
Rev 8.4
06/2016
vicorpower.com
800 927.9474
48V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
29.4
75.7
34.9
30.5
78.8
82.5
2.5
Min
36
Typ
48
Max
75
100
35.7
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.2
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 6.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
48V Input Maxi Family
Page 2 of 11
Rev 8.4
06/2016
vicorpower.com
800 927.9474
48V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
48V Input Maxi Family
Page 3 of 11
Rev 8.4
06/2016
vicorpower.com
800 927.9474
48V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.
3V
OUT
, 264W (e.g. V48A3V3C264BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.5
4.14
Typ
82.8
90
4.3
8
±0.1
94.7
92
Max
113
4.46
11.1
±0.3
80
108
112
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <25 mV
0
81.6
56
5V
OUT
, 400W (e.g. V48A5C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
6.03
Typ
84.5
80
6.25
7.3
±0.02
92
92
Max
100
6.47
11
±0.2
80
104
104
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
8
8V
OUT
, 400W (e.g. V48A8C400BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
84.5
9.36
Typ
85.5
250
9.7
13
±0.02
57.5
57.5
Max
313
10.1
14.5
±0.2
50
67.5
67.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
51
35
12V
OUT
, 500W (e.g. V48A12C500BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.5
13.7
Typ
88.5
200
14.3
10.8
±0.02
48
48
Max
250
14.9
15
±0.2
41.67
54.3
54.3
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
42.5
29.1
15V
OUT
, 500W (e.g. V48A15C500BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
pation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.5
17.1
Typ
88.6
146
17.8
10
±0.02
38.3
38.3
Max
330
18.5
16
±0.2
33.33
45
46.7
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off) Dissi-
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
33.9
3.8
48V Input Maxi Family
Page 4 of 11
Rev 8.4
06/2016
vicorpower.com
800 927.9474
48V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
24V
OUT
, 500W (e.g. V48A24C500BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86
27.1
Typ
87.5
75
28.1
8
±0.02
23.4
23.4
Max
94
29.1
12
±0.2
20.83
25.1
25.1
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
21.3
14.6
28V
OUT
, 500W (e.g. V48A28C500BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.5
31.5
Typ
89.9
50
32.7
11
±0.02
20.6
20.6
Max
63
33.9
12.5
±0.2
17.86
23.3
24.2
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
18.2
12.5
36V
OUT
, 500W (e.g. V48A36C500BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.5
40.4
Typ
86.8
120
41.9
9.9
±0.02
16
16
Max
150
43.4
10.9
±0.2
13.89
18.8
18.8
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
14.1
9.73
48V
OUT
, 500W (e.g. V48A48C500BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.7
53.7
Typ
89.7
218
55.7
7.6
±0.02
12
12
Max
273
57.7
11.4
±0.2
10.42
13.6
14.8
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I would like to ask what does the following candece constraint rule line width mean? I just started learning and I saw that the video tutorials all had a number. I have never seen this before so I wan...
Hi, everyone~~The latest review information is here~~Come and see what information is available this week!Evaluation activities currently being requested:
1. Last day + !!! !!! !!! Free trial of Lingd...
Gallium nitride (GaN) semiconductors have physical properties comparable to those of silicon devices. Conventional power supply metal oxide semiconductor field effect transistors (MOSFETs) and insulat...
I would like to thank EEWORLD and National Technology for giving me the opportunity to evaluate the N32G430 development board.It has been several months since I last used the N32G45XVL development boa...
https://blog.adafruit.com/2019/11/19/circuitpython-5-0-0-beta-0-released-adafruit-circuitpython/5.0.0 is the latest major version of CircuitPython. It features many improvements and enhancements to di...
Xerox announced on Monday that it has raised its offer for HP to $24 per share, for a total value of about $34 billion. According to the new offer, Xerox will acquire HP for $18.4 per share in cash...[Details]
According to research by SellCell, Samsung's Galaxy S22 series smartphones depreciated almost three times more than the iPhone 13 in the first two months after their release. Samsung released the G...[Details]
The switching power supply is a frequently used accessory in the automation system control supporting equipment, and its role is very important. Based on this, the troubleshooting of the switching ...[Details]
On February 3, the Beijing Economic and Technological Development Zone held a signing ceremony for the "Two Districts" construction projects with the theme of "Sharing Opportunities, Seeking Cooperat...[Details]
As a technical engineer, I often receive inquiries and go out to provide technical support. When I arrive at the user's site, I find that many companies' test instruments are too old. Some have even ...[Details]
In 1994, if someone talked to you about EDA, you would definitely be full of questions; but if you talk about EDA today, maybe the old man playing chess on the street would also "chat" to you for a f...[Details]
Quartz crystal oscillator is called "crystal oscillator" for short. It is widely used in electronic clocks, intercoms, single-chip microcomputers, color TV display line field oscillation frequency d...[Details]
RISC-V architecture, which is regarded as one-third of the CPU market, is conquering the market along the AIoT route of "surrounding the city from the countryside". Such a development speed is unprec...[Details]
I recently made a board. stm32rbt6, after downloading the first program, I found that the LED light was flashing, indicating that the program was running normally. But after adding a few pieces of cod...[Details]
The switching characteristics of transistors in digital circuits have two most common applications: one is control application and the other is drive application. The so-called control is as shown in...[Details]
Last night, some IT Home netizens reported that the Xiaomi classmate service on their Xiaomi devices encountered a malfunction and could no longer be used. Xiao Ai has now responded, saying th...[Details]
To celebrate International Women in Engineering Day 2020, element14 (part of Avnet Group), a global distributor of electronic components and development services, held a special exchange meeting to c...[Details]
Dialog’s highly efficient and cost-effective PMICs provide a ‘perfect match’ power solution for Telechips’ latest products London, UK and Seoul, South Korea, September 16, 2020 – Dialog Semiconductor...[Details]
Tesla recently applied for a new patent that can use the on-board laser system to clean the front and rear windshields and cameras, and even remove debris from the roof solar panels. It is reported t...[Details]
We offer a wide range of options based on height, number of cores, heat resistance, and noise resistance.
It can be widely used in consumer, industrial and automotive equipment.
...[Details]