FLUKE-177 Z540 W/DATA

Description
digital multimeters trms multimeter z540 W/data
CategoryTopical application    Test and measurement   
File Size48KB,3 Pages
ManufacturerFluke
Websitehttps://www.fluke.com
Environmental Compliance
Download Datasheet Parametric Compare View All

FLUKE-177 Z540 W/DATA Overview

digital multimeters trms multimeter z540 W/data

FLUKE-177 Z540 W/DATA Parametric

Parameter NameAttribute value
ManufactureFluke
Product CategoryDigital Multimeters
RoHSYes
ProducMultimeters
TypeHand Held
Unit Weigh420 g
Page 1 of 3, Document #2155
170 Series True-rms DMMs
Extended Specifications
©2000 Fluke Corporation
Rev. A-11/2000
Fluke 170 Series
True-rms Digital Multimeter
Extended Specifications
Model Differences
(all other specifications are the same for each model)
Feature
175
Backlight
Temperature Measurement
Basic dc voltage accuracy
0.15%
0.09%
Model
177
179
0.09%
Nominal Specifications
Function
AC Voltage, True-rms
DC Voltage
Continuity
Resistance
Diode Test
Capacitance
AC Current, True-rms
DC Current
Frequency
Temperature (179 Only)
Basic dc voltage accuracy
Basic ac voltage accuracy
0.1 mV to 1000V
Beeper guaranteed on < 25
Ω,
guaranteed off > 250
Ω;
detects opens or shorts of 250
µs
or longer.
0.1Ω to 50.00 MΩ
2.400V
1 nF to 9999 uF
0.01 mA to 10.00A (20.00 A over-range for 30 seconds)
0.01 mA to 10.00A (20.00 A over-range for 30 seconds)
2 Hz to 50 kHz
-40 ºC to +400 ºC; -40 ºF to +752 ºF
0.15% (175)
1.0%
0.09% (177 & 179)
Absolute Range or Description
0.1 mV to 1000V (1 kHz)
Features
Feature
Digital Display
Analog Bargraph Display
Backlight (177 & 179 only)
HOLD & Auto HOLD
Description
6000 counts, updates 4 x second
33 segments, updates 40 x second
Automatically turns off after 2 minutes to save battery life
The timeout feature can be disabled with a power-up option
HOLD: freezes the display at the push of a button
Auto HOLD: Display holds present reading until it detects new stable input,
then the meter beeps and displays new reading
MIN MAX AVG
Manual or auto ranging
Fast continuity/open detection
Test lead alert
Power-up options
Closed-case calibration
Probe holders
Battery access door
High-impact overmold case
Minimum, maximum, and average reading memory
In auto range, the meter selects the range with the best resolution for
the present measurement value
The beeper sounds with a stretched pulse for opens or shorts as
brief as 250
µs
The message “LEAd” appears briefly on the display when the rotary switch
is moved to or from any
A
(Amps) position
(1) Turn on all LCD segments, (2) Disable beeper, (3) Disable sleep mode,
(4) Enable smoothing, (5) Disable backlight timeout (Models 177 & 179 only)
No internal adjustments needed
The instrument comes with built-in probe holders for probe storage and
for convenience when making measurements
Battery replacement without voiding calibration
Integrated overmolded protection provides superior impact protection for
your meter

FLUKE-177 Z540 W/DATA Related Products

FLUKE-177 Z540 W/DATA FLUKE-175-NIST W/O DATA FLUKE-179-NIST W/O DATA FLUKE-179 ESFP FLUKE-177 ESFP
Description digital multimeters trms multimeter z540 W/data digital multimeters trms multimeter nist W/O data digital multimeters trms dmm nist cal cert W/O data digital multimeters trms multimeter digital multimeters trms multimeter
Manufacture Fluke Fluke Fluke - -
Product Category Digital Multimeters Digital Multimeters Digital Multimeters - -
RoHS Yes Yes Yes - -
Produc Multimeters Multimeters Multimeters - -
Type Hand Held Hand Held Hand Held - -
Unit Weigh 420 g 420 g 420 g - -
【ST NUCLEO-H743ZI Review】(2) First experience with Ethernet testing
[i=s]This post was last edited by bigbat on 2019-2-22 11:52[/i] After lighting up the LED in the previous article, start testing Ethernet. [color=#0000ff]The board is provided by ST, [url=https://www....
bigbat stm32/stm8
What is TV_RM? What is its function?
This is the 24V input power processing part on a microcontroller circuit board. What is TV_RM in the red circle? Is it a TVS tube? After being connected in parallel with the resistor, both ends are co...
frily Analog electronics
[TI Course] Is there any problem with Figure 4.3.2 of 4.3.1 Differential Amplifier?
Basic knowledge of electronic circuits lecture 424.3.1 In the differential amplifier , is there a problem with Figure 4.3.2? From the above formula 4.3.2, we can see that R1 and the output voltage are...
sunm_wang450 Analogue and Mixed Signal
[Lazy self-care fish tank control system] Production of BLE_MESH fish tank light
[Lazy self-care fish tank control system] Production of BLE_MESH fish tank lightFish tank lights are an integral part of the fish tank system. Through the lights, we can see the fish better and highli...
蓝雨夜 onsemi and Avnet IoT Innovation Design Competition
MATLAB R2020a Complete Self-Study Guide
This book is aimed at beginner and intermediate readers of MATLAB. On the basis of introducing the MATLAB R2020a integrated environment, it provides a detailed introduction to the commonly used knowle...
arui1999 Download Centre
Buy an oscilloscope and get the essential analysis software 5-PWR for power engineers
It's the end of the month, and I would like to share with you an event[font=微软雅黑][size=3][font=微软雅黑][size=3] [/size][/font] Tektronix provides engineers with efficient tools to help you better locate ...
eric_wang Integrated technical exchanges

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号