ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw
Tel:+886-2-29180118
Fax:+886-2-29181465
We Supply the Power Customers Need
ISO9001
PRL1201 SERIES 180W to 400W AC TO DC ACTIVE PFC SWITCHING
POWER SUPPLY SPECIFICATION
FEATURES:
◆
400W convection cooling with 1U height
◆
Design meets IEC/EN/UL60950-1 Latest Edition
◆
Power Factor Corrected to EN61000-3-2 class D
◆
Peak Power 700W within 500uS Duty Duration
◆
High Quality & Reliable Component Usage
◆
Output Voltages for single output from 3 ~ 60Vdc
◆
Full Range AC Input
U type: 8(L) x 5(W) x 1.6(H) inches
PRODUCT SPECIFICATIONS:
Input Voltage:
90 ~ 264Vac full range, 47 ~ 63Hz.
Input Current:
6A at 90Vac full load.
Inrush Current:
70A peak maximum.(Measuring at 230VAC and full load
cold start.)
Power Factor Correction:
Meet EN61000-3-2 class D
Transient Response
Output voltage returns to within 1% in less than
2.5mS for a 50% load change and the peak transient does not excess 5%.
Overshoot:
Turn-on and turn-off overshoot should not exceed 5% over
nominal voltage.
Efficiency:
80% minimum (Measuring at 115V and full load).
Turn On Delay:
2 second maximum at 115 VAC.
Hold Up Time:
16m sec. minimum at 115VAC and 75% of rated maximum
load.
Adjustability:
Output user adjustable +/-5% minimum.
Remote On-Off:
Designated as RSW on the CN3, Requires a low signal to
inhibit output.
Remote Sense:
Designated as RS+ and RS- on the CN3, max. 0.5V
compensation for cable losses with respect to the main output voltage under
12V units.
Power Supply On:
When the Bi-color LED emit green light that indicates
the supply is operating. When any protection is occurred or RSW is applied
a low signal, the Bi-color LED will emit orange light.
Power Good:
Designated as PG on CN3. This signal will go high 100-500
Msec after the output reaches the regulation limit. It goes low at least 1
Msec before loss of regulation and has ability to sink 100mA.
Input Fusing Protection:
One T6.3A/250V fuse inserted in primary.
Input Voltage Protection:
Power shut down under 80 +/-10Vac, and
recovered over 90Vac.
Over-Power Protection:
Total power limits at 110-140% of the rated output
current and recovers automatically.
Short Circuit Protection:
Short circuit can be continuous without damage
and recovers automatically
Over Voltage Protection:
Output is protected against over voltage. Unit
latching down will occur when output exceed 130% max., and recycle AC
input to reset
Over-Temperature Protection:
Power supply protected in the
event of excessive operating ambient 110±5 degree C, and
automatic recovery.
Operating Temperature:
0℃ to 50℃ ambient.
Switching Frequency:
60kHz PFC, 27 kHz PWM
Vibration:
Frequency 5 to 50 Hz, acceleration
±7.35
m/s*s on X,Y
and Z Axis.
Storage Temperature:
-20℃ to 85℃.
Operating Humidity:
5% to 90% RH, Non-condensing.
Storage Humidity:
5% to 95% RH, Non-condensing.
EMI :
Meet FCC Part 15 Subject J class B, CISPR 22 class B, CE
Marked.
Safety Regulation:
Approved UL60950-1, CSA C22.2 No. 950-95,
EN60950 and CB certificate available.
Leakage Current: <500uA at 240Vac
HI-POT Test:
The power supply shall withstand for 3 Sec without
breakdown the application of a 1500 VAC supply voltage applied
between both input line and chassis (10mA ac cut off current).
Isolating transformers shall withstand 3000VAC applied between
primary and secondary windings and primary to core 1500VAC.
Grounding Test:
Apply 25 A current from the ground pin of the
three prong plug to the far most earthed connection point. The
maximum allowable resistance measured during the test is 0.1ohm.
Warranty:
2 years.
MTBF:
100000 Hrs (according to MIL-HBK-217F) at 30
℃
.
Open frame unit:
U Type: 8(L) x 5(W) x 1.6(H) inches
Burn in:
45 +/- 5 degree C for 1 hour @230Vac with full load.
Weight:
Maximum weight is 1000g.
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.
ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw
Tel:+886-2-29180118
Fax:+886-2-29181465
We Supply the Power Customers Need
ISO9001
OUTPUT VOLTAGE / CURRENT RATING CHART:
Measured at output power connector.
Model
Output Range
Preset
Voltage
Max. Output Current/Power
Regulation
Type U Convection
60A
40A
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
Ripple &
Noise
PRL1201-05
PRL1201-10
PRL1201-12
PRL1201-15
PRL1201-18
PRL1201-24
PRL1201-28
PRL1201-36
PRL1201-48
PRL1201-54
3– 5V
6– 10V
11– 13V
13.5– 16V
17 – 21V
22 – 25V
26 – 30V
31 – 40V
41 – 50V
51– 60V
5V
10 V
12 V
15 V
18V
24V
28V
36V
48V
54V
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
400W
400W
400W
400W
400W
400W
400W
400W
Note:
•PRL1201
series are designated as PRL1201-y where y can be 05, 10, 12, 15, 18, 24, 28, 36, 48 or 54.
•Providing
peak power to 700W within 500uS for all models, longer duty duration need contact manufacturer.
•All
output range are covered in agencies certification and the preset voltage will be set as standard models if any request
is not preset output then should contact us in advance.
•Maximum
400W continuous output with air convection for U type models.
•1%
minimum load is required to maintain the ripple and regulation.
•Output
is fully isolated
•Ripple
and noise is measured from 10KHZ to 20MHz bandwidth at output terminals with parallel 0.1µF ceramic and 22µF
electrolytic capacitors.
OUTLINE DRAWING:
Input Connector (CN1):
Mating Molex Part No. 09-50-3071 or equivalent (7 pin,5 used)
Howder Terminal block Part No. HD-121-3P
Output Connector (CN2):
Howder Terminal block Part No. HD-121-6P
Mating Molex Part No. 09-50-3141 (14 pin)
Output Pin Assignment:
(See table in right).
Mounting Inserts:
6-32, M4 4Places individually with maximum penetration 0.15” on bottom
side and 0.25” on both side
Logic signal connector (CN3):
Mating JST XHP-3 or equivalent (CHYAO SHIUNN JS-1001-05)
Mating Pins: JST SXH-002T-P0.6 FOR AWG 30 TO 26
PIN1: RS+ PIN2: RS- PIN3: RSW PIN4: RTN PIN5: P.G
Howder
Pins 1 ~ 3: VO+
Pins 4 ~ 6: VO-
Molex
Pins 1 ~ 7: VO+
Pins 8~ 14: VO-
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.