EEWORLDEEWORLDEEWORLD

Part Number

Search

L21-B2-20-410-411-KA

Description
Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size2MB,8 Pages
ManufacturerCarling Technologies
Environmental Compliance
Download Datasheet Parametric View All

L21-B2-20-410-411-KA Overview

Magnetic Circuit Breaker,

L21-B2-20-410-411-KA Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7347469973
Reach Compliance Codecompliant
Country Of OriginMexico
YTEOL7.8
Actuator typeROCKER
Other featuresSTANDARDS: MIL-PRF-55629, MIL-STD-202
body width19.05 mm
body height49.4 mm
Body length or diameter92.58 mm
circuit functionSERIES TRIP
Circuit protection typeMAGNETIC CIRCUIT BREAKER
Environmental characteristicsMOISTURE RESISTANT
Installation featuresPANEL MOUNT
Number of poles1
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Rated breaking capacity5000 A
Rated current1 A
Rated voltage (AC)120 V
surface mountNO
Terminal shapeSCREW
L-Series
Circuit Breaker
Available with Current Transformer
The L-Series high performance, compact hydraulic-
magnetic circuit breaker is ideally suited for the rigors and
confined spaces found in today’s telecom/datacom power
distribution units and rack systems. It provides best in class
performance in an innovative low profile, space saving
package complementing the overall spatial objectives
required by telecommunications and data-communications
systems designers in their quest to reduce the overall size
of equipment, while increasing transmission capacity.
The optional current transformer allows outlet metering
and monitoring of power usage thus facilitating load
adjustments and maximizing efficiency.
Further, a patent
pending flush rocker actuator design and optional push-to-
reset guard offers additional protection against accidental
switching.
Number of poles: 1-3. Maximum current and voltage
ratings: .2-32A, 120/240-240VAC. Maximum interrupting
capacity: 5000 Amps
Applications:
Š
Telecom/Datacom Industry
– Power Distribution Units
– Data Servers
– Data Storage
Product Highlights:
Š
Optional current transformer
Š
Ultra low profile design saves valuable space
Š
Optional handle guard actuator
Š
UL 489 LISTED Branch Circuit breaker
Š
Designed for worldwide datacenter
compatibility with up to 240VAC ratings
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
[AT-START-F425 Review] No.1 Unboxing AT32F425
[i=s] This post was last edited by Yunhu Congbai on 2022-3-28 19:16 [/i] ## Preface This time, the Yatli board was much faster than the Pingtou Ge. The little brother notified me that it was delivered...
韵湖葱白 Domestic Chip Exchange
Showing off your products (6) - silicon lab
[i=s]This post was last edited by dcexpert on 2019-11-9 20:15[/i]Piano (capacitive touch button) development board based on C8051F70XSlider development board based on C8051F990SiM3L1xx LCD Low Power D...
dcexpert Special Edition for Assessment Centres
EEWORLD University - How to draw a high-end PCB ruler with Altium20
How to draw a high-end PCB ruler using Altium20 : https://training.eeworld.com.cn/course/5965How to draw a high-end PCB ruler using Altium20PCB ruler is a practical tool that many engineers need to us...
F凡亿教育 Embedded System
DC-DC converters are used to improve the safety and reliability of power supply.
The design of the special power supply for DC motor servo drive uses DC-DC converter as the basis to realize the power conversion from 220V mains to +60V/20A. The power factor correction technology is...
fish001 Analogue and Mixed Signal
Agitek case sharing - Metrology and testing demonstration case of automotive electronic modules
At the beginning of December 2018 , a customer consulted Agitek Technology. The customer needed to select an oscilloscope and arbitrary waveform generator for the measurement and testing of automotive...
安泰测试设备 Test/Measurement
[N32L43x Review] Problems with transplanting the ink screen
There was a situation where the program got stuck on BKPT, and then I searched and found that the simulation could run but it would freeze without debugging. This is someone else's answer. This kind o...
流行科技 Domestic Chip Exchange

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号