Part Number

Search

T496D686K016ZC6210

Description
Tantalum Capacitor, Polarized, Tantalum (dry/solid), 16V, 10% +Tol, 10% -Tol, 68uF, 2917
CategoryPassive components    capacitor   
File Size2MB,21 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

T496D686K016ZC6210 Overview

Tantalum Capacitor, Polarized, Tantalum (dry/solid), 16V, 10% +Tol, 10% -Tol, 68uF, 2917

T496D686K016ZC6210 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Objectid1308306858
package instruction, 2917
Reach Compliance Codenot_compliant
ECCN codeEAR99
capacitance68 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (DRY/SOLID)
ESR400 mΩ
high2.8 mm
JESD-609 codee0
length7.3 mm
negative tolerance10%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Plastic, 7 Inch
polarityPOLARIZED
positive tolerance10%
Rated (DC) voltage (URdc)16 V
GuidelineMIL-PRF-55365
size code2917
Terminal surfaceTin/Lead (Sn/Pb)
width4.3 mm
Tantalum Surface Mount Capacitors – High Reliability
T496 Series Fused Commercial Off-The-Shelf (COTS)
MnO
2
and DLA Drawing 04053
Overview
The T496 Series Commercial Off-The-Shelf (COTS) with a built-
in fuse design provides excellent protection from short circuit
conditions in applications where damaging high fault currents
exist. This series meets the MIL–PRF–55365 requirements
and is suitable for use in high reliability applications, incorporating
an intensive testing and screening protocol that is customizable
depending on specific customer requirements. The T496 COTS
Series is available in standard and low ESR.
Benefits
Meets or exceeds EIA standard 535BAACC
Halogen-free epoxy
Patented fuse assembly which protects against short circuit mode
DLA Drawing 04053 Available*
Established Reliability Weibull Options B, C, or D
100% surge current testing options per MIL–PRF–55365 available
Capacitance values of 0.15 µF to 470 µF
Voltage rating of 4 – 50 VDC
Fuse actuation, 25˚C: within 1 second at fault currents of
4 amps and higher
Continuous current capability of 0.75 amps
Post actuation resistance, 25˚C: 10 MΩ, minimum
Test tabs on side of case bypass the capacitor element to allow
direct testing of the fuse assembly
RoHS Compliant (100% Sn) and SnPb terminations available
Standard termination SnPb
Operating temperature range of -55˚C to +125˚C
MSL Level 1
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
* Defense Logistics Agency (DLA), previously identified as DSCC
Applications
Typical applications include decoupling and filtering in computing, telecommunications, defense, and industrial end applications
requiring built-in fuse capability.
Environmental Compliance
RoHS Compliant (6/6) according to Directive 2002/95/EC when ordered with 100% Sn solder.
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2062_T496_COTS • 10/14/2015
1
MSP430 system clock ACLK, MCLK, SMCLK
The MSP430 basic clock module contains the following three clock input sources. 1. 4 clock oscillator sources1. LFXT1CLK: external crystal or clock 1 low frequency clock source low frequency mode: 327...
fish001 Microcontroller MCU
Controlled by "Playpad" + Siri + shortcut commands + XCC3200 (MQTT)
Some time ago, a "shortcut command" was added to the mobile phone system update. I also saw others using shortcut commands to control the ESP8266 output. This is indeed more suitable for us electronic...
蓝雨夜 Special Edition for Assessment Centres
msp430f5529 dual output pwm wave
#include msp430.hextern unsigned int period,period1;int pwm1(period,period1) adjust duty cycle{P2DIR |= BIT0+BIT5;// P2.0 and P2.1 outputP2SEL |= BIT0+BIT5;// P2.0 and P2.1 options selectTA1CCR0 = 100...
火辣西米秀 Microcontroller MCU
Why should a DC-DC converter be used as close to the point-of-load (POL) power supply as possible?
Efficiency and accuracy are two major advantages, but implementing POL conversion requires careful attention to regulator design.Proximity to the source. This is one of the best ways to improve the vo...
wangerxian Power technology
Some subway stations in London have codes on their steps!
[size=5][color=#000000][backcolor=lightblue]The designer of the London Underground steps may be a programmer... [/backcolor][/color][/size][backcolor=lightblue][font=Arial, "][size=5][color=#000000]So...
qwqwqw2088 Talking

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号