Moisture Sensitivity Level (MSL) – This product is not Moisture Sensitive - MSL = 1
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the
operating temperature ( ref. to
+25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging@25°C±3°C
Insulation Resistance
Drive level dependency (DLD),
minimum 7 points tested: from
1µW to 500µW.
0
-55
-50
-100
See table 1 below
Minimum
1.8432
Typical
Maximum
Units
MHz
1.8432MHz – 24.000MHz
24.01MHz – 66.00MHz
66.01MHz – 122.00MHz
122.01MHz – 160.00MHz
See options
See options
See options
Notes
160.000
Fundamental
3
rd
Overtone
5
th
Overtone
7
th
Overtone
+70
+125
+50
+100
ºC
ºC
ppm
ppm
Ω
7
pF
18
pF
100
1000
µW
±5
ppm
500
MΩ
Change in frequency (Maximum - Minimum) over
DLD range < ±10ppm;
Change in ESR (Maximum - Minimum) over DLD
range < 25% of Max ESR value;
Maximum ESR over DLD range < Max ESR value.
See options
First year
@100Vdc±15V
FREQUENCY (MHz)
1.8432-1.999
2.000-2.399
2.400-2.999
3.000-3.699
3.700-4.199
4.200-4.899
4.900-5.999
6.000-7.999
8.000-9.999
10.000-12.499
12.50-50.00
24.00-66.00
66.01-122.00
122.01-160.00
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Table 1
Operation Mode
HC49/U
Fundamental
HC49/U (3rd OT)
HC49/U (5th OT)
HC49/U (7th OT)
ESR
(Ω)
max
750
550
350
200
100
70
50
40
35
30
25
40
80
120
Revised: 07.09.14
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U CRYSTAL
AB
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
AB -
Frequency in MHz
Please specify the frequency
in xx.xxxxMHz.
e.g. 14.3181MHz
Load Capacitance (pF)
Please specify CL
(Minimum 10pF) in pF or
S for series
Custom ESR if other
than standard
R□
□: Specify
a value in
Ω
(e.g.: R40)
MHz -
-
-
-
-
-
-
Packaging
T: Tape & Reel
Quality Factor***
Minimum
QXXXk
Value
Value Added
I
Insulator Tab
V
Vinyl Sleeve
Trimmed leads
QXX
See Table 2
MJ
Metal jacket
Operation Mode
Fund. AT > 24MHz
F
Fund. BT>24MHz
FB
3
rd
OT>66MHz
O
Freq. Stability
Options for AT-
Cut only*
U**: ± 10 ppm
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 50 ppm
Operating Temp.
A: -10°C ~ +60°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
Freq. Tolerance
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
NOTE:
*:Frequency
Stability ±100
ppm maxat -10 to +60C only
for BT cut.
**:
-10 to +60C only.
***:
Quality factor must be
accompanied by a k value
Table 2
CODES
Q45
Q40
Q35
Q30
Q25
Q20
Q15
Q10
Q115
TRIMMED L in(mm)
0.45 (11.43)
0.40 (10.16)
0.35 (8.89)
0.30 (7.62)
0.25 (6.35)
0.20 (5.08)
0.15 (3.81)
0.10 (2.54)
0.115 (2.92)
NOTE: Use appropriate code numbers for
other trimmed lengths not listed.
(e.g. Q14 for 0.14 inch (3.55 mm))
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 07.09.14
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U CRYSTAL
AB
OUTLINE DRAWING:
Insulator Tab
For Option I
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
Vinyl Sleeve
For Option V
Dimensions: inch (mm)
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 07.09.14
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
HC49/U CRYSTAL
AB
OUTLINE DIMENSION CONTD...
Metal Jacket Formed Leads
For Option MJ
Pb
RoHS/RoHS II Compliant
11.5 x 5.0 x 13.46mm
| | | | | | | | | | | | | | |
T 1,000 pcs/reel
Dimensions: mm
TAPE & REEL:
T: 1,000 pcs/reel
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where
component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and
authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO 9001:2008
ISO 9001 / QS 9000
CERTIFIED
Revised: 07.09.14
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
Last time I shared a local clock, but my friend thought it was not fashionable, so after thinking about it, I decided to make a world clock to support the scene, which can be regarded as a small expan...
Event Description
From December 12 to December 31, 2019, watch the TI training course highlights, record your thoughts and gains, or comment on the video in the video comment area , and reply with a s...
25. Which peripherals can the CLA access directly? The following shows the peripherals that the CLA can access on the 2803x and 2805x. Additional peripherals are available on some devices. Please refe...
1 CAN Bus Overview CAN, the full name of which is "Controller Area Network", is one of the most widely used fieldbuses in the world. In the early 1980s, the German company Bosch developed the...[Details]
The following is mainly an introduction for beginners. I think intermediate and advanced players don’t need to read it. Maybe some MCU beginners have some doubts about how to smoothly convert the as...[Details]
Overview of Power Supply Development
The power supply industry is the energy-based industry of the entire electronics industry. With the diversification of power electronic equipment and the en...[Details]
Intel has a four-year plan to master the fifth-generation CPU process. The starting point is the 12th-generation Core. Currently, the 12th- and 13th-generation Core have been launched. The process is...[Details]
In recent years, TWS (True Wireless Stereo) has been rapidly rising in the headphone market. Now, users no longer have to worry about the tangled headphone wires when using streaming devices. True ...[Details]
A major challenge in automotive design is protecting electronic devices (such as control units, sensors, and infotainment systems) from harmful surge voltages , transient voltages, ESD, and noise that...[Details]
According to the Weibo whistleblower @数码闲聊站, the vivo X60 standard version will soon launch a curved screen version. The parameters of this model are similar to the standard version. The diffe...[Details]
Introduction As a new type of instrument, vortex flowmeter is widely used in flow measurement, but there are many problems in installation. This article explains several issues that should be paid at...[Details]
The difference between ordinary functions and callback functions is that ST encapsulates interrupts and provides APIs to users, which are interrupt functions of the standard library. Calling a normal...[Details]
Analog Devices announces €630 million investment in next-generation semiconductor R&D and manufacturing facility in Limerick • New facilities will support cutting-edge applications such as digital...[Details]
Looking at the current situation, security robots have become a special new force in the security industry, and have begun to change the existing prevention and control mode in certain scenarios. The...[Details]
0 Introduction
Electromagnetic environment testing is a basic work of electromagnetic spectrum management. It is widely used in various aspects of electromagnetic spectrum management, such as ...[Details]
According to the U.S. Energy Information Administration (EIA), the United States is expected to deploy 10GW of battery energy storage systems in the next two years, of which more than...[Details]
1. When I used the positive to negative voltage conversion chip recently, I found that the output negative voltage was insufficient. When the load was disconnected, the voltage was restored. I began...[Details]
According to a Gartner survey of 451 senior technology leaders in the second quarter of 2024, 57% of chief information officers (CIOs) said they were responsible for leading their company's artif...[Details]