PC713VxNSZX Series/PC713VxYSZX Series
PC713VxNSZX Series/
PC713VxYSZX Series
s
Features
1. TTL compatible output
2. Isolation voltage (Viso (rms):5kV)
3. Recognized by UL, file No.E64380
Approved by TÜV (VDE0884)(PC713VxYSZX
Series)
4. 6-pin DIP package
High Isolation Voltage Type
Photocoupler
s
Outline Dimensions
(Unit : mm)
Internal connection
diagram
6
5
4
6
5
4
s
Applications
1. Home appliances
2. Programmable controllers
3. Peripheral equipment of personal computers
6.5
±0.3
Anode
mark
PC713V
Rank mark
1
2
3
0.6
±0.2
1.2
±0.3
1
2
3
7.12
±0.3
7.62
±0.3
s
Model Line-up
*
Model No.
PC713VxNSZX Series
PC713VxYSZX Series
* Application Model No. PC713V
Safty Standard Approval
UL
TÜV(VDE0884)
−
3.25
±0.5
3.5
±0.5
2.9
±0.5
0.5
TYP.
0.26
±0.1
θ
4
5
6
0.5
±0.1
2.54
±0.25
1
θ=0
to 13˚
θ
Anode
Cathode
NC
Emitter
Collector
Base
s
Absolute Maximum Ratings
2
(Ta=25°C)
Unit
mA
A
V
mW
V
V
V
V
mA
mW
mW
kV
°C
°C
°C
3
Parameter
Symbol
Rating
50
Forward current
I
F
*1
Peak forward current
I
FM
1
Input
Reverse voltage
V
R
6
Power dissipation
P
70
Collector-emitter voltage V
CEO
35
Emitter-collector voltage V
ECO
6
Collector-base voltage V
CBO
35
Output
Emitter-base voltage V
EBO
6
I
C
50
Collector current
P
C
150
Collector power dissipation
170
Total power dissipation
P
tot
*2
Isolation voltage V
iso (rms)
5
Operating temperature
−25
to
+100
T
opr
−40
to
+125
T
stg
Storage temperature
*3
260
Soldering temperature T
sol
*1 Pulse width≤100µs, Duty ratio=0.001
*2 40 to 60%RH, AC for 1 min
*3 For 10 s
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/
PC713VxNSZX Series/PC713VxYSZX Series
Fig.3
Peak Forward Current vs. Duty Ratio
10 000
5 000
Peak forward current I
FM
(mA)
2 000
1 000
500
200
100
50
20
10
5
5 10
−3
2
5 10
−2
2
5 10
−1
2
5
1
Forward current I
F
(mA)
Pulse width≤100µs
Ta=25˚C
Fig.4
Forward Current vs. Forward Voltage
500
200
100
50
20
10
5
2
1
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
T
a
=75˚C
50˚C
25˚C
0˚C
−25˚C
Duty ratio
Forward voltage V
F
(V)
Fig.5
Current Transfer Ratio vs. Forward
Current
200
180
Current transfer ratio CTR (%)
160
140
120
100
80
60
40
20
0
1
2
5
10
20
50
Forward current I
F
(mA)
500kΩ
100kΩ
R
BE
=∞
V
CE
=5V
T
a
=25˚C
Fig.6 Collector Current vs. Collector-emitter
Voltage
30
I
F
=30mA
25
Collector current I
C
(mA)
P
C
(MAX.)
20
20mA
R
BE
=∞
T
a
=25˚C
15
10mA
5mA
10
5
0
0
1
2
3
4
5
6
7
8
9
Collector-emitter voltage V
CE
(V)
Fig.7
Relative Current Transfer Ratio vs.
Ambient Temperature
150
I
F
=5mA
V
CE
=5V
R
BE
=∞
100
Fig.8 Collector - emitter Saturation Voltage
vs. Ambient Temperature
Collector-emitter saturation voltage V
CE
(sat) (V)
0.14
I
F
=20mA
0.12
I
C
=1mA
R
BE
=∞
0.10
Relative current transfer ratio (%)
0.08
50
0.06
0.04
0.02
−30
0
−25
0
25
50
75
100
0
20
40
60
80
100
Ambient temperature T
a
(˚C)
Ambient temperature T
a
(˚C)
Application Circuits
NOTICE
qThe
circuit application examples in this publication are provided to explain representative applications of
SHARP devices and are not intended to guarantee any circuit design or license any intellectual property
rights. SHARP takes no responsibility for any problems related to any intellectual property right of a
third party resulting from the use of SHARP's devices.
qContact
SHARP in order to obtain the latest device specification sheets before using any SHARP device.
SHARP reserves the right to make changes in the specifications, characteristics, data, materials,
structure, and other contents described herein at any time without notice in order to improve design or
reliability. Manufacturing locations are also subject to change without notice.
qObserve
the following points when using any devices in this publication. SHARP takes no responsibility
for damage caused by improper use of the devices which does not meet the conditions and absolute
maximum ratings to be used specified in the relevant specification sheet nor meet the following
conditions:
(i) The devices in this publication are designed for use in general electronic equipment designs such as:
--- Personal computers
--- Office automation equipment
--- Telecommunication equipment [terminal]
--- Test and measurement equipment
--- Industrial control
--- Audio visual equipment
--- Consumer electronics
(ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and
safety when SHARP devices are used for or in connection with equipment that requires higher
reliability such as:
--- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
--- Traffic signals
--- Gas leakage sensor breakers
--- Alarm equipment
--- Various safety devices, etc.
(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely
high level of reliability and safety such as:
--- Space applications
--- Telecommunication equipment [trunk lines]
--- Nuclear power control equipment
--- Medical and other life support equipment (e.g., scuba).
qContact
a SHARP representative in advance when intending to use SHARP devices for any "specific"
applications other than those recommended by SHARP or when it is unclear which category mentioned
above controls the intended use.
qIf
the SHARP devices listed in this publication fall within the scope of strategic products described in the
Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export
such SHARP devices.
qThis
publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under
the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any
means, electronic or mechanical, for any purpose, in whole or in part, without the express written
permission of SHARP. Express written permission is also required before any use of this publication
may be made by a third party.
qContact
and consult with a SHARP representative if there are any questions about the contents of this
publication.
115