LG400M0120BP3-3025

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum, 400V, 20% +Tol, 20% -Tol, 120uF,
CategoryPassive components    capacitor   
ManufacturerYAGEO
Websitehttp://www.yageo.com/
Environmental Compliance
Download Datasheet Parametric View All

LG400M0120BP3-3025 Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 400V, 20% +Tol, 20% -Tol, 120uF,

LG400M0120BP3-3025 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid746285381
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance120 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
diameter30 mm
dielectric materialsALUMINUM (WET)
length25 mm
negative tolerance20%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-25 °C
Package formSnap-in
method of packingBulk
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)400 V
ripple current750 mA
YAGEO CORPORATION
ELECTROLYTIC CAPACITORS
Large Can Aluminum
Electrolytic Capacitors
LG
[ For General ]
For Printed Circuit Board High-Performance Aluminum Electrolytic Power Supply
Input and Output Filter Capacitors
ELECTRICAL CHARACTERISTICS
Operating Temperature Range -40 to +105°C
Rated Voltage Range
Rated Capacitance Range
Capacitance Tolerance
Leakage Current
6.3 to 100VDC
560 ~ 82000µF
±20% at 120Hz, 20°C
I = 0.02CV, L = 20m/m, I = 0.03CV or 3mA whichever is smaller.
(After 5 Minutes Application of DC Working Voltage at 20°C)
I = Leakage Current (µA), C = Nominal Capacitance (µF),V = Rated Voltage (V)
Dissipation Factor (tanδ)
Rate Voltage (V)
D.F. (%)
Low Temperature Stability
Impedance Ratio (Max.)
MULTIPLIER FOR RIPPLE CURRENT
Frequency Coefficient
FREQUENCY (Hz)
6.3~100V
160~250V
315~450V
50
60
120 1K
10K
Endurance
0.88 0.90 1.00 1.15 1.16
0.85 0.88 1.00 1.15 1.20
0.88 0.90 1.00 1.10 1.15
6.3
60
10
55
16
55
25
45
35
35
50
30
63-100 160-400 450
25
15
20
-25 to +105°C
160 to 450VDC
47 ~ 2200µF
DESCRIPTION
Endurance : 105°C 2000 hours, higher temperature
than LH.
Ideally suitable for using in switching power supplies
and other industrial / commercial applications.
Measurement frequency: 120Hz
Rated Voltage (V)
Z(-25°C) / Z(20°C)
Z(-40°C) / Z(20°C)
6.3~16 25
4
15
3
10
35
3
8
50~63
2
6
80~10 160~400 450
2
5
4
-
8
-
After the rated voltage and rated ripple current have been applied at 105°C
for 2000 hours, the capacitors shall meet the following requirements.
(a)
Capacitance Change:
±20% of the Initial Value
(b)
Dissipation Factor:
200% of the Initial Specified Value
(c) Leakage Current:
the Initial Specified Value
Shelf Life
After having been placed at 105°C without voltage applied for 1000 hours,
the capacitors shall meet the same requirements as Endurance.
DIAGRAM OF DIMENSIONS
Location of P.C.B. Holes
Vinyl Sleeve
0.9
±
0.1
10
±
0.5
2mm x 2
3.0
0.8+0.2 /-0.1
Botton Plate
Negative
Unit: mm
10
±
0.5
5.8
±
1.0
1.5+0.2 /-0.1
Safety Device
L+2 Max.
5.8
±
0.1
D
±
1
Make a development board to play with MicroPython
[i=s]This post was last edited by sunhaoqin1 on 2020-3-20 19:37[/i]I have always wanted to make a development board, and this time I stayed at home and started thinking about it. For the CPU, I will c...
sunhaoqin1 MicroPython Open Source section
[GD32E503 Evaluation] IAR Environment Porting FreeRTOSV202012.00
[i=s]This post was last edited by superstar_gu on 2021-1-27 09:49[/i]2.5 GD32E503V-EVAL development board transplantation FreeRTOS system2.5.1 OverviewDevelopment board: GD32E503V-EVAL development boa...
superstar_gu Domestic Chip Exchange
Last 2 days to register for ADI live broadcast | New ways to play with car audio system solutions! ADI experts will give you tips!
1. New functions and new scenarios for in-car audio are emerging one after another. Which ones are the most popular and practical? 2. What specific requirements does the new function put forward for t...
EEWORLD社区 Automotive Electronics
Last day! TE Smart Meter Training Camp, unlocking all products, technologies, and markets! A 50-yuan JD card is waiting for you
Smart meters are an important part of today’s smart grid. The role of smart grid is more than just power generation and distribution. It is an ecosystem built by IoT connected technologies and communi...
EEWORLD社区 Industrial Control Electronics
The problem of "ground" on both sides of the single-ended flyback power supply transformer
The simplified schematic diagram of the single-ended flyback switching power supply, the input voltage is 120-150VAC, as shown in the figure During the debugging process, if you want to observe the se...
shaorc Power technology
Help "There is nothing in the browse of AD9 package manager"
As shown in the figure:...
biu12138biu PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号