EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS75AF36/JA

Description
switching power supplies 76w 36v 2.1A
CategoryPower/power management   
File Size535KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance
Download Datasheet Parametric View All

ZWS75AF36/JA Overview

switching power supplies 76w 36v 2.1A

ZWS75AF36/JA Parametric

Parameter NameAttribute value
ManufactureTDK-Lambd
Product CategorySwitching Power Supplies
RoHSYes
ProducSwitching Supplies
Open Frame/EnclosedOpen Frame
Output Power Rating76 W
Input Voltage85 VAC to 265 VAC
Number of Outputs1 Outpu
Output Voltage-Channel 136 V
Output Current-Channel 12.1 A
Commercial/MedicalCommercial
Length4.6 i
Width2.4 i
Heigh0.5 i
ApprovalsUL60950-1, EN60950-1
Dimensions4.6 in L x 2.4 in W
Unit Weigh250 g
ZWS-AF Series
50W to 150W Single Output Low Cost, Worldwide Use
Features
u
Universal Input (85 - 265VAC)
u
Power factor Corrected
u
Input transient protected
u
2 year warranty
u
High quality design
u
Peak Power capability
Key Market Segments & Applications
Specifications
Model
AC Input Voltage range
DC Input Voltage range
Input Current (Typ) (1)
Inrush Current
Power Factor (1)
Maximum Ripple and Noise
Temperature Coefficient
Overcurrent Protection (4)
Hold Up Time (Typ) (1)
Leakage Current
Remote On / Off
Operating Temperature
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
VAC
VDC
A
A
-
mV
-
-
ms
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
ZWS75AF
ZWS100AF
ZWS150AF
85-265VAC (47-63Hz)
120-370VDC
0.8/0.4
1.2/0.6
1.4/0.7
2.0/1.0
14/28 25°C Ambient, Cold Start
Meets EN61000-3-2 (0.99/0.95)
3.3 & 5V: 120mV; 12 to 24V: 150mV; 36 & 48V: 200mV
<0.02%/°C
>105% of Peak Current Capability
20ms
0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC
See installation manual (Not available with /A cover option)
Convection cooling - See table on page 2
0.7m/s air -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C (2)
-30° to +85°C
Operating: 30 - 90% RH, storage 10-95% RH
I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B
designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
210
290
380
500
55 x 26 x 195
55 x 32 x 222
62 x 35 x 222
75 x 40 x 222
Two Years
ZWS50AF
Notes:
(1) 100/200VAC
(2) ZWS150AF -10 to 60°C, derate linearly to 70% load from 50°C to 60°C
(3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35%
(4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds.
(5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input.
For New Designs, See ZWSBAF Series
1-800-526-2324 • www.us.tdk-lambda.com/lp/
1
Disclaimer: us.tdk-lambda.com/lp/legal.htm

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号