DC/DC Converter; Product Weight (grams): 14; Input voltage min (V): 36; Input voltage max (V): 75; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Dual; Output Power (W): 3; Max Output current (A): ±0.3; Efficiency (%): 82; Max Capacitive load (µF): ±2200; Package type: DIP24; Mounting: PCB; W (in): 0.8; L (in): 1.24; H (in): 0.4; W (mm): 20.3; L (mm): 31.6; H (mm): 10.2; Min Operating temperature: -40; Max operating temperature (°C): 85; Isolation (VDC): 1500; EMC compliance 1: EN 55022 Class A; EMC compliance 2: EN 55022 Class B; Case material: Plastic (flammability to UL 94V-0) ; Application 4 (building automation/IoT): 1; Application 5 (Industrial): 1; MTBF (h): 1000000; Derating : 85; Voltage Accuracy (%): ±3; Line Regulation (% of Vin): ±0.2; Load Regulation %: ±0.2; Ripple & Noise (mV p-p): 80; Switching Frequency typ (KHz): 200; Short circuit protection: Continuous
DC/DC Converter; Product Weight (grams): 14; Input voltage min (V): 36; Input voltage max (V): 75; Output voltage min: 5; Output voltage max: 5; Output voltage dual assymetric (y/n): Dual; Output Power (W): 3; Max Output current (A): ±0.3; Efficiency (%): 82; Max Capacitive load (µF): ±2200; Package type: DIP24; Mounting: PCB; W (in): 0.8; L (in): 1.24; H (in): 0.4; W (mm): 20.3; L (mm): 31.6; H (mm): 10.2; Min Operating temperature: -40; Max operating temperature (°C): 85; Isolation (VDC): 1500; EMC compliance 1: EN 55022 Class A; EMC compliance 2: EN 55022 Class B; Case material: Plastic (flammability to UL 94V-0) ; Application 4 (building automation/IoT): 1; Application 5 (Industrial): 1; MTBF (h): 1000000; Derating : 85; Voltage Accuracy (%): ±3; Line Regulation (% of Vin): ±0.2; Load Regulation %: ±0.2; Ripple & Noise (mV p-p): 80; Switching Frequency typ (KHz): 200; Short circuit protection: Continuous
EN 55022, Class B, with external filter & EN 55024: 2010
IEC 61000-4-2, Contact ±4KV/Air ±8KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
IEC 61000-4-4, ±2KV, Criteria B, with external filter
IEC 61000-4-5, ±2KV, Criteria B, with external filter
IEC 61000-4-6, 3Vrms, Criteria A
IEC 61000-4-29, 0-70%, Criteria B
Standards
Pin Out Specifications
Pin
2
3
9
10
11
14
15
16
22
23
Dimensions
31.60
(1.24)
0.50
(0.02)
Single
-V Input
-V Input
N.C.
N.C.
N.C.
+V Output
N.C.
-V Output
V+ Input
V+ Input
Dual
-V Input
-V Input
Common
N.C.
-V Output
+V Output
N.C.
Common
+V Input
+V Input
22.86
(0.90)
2
3
9 10 11
15.24
(0.60)
5.08
(0.20)
20.30
(0.80)
Bottom View
23 22
2.54
(0.10)
16 15 14
N.C.: not connected
10.20
(0.40)
Printed Face
Built-in Stand-offs to
ease PCB cleaning
www.aimtec.com
F 051e R7
Tel: +1 514 620 2722
3 of 4
4.10
(0.16)
All dimensions are typical: millimeters (inches)
Pin Diameter: 0.50 ± 0.10 (0.02 ± 0.004)
Pin Pitch Tolerance: ± 0.35 (±0.014)
Case Tolerance: ± 0.5 (±0.02)
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AM3T-PNZ
Filtering Single output
Filtering Dual output
3 Watt | DC-DC Converter
External capacitors
Vin
(VDC)
5 & 12
24 & 48
Cin)
(uF)
100
10-47
Cout
(uF)
10
10
EMC Recommended Circuit
Single Output
+ Vin
FUSE
C3
+
+Vout
LDM
C4
MOV
C1
C2
DC
DC
- Vin
Optional Surge
Circuit
Optional Filter
Circuit
- Vout
CY1
Model
C1 & C2
C3
1000µF / 16V
1000 µF / 25V
330 µF / 50V
330 µF / 100V
C4
10 µF
LDM
12 µH
MOV
-
S14K25
S14K35
S14K60
CY1
1 nF /2KV – 1500VDC models
1 nF/3KV – 3000VDC models
5 Vin
4.7 µF / 50V
12 Vin
4.7 µF / 50V
24 Vin
4.7 µF / 50V
48 Vin
4.7 µF / 100V
Note: Fuse is user selectable
Derating
Free Air Convection
85º C
100
Output Power (%)
80
60
Safe Operating Area
40
20
0
- 40
- 20
0
20
40
60
80
85
100
105
Ambient Temperature
º C
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.