EEWORLDEEWORLDEEWORLD

Part Number

Search

D4C-9160

Description
Basic/quick action/limit switch lsw sealed roller P lunger
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size754KB,23 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric View All

D4C-9160 Online Shopping

Suppliers Part Number Price MOQ In stock  
D4C-9160 - - View Buy Now

D4C-9160 Overview

Basic/quick action/limit switch lsw sealed roller P lunger

D4C-9160 Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryBasic/Snap Action/Limit Switch
RoHSyes
typeLimi
Enclosed Switch
D4C
Compact Limit Switch That's Also
Thin and Highly Sealed
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
VCTF cables with CE marking.
(Applicable only to standard models.)
Be sure to read
Safety Precautions
on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
Standard Models
Pre-wired Models
Weather-resistant Models
D4C-@@@
(1) (2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
D4C-@0@@-@@@@@@
(1)
(2)
(3)
(4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
COM
NC
NO
Connector
3
2
4
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1
Electronic computing software
A very old small software, which was often used before. It is very useful for hardware engineers. Someone should have posted it on the forum. I will post it again....
xiaomizia Power technology
MCO (PA8) does not output waveform during DEBUG. What is the reason?
I turned on several clock sources, and the PA8 port was also configured as auxiliary function output, [/size][/font][/size][/align][align=left][size=14px][img=424,0]http:// www.stmcu.org.cn/module/for...
csz9981 stm32/stm8
Patch reverse check
Can anyone help me figure out what this 5-pin patch is? There are two dots under W1 horizontally, and a P vertically....
半瓶水_1001 PCB Design
EEWORLD University ---- Control system of 100 quantum bits
100-qubit control system : https://training.eeworld.com.cn/course/4867...
EE大学堂 Test/Measurement
The difference between USART, USI, USCI and eUSCI serial communication modules in MSP430 microcontroller (updated on March 4, 2019)
[i=s]This post was last edited by tiankai001 on 2019-3-4 16:56[/i] [b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]tiankai001[/size]. If you need to reprint or use i...
tiankai001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号