Note: Inclusive of initial frequency accuracy, operating temperature range, supply variation, load variation, 3 times solder reflow, shock, vibration and 1 year aging at 25°C. We do not
recommend hand soldering the devices
REVISION B 12/10/14
3
IDT XO LVDS CRYSTAL OSCILLATOR
XLL DATASHEET
DC Characteristics
(V
DD
= 2.5 V
± 5%, T
A
= - 20°C to +70°C; -40° to +85°C)
Parameter
Power Supply Current
Differential Output Voltage
Output Offset Voltage
Enable/Disable Input HIGH Voltage
(Output enabled)*
Enable/Disable Input LOW Voltage
(Output disabled)
Symbol
I
DD
V
OD
V
OS
V
IH
V
IL
Condition
Common Frequencies
Standard LVDS load
Standard LVDS load
Min
26
Typ
0.4
1.25
Max
65
Units
mA
V
V
V
70%V
DD
30%V
DD
V
* A pullup resistor from pin 6 (VDD) to pin 1 (E/D) enables output when pin 1 is left open.
Note: Inclusive of initial frequency accuracy, operating temperature range, supply variation, load variation, 3 times solder reflow, shock, vibration and 1 year aging at 25°C. We do not
recommend hand soldering the devices
IDT XO LVDS CRYSTAL OSCILLATOR
4
REVISION B 12/10/14
XLL DATASHEET
Output Waveform
Output Levels/Rise Time/Fall Time Measurements
T
R
OUTPUT 2
T
F
20% to 80% V
PP
50% V
PP
V
OS
V
OD
OUTPUT 1
Oscillator Symmetry
Ideally, Symmetry should be 50/50 for ½ period –Other expressions are 45/55 or 55/45
1. Linux development engineerMore than three years of development and debugging experience, familiar with Intel and ARM platforms, and able to develop board-level BSP developers is preferred
2. FPGA d...
An antenna is a device that radiates radio frequency signals from a transmission line into the air or receives them from the air onto a transmission line. It can also be considered as an impedance con...
Awesome MicroPython is a curated list of awesome MicroPython libraries, frameworks, software and resources.[hide]https://awesome-micropython.com/[/hide]...
The digital transformation of manufacturing, known as Industry 4.0, brings together multiple categories of technologies, but competitive advantage comes from whether they work together.On the factory ...
After adding timer 6 (5ms interrupt) to the original project, the system crashed directly. If it was disabled, it would not crash. The platform is cs+ for cacx 4.02.00
Crash at _@vect22 interrupt vect...