EEWORLDEEWORLDEEWORLD

Part Number

Search

DR2260A30UJ

Description
Trigger Output SSR,
CategoryLED optoelectronic/LED    photoelectric   
File Size1006KB,8 Pages
ManufacturerCrydom
Websitehttp://www.crydom.com/en/index.shtml
Download Datasheet Parametric View All

DR2260A30UJ Overview

Trigger Output SSR,

DR2260A30UJ Parametric

Parameter NameAttribute value
Objectid7333201947
Reach Compliance Codecompliant
Optoelectronic device typesTRIGGER OUTPUT SSR
Datasheet
DR22 Series
AC Output DIN Rail Mount SSRs
Output ratings up to 35 Amps at 600 VAC
Built-in overvoltage protection
Relay or Contactor configuration
Integral heat sink eliminates the need for complex thermal calculations
DBC substrate for superior thermal performance
"Elevator" screw option to allow the use of ring or lug type terminals
IP20 touch-safe housing
AC or DC control
C-UL-US and TUV approved
20A
DR2260A20x
DR2260D20x
DIN Rail Mount
PRODUCT SELECTION
Control Voltage
90-280 VAC/VDC
4-32 VDC
30A
DR2260A30x
DR2260D30x
35A
DR2260A35x
DR2260D35x
AVAILABLE OPTIONS
Series
Operating Voltage
60:
48-600 VAC
Rated Load Current
20:
20 Amps
30:
30 Amps
35:
35 Amps [High I
2
t]
Switching Type
Blank:
Zero Voltage Turn-On
R:
Instantaneous Turn-On
(Motor Rating Certified)
DR22
60
A
20
U
V
R
J
Control Voltage
(1)
A:
90-280 VAC/VDC
D:
4-32 VDC
Required for valid part number
For options only and not required for valid part number
Terminal Layout
Input Connector
U:
Relay Configuration
Blank:
Screw Terminal
V:
Contactor Configuration
J:
Spring Terminal
(std. screw)
(V and W suffixes only)
W:
Contactor Configuration
(elevator screw)
OUTPUT SPECIFICATIONS
(2)
Description
Operating Voltage (47-440Hz) [V
RMS
]
Transient Overvoltage [Vpk]
(3)
Maximum Off-State Leakage Current @ Rated Voltage [mA
RMS
]
Minimum Off-State dV/dt @ Maximum Rated Voltage [V/ sec]
Load Current, General Use UL508/LC A IEC62314 @ 40°C [A
RMS
]
Load Current, Motor Starting UL508 FLA/LC B IEC62314 @ 40°C [A
RMS
]
Minimum Load Current [mA
RMS
]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Power Factor (at Maximum Load)
(4)
Motor Rating UL 508/IEC62314 [HP (kW)]: 120 VAC
Motor Rating UL 508/IEC62314 [HP (kW)]: 240 VAC
Motor Rating UL 508/IEC62314 [HP (kW)]: 480 VAC
20A
48-600
1200
1
500
20
8.5/4.8
100
286/300
1.35
409/375
0.5
0.5 (0.37)
1.5 (1.1)
3 (2.24)
30A
48-600
1200
1
500
30
14/7.6
100
716/750
1.35
2563/2343
0.5
1 (0.74)
3 (2.2)
5 (3.7)
35A
48-600
1200
1
500
35
26/14
150
1290/1350
1.3
8320/7593
0.5
2 (1.5)
5 (3.73)
10 (7.4)
INPUT SPECIFICATIONS
(2)
Description
Control Voltage Range
Maximum Reverse Voltage
Minimum Turn-On Voltage
Must Turn-Off Voltage
Minimum Input Current (for on-state)
Maximum Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
DR2260Dxxx
4-32 VDC
(5)
-32 VDC
4 VDC
1 VDC
7 mA
15 mA
Current Limited
1/2 Cycle
(7)
1/2 Cycle
DR2260Axxx
90-280 VAC/VDC
(6)
-
90 VAC/VDC
5 VAC/VDC
6 mA
10 mA
Current Limited
20
30
Do not forget to visit us at:
www.crydom.com
Copyright © 2019 Crydom Inc. Specifications subject to change without notice.

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号