Embedded Power for
Business-Critical Continuity
NFS110 Series
Single and
quad output
Rev.02.16.07
NFS110 Series
1 of 4
Total Power:
80 - 110W
Input Voltage: 85 - 264VAC
120 - 370VDC
# of Outputs: Single, quad
Special Features
• 7.0 x 4.25 x 1.8 inch package
• Overvoltage and
short circuit protection
• 110 W with 20 CFM
• Adjustable outputs
• EN55022, EN55011
conducted emissions level B
• UL, VDE and CSA
safety approvals
• CE mark
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/
IEC950/IEC1010
File No. 10401-3336-0213
Licence No. 40014677
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
The NFS110 series is a 110 W universal input ac-dc power supply
on a 7 x 4.25 inch card. The NFS110 series has four single and
three quad output models and has proven itself to be highly
reliable and versatile product for a wide range of communication
and industrial applications, with a very high peak current
capability on each output for drive and motor applications. The
NFS110 provides 80 W of output power with free air convection
cooling which can be boosted to 110 W with 20 CFM of air.
Standard features include overvoltage and short circuit
protection. The series, with full international safety approval and
the CE mark, meets conducted emissions EN55022 level B. The
NFS110 series is designed for use in low power data networking,
computer, telecom and industrial applications such as servers,
thermal printers, storage devices, vending machines and POS
equipment.
Embedded Power for
Business-Critical Continuity
Specifications
All specifications are typical at nominal input, full load at 25
°
C unless otherwise stated
Rev.02.16.07
NFS110 Series
2 of 4
OUTPUT SPECIFICATIONS
Voltage adjustability
+5.1 V o/p on multi’s
5.1 V single output
12 V single output
15 V single output
24 V single output
LL to HL, FL
All outputs on all units
At turn-on
All outputs
Multi o/p 5.1 V only
5.1 V single
12 V single
15 V single
24 V single
Primary power
limited
(See Note 13)
±3.0%
±3.0%
12-14 V
15-18 V
24-30 V
±0.1% max.
0%
±0.02%/°C
6.25 V ±0.75 V
6.25 V ±0.75 V
15.75 V ±1.0 V
22 V ±1.5 V
33 V ±2.5 V
Pin max. 160 W
Pout min. 110 W
0A
Burst mode operation
GENERAL SPECIFICATIONS
Hold-up time
110 Vac @ 80 W
110 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 110 W
Multiple outputs
+5.1 V single
12 V and 15 V singles
24 V single
Input/output
Input/chassis
At 100 Watts output
At zero load
35 ms
17 ms
140 ms
100 ms
70% typical
70% typical
72% typical
75% typical
3000 Vac
1500 Vac
20-70 kHz
100-250 kHz
Efficiency
Line regulation
Overshoot/undershoot
Temperature coefficient
Overvoltage protection
Isolation voltage
Switching frequency
Approvals and
standards
(See Note 12)
Weight
MTBF (See Note 9)
Output power limit
Minimum output current
Short circuit protection
INPUT SPECIFICATIONS
Input voltage range
Input frequency range
Input surge current
Safety ground
leakage current
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
VDE0805, EN60950, IEC950
IEC1010, UL1950
CSA C22.2 No. 950
Singles
Multiple outputs
MIL-HDBK-217E
550 g (19.4 oz)
600 g (21.2 oz)
125,000 hours
ENVIRONMENTAL SPECIFICATIONS
85-264 Vac
120-370 Vdc
47-440 Hz
230 Vac
110 Vac, 50 Hz
230 Vac, 50 Hz
35 A
0.2 mA, max.
0.4 mA, max.
Thermal performance
(See Notes 9, 10)
Operating, see curve
0 °C to +70 °C
Non-operating
–40 °C to +85 °C
0 °C to +50 °C,
80 W
amb. convection cooled
+50 °C to +70 °C,
Derate 2 W/°C
amb. convection cooled
0 °C to +50 °C,
110 W
20 CFM forced air
+50 °C to +70 °C,
Derate
20 CFM forced air
2.75 W/°C
Peak, 0 °C to +50 °C,
110 W
max. 60 seconds
Non-condensing
Operating
Non-operating
5-500 Hz
5% to 95% RH
10,000 feet max.
