The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
NEW
SC-Type Optical Fixed Attenuators
HSC-AT11CS Series
s
Features
1. Low return loss, 60 dB min.*
2. Complies with Telcordia GR-910-CORE.
3. High input power (250 mW max.)
4. Variety of fixed attenuation levels.
s
Ordering Information
HSC - AT - 11 - CS - A -
**
1
2
3
4
5
6
CS: APC (>=60dB)
1
Series name: HSC
2
Attenuator
4
Polishing code
s
Applications
1 to 16 dB (in 1 dB increments), 20, 25, and 30 dB
Optical communication and data transfer
equipment requiring in-line fixed power level
adjustment.
5
Optical fiber type A: Single Mode
SC connectors
A:
10, 11, 12, 13, 14, 15, 16, 20, 25, 30
3
Specification series
6
In-line mating with a standard
A:
01, 02, 03, 04, 05, 06, 07, 08, 09,
Part Number
HSC-AT11CS-A01
HSC-AT11CS-A02
HSC-AT11CS-A03
HSC-AT11CS-A04
HSC-AT11CS-A05
HSC-AT11CS-A06
HSC-AT11CS-A07
HSC-AT11CS-A08
HSC-AT11CS-A09
HSC-AT11CS-A10
HSC-AT11CS-A11
HSC-AT11CS-A12
HSC-AT11CS-A13
HSC-AT11CS-A14
HSC-AT11CS-A15
HSC-AT11CS-A16
HSC-AT11CS-A20
HSC-AT11CS-A25
HSC-AT11CS-A30
CL No.
820-9001-2
820-9002-5
820-9003-8
820-9004-0
820-9005-3
820-9006-6
820-9007-9
820-9008-1
820-9009-4
820-9010-3
820-9011-6
820-9012-9
820-9013-1
820-9014-4
820-9015-7
820-9016-0
820-9017-2
820-9018-5
820-9019-8
Attenuation
1dB
2dB
3dB
4dB
5dB
6dB
7dB
8dB
9dB
10dB
11dB
12dB
13dB
14dB
15dB
16dB
20dB
25dB
30dB
Attenuation Tolerance Return Loss
+0.8dB
±0.8dB
±0.8dB
±0.8dB
±0.8dB
±0.8dB
±0.8dB
±0.8dB
±0.9dB
±1.0dB
≥60dB
±1.1dB
±1.2dB
±1.3dB
±1.4dB
±1.5dB
±1.5dB
±1.5dB
±1.5dB
±2.5dB
Wavelength
Split Sleeve
Fiber Type
1310nm
1550nm
Zirconia
SM
2004.7
1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
sSpecifications
Rating
Operating temperature range
Storage temperature range
-40ç to +75ç
-40ç to +75ç
Max. input power
Fiber type
250 mW
SMF
Characteristic
Attenuation
Return loss
Rated input power
Optical characteristic
Environmental characteristic
Mechanical characteristics
Test Method (Conforms with Telcordia GR-910-CORE)
Measurement at a point within the wavelength of 1310 ±30
nm and a point within the wavelength of 1550 ±30 nm.
Power
: 250mW(LD)
Wavelength
: 1470nm
Duration
: 100 hours
Temperature
: -5ç to 50ç
Duration
: 182.5 hours
Humidity
: 15% to 90%
Temperature
: -40ç to 75ç
Period of 1 cycle : 8 hours
Number of cycles : 21
Low-Temperature Exposure and Thermal Shock
Temperature
: 23ç
➝
40ç
➝
-40ç
➝
23ç
Duration
:
2.1h
72 h 5 min. minimum
High-Temperture Exposure and Thermal Shock
Temperature
: 23ç
➝
70ç
➝
70ç
➝
23ç
Duration
:
1.6h
72 h 5 min. minimum
High Relative Humidity Exposure
Temperature
: 23ç
➝
40ç
➝
40ç
➝
23ç
Duration
:
0.6h
96 h 0.6h
Humidity
: 90% to 95%
Temperature
: -10ç to 65ç
Period of 1 cycle : 12 hours
Humidity
: 90% to 100%
Number of cycles : 14
Temperature
: 43ç
Duration
: 168 hours
Solution
: PH 5.5
Vibration frequency range : 10 to 55 Hz
Maximum amplitude: 1.52 mm
Duration
: 2 hours in each of 3 directions
Bend angle
Load
Load
: 90°
: 1.25 kg
: 2 kg
Specification
Refer to the various types of attenuation tolerance (the previous page).
60 dB min.
After / during test, changing in attenuation(fluctuation)shall be less than
±0.1dB.
Controlled Operating
Environment
Uncontrolled Operating
Environment
Non-Operating
Environment
1) After test, change in attenuation(fluctuation)and return loss shall be
1)
as follows.
1)
• Attenuation(fluctuation) : within 0.5 dB
1)
• Return loss
: 60 dB min.
2) No breakage, crack or dislocation of components.
Humidity/Condensation
Cycling Test
Water Immersion
Vibration
Side Pull Load
1) After /during test, change in attenuation(fluctuation)and return loss
1)
shall be as follows.
1)
• Attenuation(fluctuation) : within 0.5 dB
1)
• Return loss
: 60 dB min.
2) No breakage, crack or dislocation of components.
1) After test, change in attenuation(fluctuation)and return loss shall be
1)
as follows.
1)
• Attenuation(fluctuation) : within 0.5 dB
1)
• Return loss
: 60 dB min.
2) No breakage, crack or dislocation of components.
Cable Retention
Durability
Impact Test
Insertion/withdrawal cycles : 200
Drop onto a concrete floor from a height of 1.8 m.
Cycles: 8 times in each of 3 directions
Serial No.
* *
dB
sMaterials
and Dimensions
72516
Component
Body
Ferrule
Split sleeve
Material
Zinc alloy
9.4
Zirconia
35.5
5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8587,JAPAN
PHONE: 81-3-3491-9741, FAX: 81-3-3493-2933
http://www.hirose.com
http://www.hirose-connectors.com
2
12.6
Zirconia