S205TY1

Description
relay ssr 240vac 5A triac 4-sip
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size72KB,5 Pages
ManufacturerSHARP
Websitehttp://sharp-world.com/products/device/
Download Datasheet Compare View All

S205TY1 Overview

relay ssr 240vac 5A triac 4-sip

S105T01/S105T02/S205T01/S205T02
S105T01/S105T02
S205T01/S205T02
s
Features
1. Low profile type (height : 16mm)
2. Built-in zero-cross circuit
(S105T02/S205T02)
3. RMS ON-state current I
T
: MAX. 5Arms
4. Approved by TÜV, No. R9750790
(S205TY1/S205TY2)
Input-Output : Basic Insulation
Low Profile Type
Solid State Relays
s
Outline Dimensions
1.8
±0.2
7
±0.2
(Unit : mm)
Model No.
S105T01
S105T02
S205T01
S205T02
4
±0.2
23
±0.2
5A 125VAC
5A 265VAC
Common to pin No.2
4.5
±0.3
R3.8
±0.2
φ3.7
±0.2
3
±0.2
Common to pin No.2
MIN.
s
Applications
1. Programmable controllers
2. Air conditioners
3. Copiers
4. Automatic vending machines
6.4
±0.2
30
°
±
5
0.5
±0.2
0.1
11.5
±0.2
Epoxy resin
10
±0.2
0.4
±0.1
(1.8)
Z.C.
(25.8)
S105T01
3.8
MAX.
6.2
MIN.
5A125VAC
5
Lot No.
(DIN Standard)
3-1.2
±0.2
3-1.4
±0.3
4-0.8
±0.2
4
(2.54)
+ −
0.2
MAX.
No zero-cross circuit
Built-in zero-cross circuit
For 100V lines
S105T01
S105T02
For 200V lines
S205T01
S205T02
(Ta=25°C)
Unit
mA
V
A
rms
A
1.8
±0.3
1
(5.08)
2
(3.8)
(10.16)
s
Absolute Maximum Ratings
Parameter
Forward current
Reverse voltage
RMS ON-state current
*2
Peak one cycle surge current
S105T01
Repetitive peak
S105T02
OFF-state voltage
S205T01
S205T02
S105T01
Non-repetitive peak
S105T02
OFF-state voltage
S205T01
S205T02
Critical rate of rise of ON-state current
Operating frequency
Operating temperature
Storage temperature
*3
Isolation voltage
*4
Soldering temperature
Input
Symbol
I
F
V
R
I
T
I
surge
Rating
50
6
*1
5
50
400
V
DRM
600
Internal connection diagram
S105T01/S205T01
S105T02/S205T02
V
1
2
1
2
3 4
1
2
3
4
(0.8)
3
s
Model line-ups
1.6
±0.2
(3.5)
1
2
3 4
Z.C. : Zero-cross circuit
Output (Triac T1)
Output (Triac T2)
Input (+)
Input (−)
Output (Triac T1)
Output (Triac T2)
Input (+)
Input (−)
Output
400
V
DSM
600
dI
T
/dt
f
T
opr
T
stg
V
iso
T
sol
50
45 to 65
−25
to
+100
−30
to
+125
3.0
260
A/µs
Hz
°C
°C
kV
rms
°C
V
3
4
5
: Do not allow external connection.
g
( ) : Typical dimensions
*1 Refer to Fig.2, Fig.3
*2 60Hz sine wave, start at Tj=25°C
*3 Isolation voltage measuring method
(1) Dielectric withstand voltage tester with zero cross circuit shall be used.
(2) The applied voltage waveform shall be sine wave.
(3) Voltage shall be applied between input and output.
(Input and output terminals shall be shorted respectively.)
(4) AC 60Hz, 1min, 40 to 60%RH.
*4 For 10s
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/
Notice

S205TY1 Related Products

S205TY1 S205T01 S205TY2 S105T02
Description relay ssr 240vac 5A triac 4-sip relay ssr 240vac 5A triac 4-sip relay ssr 240vac 5A ZC 4-sip Trigger Output SSR, 1-Channel, 3000V Isolation, DIP-4

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号