Features ....................................................................................................................................................................................... 1
Ordering Information .................................................................................................................................................................... 2
LVPECL and FlexSwing Termination .................................................................................................................................. 17
LVDS, Supply Voltage: 1.8 V
±5%,
2.5 V ±10%, 3.3 V ±10%, 2.25 V to 3.63 V, 1.71 V to 3.63 V ...................................... 18
HCSL, Supply Voltage: 1.8 V
±5%,
2.5 V ±10%, 3.3 V ±10%, 2.25 V to 3.63 V, 1.71 V to 3.63 V ...................................... 18
Low-power HCSL, Supply Voltage: 1.8 V
±5%,
2.5 V ±10%, 3.3 V ±10%, 2.25 V to 3.63 V, 1.71 V to 3.63 V.................... 18
Dimensions and Patterns ― 2.0 x 1.6 mm x mm ....................................................................................................................... 19
Dimensions and Patterns ― 2.5 x 2.0 mm x mm ....................................................................................................................... 20
Dimensions and Patterns ― 3.2 x 2.0 mm x mm ....................................................................................................................... 21
Revision History ......................................................................................................................................................................... 22
Rev 0.52
Page 3 of 23
www.sitime.com
SiT9375
Low Jitter Differential XO for Standard Frequencies
Electrical Characteristics
ADVANCED
All Min and Max limits in the Electrical Characteristics tables are specified over operating temperature and rated operating
voltage with standard output termination shown in the termination diagrams. Typical values are at 25°C and nominal
supply voltage.
Table 3. Electrical Characteristics – Common to All Output Signaling Types
Parameter
Output Frequency Range
Frequency Stability
Symbol
f
F_stab
–
Min.
Typ.
Max.
Unit
MHz
ppm
Condition
Refer to frequencies listed in
Ordering Information
section.
Inclusive of initial tolerance, operating temperature, rated power
supply voltage, load variation of 15 pF
±
10%, and 10 years
aging at 25°C
Inclusive of initial tolerance, operating temperature, rated power
supply voltage, load variation of 15 pF
±
10%, and first year aging
at 25°C
Ambient temperature of 25°C
Extended commercial, ambient temperature
Industrial, ambient temperature
Ambient temperature
Extended industrial, ambient temperature
Voltage-supply order code “YY”
Voltage-supply order code “XX”
Voltage-supply order code “18”.
Contact SiTime
for 1.5 V
Voltage-supply order code “25”
Voltage-supply order code “33”
Pins 1 and 2 for OE and SE, respectively
Pins 1 and 2 for OE and SE, respectively
Pins 1 and 2 for OE and SE, respectively
See
Figure 5
and
Figure 7
Measured from the time Vdd reaches its rated minimum value
Measured from the time OE pin toggles to enable logic level to
the time clock pins reach 90% of swing. See
Figure 12
Measured from the time OE pin toggles to disable logic level to
the last clock edge. See
Figure 13
12 kHz to 20 MHz offset frequency integration bandwidth,
156.25 MHz
12 kHz to 20 MHz offset frequency range, 156.25 MHz
12 kHz to 20 MHz offset frequency range, 155.52 MHz
156.25 MHz
156.25 MHz
Frequency Range
Standard frequencies
–
±20
Frequency Stability
–
–
–
10 Year Aging
Operating Temperature Range
F_10y
T_use
–
-20
-40
-40
-40
Supply Voltage
Vdd
1.71
2.25
1.71
2.25
2.97
Input Voltage High
Input Voltage Low
Input Pull-up Impedance
Duty Cycle
Startup Time
Output Enable Time
Output Disable Time
VIH
VIL
Z_in
DC
T_start
T_oe
T_od
70%
–
–
45
–
–
–
–
–
–
±1
–
–
–
–
–
–
1.80
2.50
3.30
–
–
100
–
1
–
–
±25
±30
±50
–
+70
+85
+95
+105
ppm
ppm
ppm
ppm
°C
°C
°C
°C
V
V
V
V
V
Temperature Range
Supply Voltage
3.63
3.63
1.89
2.75
3.63
Input Characteristics
–
Vdd
30%
–
55
5
100+3 clock
cycles
100+3 clock
cycles
Vdd
kΩ
%
ms
ns
ns
Output Characteristics
Startup, OE and SE Timing
Jitter and Phase Noise
RMS Phase Jitter (random)
Spurious Phase Noise
RMS Period
Jitter
[1]
Jitter
[1]
T_phj
PN_spur_a
PN_spur_b
T_jitt_per
T_jitt_cc
Peak Cycle-to-cycle
–
–
–
–
–
200
-110
-80
1
6
–
–
–
–
–
fs
dBc
dBc
ps
ps
Note:
