CMB-Series
Rating:
THERMAL CIRCUIT PROTECTORS
3 to 20A, 125-250VAC, 32VDC
Approvals:
UL, CUL, CSA, TUV, CE
UL1500/ISO8846 for ignition
protection/marine
Dielectric Strength:
2500 VAC/1 minute
Interrupting capacity:
2500 amps
@
32 VDC
Insulation Resistance:
100M ohms
Operating Temperature:
-10°C to 60°C
Voltage drop:
< 0.25 V
Applications:
Household Appliances
Transportation
Marine
Power Strips
Medical Equipment
Audio Visual Equipment
Power Supplies
ROHS Compliant
Dimensional Specifications:
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
2 | CMB-Series Pushbutton Thermal Circuit Protector
1
Series
CMB — 10 3 — 11 C 3 N — B — A /10
2
Rating
3
Voltage
4
Mounting
Hole
5
Bushing
Type
6
Mounting
Nut
7
Indicator
Plate
8
Button
9
Terminal
10
Button Marking
1 SERIES
CMB
2 RATING
03
3 amp
04
4 amp
05
5 amp
06
6 amp
07
7 amp
08
8 amp
5 BUSHING
PLASTIC
C
4
Type C
D
4
Type D
E
5
Type E
G
8
Type G
H
6
Type H
K
13
Type K
METAL
J
8
Type J
6 MOUNTING NUT
7
N
1
2
3
11
4
5
6
14
7
9
8
9
None
Type 1
Type 2
Type 3
Type 4
Type 5
Type 6
Type 7
Type 8
3 VOLTAGE
3
125-250VAC/ 32 VDC
10
12
13
14
15
16
20
10 amp
12 amp
13 amp
14 amp
15 amp
16 amp
20 amp
4 MOUNTING HOLE
11
1
M11
12
2
M12
00
3
Snap In Style
27
9
3/8” 27 UNS
28
12
3/8” 27 UNS
(double flatted)
NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings G, J & K only); Type 3 nut includes molded in “PRESS TO RESET” marking.
Embossed
(ALUMINUM)
.887
[22.5]
.016
[.4]
7 INDICATOR PLATE
7
N
A
B
None
Embossed Legend
Silver Printing
on Black
Silver Printing
On Black
.887
[22.5]
.016
[.4]
All indicator plates are marked
“Suppl. Prot. press to reset”.
8 BUTTON
B
Black
Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified.
1
Used with bushing C or D only.
9
Available with G, J or K bushing only.
2
Used with H bushing only.
10 Amp rating must match button marking
3
Used with bushing E only.
(ex: 20 will be marked on the button of
4
Used with M11 mounting hole only.
CMB-203-27G3N-W-A/20)
5
Used with mounting hole 00 only.
11 Includes molded in “PRESS TO RESET”
6
Used with M12 mounting hole only.
marking.
7
All hardware available separately.
12 Available with K bushing only.
Consult factory.
13 Available with mounting hole 28 only.
8
Available with mounting hole 27 only. 14 Thickness is 3.0 mm, .118 in.
R
Red
W
White
4.5mm
(4.11-4.77mm)
9 TERMINAL
A
B
C
D
E
Type A
Type B
Type C
Type D
Type E
F
G
H
J
Type F
Type G
Type H
Type J
.250 Tab
4.5mm
(4.11-4.77mm)
4.5mm
(4.11-4.77mm)
4.5mm
(4.11-4.77mm)
4.5mm
(4.11-4.77mm)
90˚ Bend Backward
.250 Tab
Screw Terminal
[.41] 10.41
.250 Tab
Mixed Terminals
90˚ Bend Load
4.5mm
(4.11-4.77mm)
Screw Terminal
90˚ Bend
F,G,H,J TERMINALS ARE 8-32 UNC
Type A:
Straight
Type B:
Line Pin
Type C:
Load Pin
Type D:
90˚ Bend
Type E:
Type F:
Type G:
Screw Terminal
90˚ Bend
Type H:
Type J:
10 BUTTON MARKING
(IF BLANK, NO MARKING.)
10
Button Marking Orientation:
03
04
3 amp
4 amp
05
06
5 amp
6 amp
07
08
7 amp
8 amp
10
12
10 amp
12 amp
line
20
load
13
14
13 amp
14 amp
15
16
15 amp
16 amp
20
20 amp
Time Delay
CORRECTION FACTOR
0C
10 C
15 C
18 C
25 C
32 C
40 C
50 C
60 C
o
o
o
o
o
o
o
o
o
x .67
x .72
x .83
x .87
x 1.00
x 1.05
x 1.18
x 1.33
x 1.67
OVERLOAD TRIP TIME
100%
NO TRIP
150%
TRIP IN 1 HR.
200%
5 - 35 SEC.
300%
400%
600%
1 - 10 SEC.
.45 - 5.5 SEC.
.1 - 20 SEC.
Notes:
1 Breaker must hold 100% of rated current
and must trip at 150% and above, within
the time limits shown in curve.
Trip times specified at 25° ambient with
no preloading.
2 To adjust the breaker rating for ambient
temperature multiply the breaker rating
by the factor. (ex: 5 amp rating at 0°C: 5
x .67 = 3.3 amp. Select 3 amp rating.)
2500 amps @ 32 VDC only. AIC rating is
1000 amps for AC applications.
*Manufacturer reserves the right to change product specification without prior notice.