40,000 feet max.
2.4 G approx.
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Level B
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 1
Relative humidity
Altitude
Vibration (See Note 11)
Embedded Power for
Business-Critical Continuity
Specifications Contd.
OUTPUT
VOLTAGE
+5.1 V
+12 V
–12 V
–5 V
+5.1 V (I
A
)
+24 V (I
B
)
(6)
+12 V
–12 V
+5.1 V
+15 V
–15 V
–5 V
5.1 V
12 V
15 V
24 V
Notes
1
2
3
4
5
6
Convection cooled, 80 W maximum.
Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 μF capacitor.
Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings.
To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the
following load condition must be true: I
A
/ I
B
≤ 5, where:
I
A
= +5.1 V output current, and
I
B
= +24 V output current
The +24 V output will maintain ±5.0% regulation under the following additional
condition: I
A
≤ 5 A.
Single output models have floating outputs which may be referenced as either
positive or negative. Higher voltage supplies may be adjusted over a wide
output voltage range, as long as the total output power does not exceed 80
Watts (natural convection) or 110 Watts (forced air).
Power fail detect not available on single output models.
Derating curve is application specific for ambient temperatures >50 °C, for
optimum reliability no part of the heatsink should exceed 90 ºC and no
semiconductor case temperature should exceed 100 ºC.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
Three orthogonal axes, random vibration, 10 minute test for each axis.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Artesyn Technologies recommends a minimum load of 11 W to achieve the
design MTBF. See the derating curve on page 3.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
Rev.02.16.07
NFS110 Series
3 of 4
OUTPUT CURRENTS
MAX
(1)
8A
4.5 A
0.5 A
0.5 A
8A
3.5 A
4.5 A
0.5 A
8A
4A
0.5 A
0.5 A
16 A
7A
5A
3.5 A
PEAK
(2)
20 A
9A
1.5 A
1.5 A
20 A
4.5 A
9A
1.5 A
20 A
7.5 A
1.5 A
1.5 A
22 A
9A
7.3 A
4.5 A
FAN
(3)
10 A
5A
1A
1A
10 A
4.5 A
5A
1A
10 A
5A
1A
1A
20 A
9A
7.3 A
4.5 A
RIPPLE
(4)
50 mV
120 mV
120 mV
50 mV
50 mV
240 mV
120 mV
120 mV
50 mV
150 mV
150 mV
50 mV
50 mV
120 mV
150 mV
240 mV
TRANSIENT RESPONSE
NFS110-7601PJ
TOTAL
REGULATION
(5)
±2.0%
±3.0%
±3.0%
±3.0%
±2.0%
+10/–5.0%
±3.0%
±3.0%
±2.0%
±3.0%
±3.0%
±3.0%
±2.0%
±2.0%
±2.0%
±2.0%
MODEL NUMBERS
(13,14,F)
NFS110-7601PJ
NFS110-7602PJ
(6)
NFS110-7604PJ
NFS110-7605J
(7,8)
NFS110-7612J
(7,8)
NFS110-7615J
(7,8)
NFS110-7624J
(7,8)
+5.1 V (7.5 A to 10 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
150 mV peak,
1 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
150 mV peak,
1 ms recovery
300 mV peak,
1 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
150 mV peak,
1 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
250 mV peak,
1 ms recovery
360 mV peak,
1 ms recovery
450 mV peak,
1 ms recovery
720 mV peak,
1 ms recovery
NFS110-7602PJ
+5.1V (7.5 A to 10 A)
+24 V (1.5 A to 3 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
7
8
9
10
11
12
13
14
15
NFS110-7604PJ
+5.1 V (7.5 A to 10 A)
+15 V (2.5 A to 5 A)
-15 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
NFS110-7605J
NFS110-7612J
NFS110-7615J
NFS110-7624J
+5.1 V (10 A to 20 A)
+12 V (4.5 A to 9 A)
+15 V (3.65 A to 7.3 A)
+24V (2.25 A to 4.5 A)
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS110 Series
4 of 4
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.