1. Measured according to JESD65B.
Rev 0.52
Page 4 of 23
www.sitime.com
SiT9375
Low Jitter Differential XO for Standard Frequencies
ADVANCED
Table 4. Electrical Characteristics – LVPECL
|
Supply voltages: 2.5 V
±10%,
3.3 V
±10%,
2.25 V to 3.63 V
Parameter
Current Consumption, Output
Enabled without Termination
Current Consumption, Output
Enabled with Termination 1
Current Consumption, Output
Enabled with Termination 2
Current Consumption, Output
Disabled without Termination
Current Consumption Output
Disabled with Termination 1
Current Consumption, Output
Disabled with Termination 2
OE Leakage Current
Symbol
Idd_oe_nt
Idd_oe_wt1
Idd_oe_wt2
Idd_od_nt
Idd_od_wt1
Idd_od_wt2
I_leak
Min.
–
–
–
–
–
–
–
Typ.
43
52
71
58
58
86
37
Max.
–
–
–
–
–
–
–
Unit
mA
mA
mA
mA
mA
mA
mA
Condition
Excluding load termination current
Including load termination current. See
Figure 15
for
termination
Including load termination current. See
Figure 18
for
termination
Excluding load termination current
Including load termination current. See
Figure 15
for
termination
Including load termination current. See
Figure 18
for
termination
OE = disable logic, DC termination, OUTP and OUTN held
The 2021 ZTE Government and Enterprise Cloud Network Ecosystem Summit was recently held at the Shangri-La Hotel in Nanjing. With the theme of "Building the Digital Economy and Win-Win Cloud Network E...[Details]
The U.S. Department of Commerce recently announced that it will launch an investigation into the U.S. semiconductor supply chain and defense industrial base in January 2024, "to support the United St...[Details]
According to a report by the Nikkei on February 25, Japan's declining competitiveness became increasingly apparent at an international academic conference related to semiconductors. According to th...[Details]
On January 15, WeChat iOS version ushered in the official version 8.0.17 update today. The 8.0.16 update can be traced back to October 29 last year, which is 2 and a half months ago. Since WeCh...[Details]
Why does the * symbol appear in the test report of Fluke DTX series? Why are the results of the same wire inconsistent on different test platforms? For questions related to Fluke and Netally, please ...[Details]
We have also verified more accurate figures. In fact, in 2019, the shipment of 5G mobile phones in the Chinese market has reached 13.77 million units. Combined with the data from the China A...[Details]
The function of the PLC automatic sequence is to control the equipment to work according to the pre-designed process flow. There are also several ways to write the process of the PLC automatic pro...[Details]
The code in iwdg.c is as follows: #include "iwdg.h" // Initialize independent watchdog //prer: frequency division number: 0~7 (only the lower 3 bits are valid!) rlr: automatic reload value, 0~0XFFF. ...[Details]
The next era of mobile phone charging is here. #Xiaomi launches its first self-developed wireless charging technology# At 10:30 this morning, Xiaomi released a charging method from the future: wi...[Details]
I have always created my own module files directly on the original project. Now, when I create a new project, various link errors appear (of course, I am talking about multi-file projects here, and s...[Details]
According to foreign media reports, well-known Apple whistleblower Mark Gurman said that Apple is stepping up internal testing of its first Mac Pro equipped with Apple Silicon chips in preparation fo...[Details]
First, let’s look at the two waveform diagrams, Figure 1 and Figure 2. In these two diagrams, the sampling frequencies when the signals are discretized are much larger than the frequency of the signa...[Details]
Gu Chunyuan, head of North Asia and China for the Discrete Automation and Motion Control business unit of ABB Group, a global electrical and automation giant, recently pointed out in an interview wit...[Details]
Using the energy storage characteristics of capacitors and inductors, high-frequency switching is performed through controllable switches (MOSFET, etc.), and the input electrical energy is stored i...[Details]
1. Background
Modbus and Profibus are two commonly used communication protocols in industrial control systems. They play an important role in the field of automation. Modbus is a serial commun...[Details]