EEWORLDEEWORLDEEWORLD

Part Number

Search

M5266-10000Q-350BS

Description
Pressure Sensor
CategoryThe sensor   
File Size299KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

M5266-10000Q-350BS Overview

Pressure Sensor

M5266-10000Q-350BS Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145015036629
Reach Compliance Codeunknown
Maximum accuracy(%)0.25%
Other featuresIP65, REVERSE POLARITY PROTECTION, SHORT CIRCUIT PROTECTION
shellSTAINLESS STEEL
Maximum working current5 mA
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
Output range0-5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port typeM10X1.0MM, ISO 6149-2
Maximum pressure range5076.32 Psi
Minimum pressure range
Pressure sensing modeSEALED
Response time2000 µs
Sensor/temperature sensor typePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage30 V
Minimum supply voltage8 V
Termination typeCONNECTOR
M5200
Industrial Pressure Transducer
SPECIFICATIONS
Wide Temperature Range
Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless-Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Compound
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.25% Accuracy
±1.0% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The M5200
pressure transducers from the Microfused line of MEAS,
with their modular design, offer maximum flexibility for different
configurations. This latest series sets a new price performance
standard for demanding commercial and heavy industrial applications.
This series is suitable for measurement of liquid or gas pressure, even
for difficult media such as contaminated water, steam, and mildly
corrosive fluids.
The wetted material is made of either 17-4 PH or 316L stainless steel
and the transducer’s durability is excellent with no welds or organics
exposed to the pressure media. The M5200 is weatherproof and
exceeds the latest heavy industrial CE requirements including surge
protection. The circuit is protected from reverse wiring at input and
short circuit at output.
This product is geared to the OEM customer for low to mid volumes.
MEAS stands ready to provide a custom design of the M5200 where
the volume and application warrants. Additional configurations not
listed are either available or possible. Please inquire for further
information.
APPLICATIONS
Industrial Process Control and Monitoring
Advanced HVAC Systems
Refrigeration Systems
Automotive Test Stands
Off-Road Vehicles
Pumps and Compressors
Hydraulic/Pneumatic Systems
Agriculture Equipment
Energy Generation and Management
SENSOR SOLUTIONS
///M5200
08/2020
Page 1
Do you know the two technologies that help the Internet of Things during the COVID-19 pandemic?
As the COVID-19 pandemic has forced more people to work from home, the role of the Internet of Things has become increasingly important. However, the Internet of Things is provided through competing n...
alan000345 RF/Wirelessly
Play board + simple TMS320F28035 development board
[i=s]This post was last edited by ccmj4708 on 2020-2-16 15:31[/i]During the Spring Festival, I had a lot of free time. I wanted to use this time to learn about TI's DSP chip, model TMS320F28035. This ...
ccmj4708 Special Edition for Assessment Centres
Principle of the hardware debounce circuit for buttons
Why do we need to debounce buttons?Key debounce The switch used for the common keys is a mechanical elastic switch. When the mechanical contacts are opened and closed, due to the elastic effect of the...
可乐zzZ stm32/stm8
Prize-winning live broadcast: TI low-power MCU products and Zigbee wireless solutions video playback summary!
Prize-winning live broadcast: TI low-power MCU products and Zigbee wireless solutions video playback summary!Session 1: MSP430 low-power analog peripherals enable portable home healthcare productsSess...
EEWORLD社区 TI Technology Forum
About CAN communication
Communication - combined with the book, there are the following contents: Digital logic of CAN communication, implicit level 1, dominant level 0CAN communication frames are divided into data frames, r...
fish001 DSP and ARM Processors
How to add Fourier algorithm to measure body temperature and pulse in stc89c52? How to use algorithm to analyze the results after getting it?
The graduation project topic is a body temperature and pulse measurement system based on a single-chip microcomputer. Please tell me how to add Fourier algorithm to measure body temperature and pulse,...
哈喽摩托 Medical Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号