PRL1201 SERIES 180W to 400W AC TO DC ACTIVE PFC SWITCHING
POWER SUPPLY SPECIFICATION
FEATURES:
400W convection cooling with 1U height
Design meets IEC/EN/UL60950-1 Latest Edition
Power Factor Corrected to EN61000-3-2 class D
Peak Power 700W within 500uS Duty Duration
High Quality & Reliable Component Usage
Output Voltages for single output from 3 ~ 60Vdc
Full Range AC Input
U type: 8(L) x 5(W) x 1.6(H) inches
PRODUCT SPECIFICATIONS:
Input Voltage:
90 ~ 264Vac full range, 47 ~ 63Hz.
Input Current:
6A at 90Vac full load.
Inrush Current:
70A peak maximum.(Measuring at 230VAC and full load
cold start.)
Power Factor Correction:
Meet EN61000-3-2 class D
Transient Response
Output voltage returns to within 1% in less than
2.5mS for a 50% load change and the peak transient does not excess 5%.
Overshoot:
Turn-on and turn-off overshoot should not exceed 5% over
nominal voltage.
Efficiency:
80% minimum (Measuring at 115V and full load).
Turn On Delay:
2 second maximum at 115 VAC.
Hold Up Time:
16m sec. minimum at 115VAC and 75% of rated maximum
load.
Adjustability:
Output user adjustable +/-5% minimum.
Remote On-Off:
Designated as RSW on the CN3, Requires a low signal to
inhibit output.
Remote Sense:
Designated as RS+ and RS- on the CN3, max. 0.5V
compensation for cable losses with respect to the main output voltage under
12V units.
Power Supply On:
When the Bi-color LED emit green light that indicates
the supply is operating. When any protection is occurred or RSW is applied
a low signal, the Bi-color LED will emit orange light.
Power Good:
Designated as PG on CN3. This signal will go high 100-500
Msec after the output reaches the regulation limit. It goes low at least 1
Msec before loss of regulation and has ability to sink 100mA.
Input Fusing Protection:
One T6.3A/250V fuse inserted in primary.
Input Voltage Protection:
Power shut down under 80 +/-10Vac, and
recovered over 90Vac.
Over-Power Protection:
Total power limits at 110-140% of the rated output
current and recovers automatically.
Short Circuit Protection:
Short circuit can be continuous without damage
and recovers automatically
Over Voltage Protection:
Output is protected against over voltage. Unit
latching down will occur when output exceed 130% max., and recycle AC
input to reset
Over-Temperature Protection:
Power supply protected in the
event of excessive operating ambient 110±5 degree C, and
automatic recovery.
Operating Temperature:
0℃ to 50℃ ambient.
Switching Frequency:
60kHz PFC, 27 kHz PWM
Vibration:
Frequency 5 to 50 Hz, acceleration
±7.35
m/s*s on X,Y
and Z Axis.
Storage Temperature:
-20℃ to 85℃.
Operating Humidity:
5% to 90% RH, Non-condensing.
Storage Humidity:
5% to 95% RH, Non-condensing.
EMI :
Meet FCC Part 15 Subject J class B, CISPR 22 class B, CE
Marked.
Safety Regulation:
Approved UL60950-1, CSA C22.2 No. 950-95,
EN60950 and CB certificate available.
Leakage Current: <500uA at 240Vac
HI-POT Test:
The power supply shall withstand for 3 Sec without
breakdown the application of a 1500 VAC supply voltage applied
between both input line and chassis (10mA ac cut off current).
Isolating transformers shall withstand 3000VAC applied between
primary and secondary windings and primary to core 1500VAC.
Grounding Test:
Apply 25 A current from the ground pin of the
three prong plug to the far most earthed connection point. The
maximum allowable resistance measured during the test is 0.1ohm.
Warranty:
2 years.
MTBF:
100000 Hrs (according to MIL-HBK-217F) at 30
.
Open frame unit:
U Type: 8(L) x 5(W) x 1.6(H) inches
Burn in:
45 +/- 5 degree C for 1 hour @230Vac with full load.
Weight:
Maximum weight is 1000g.
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.
Agitek Engineers - How to Measure Cable Impedance and Loss Using a Vector Network Analyzer
Step 1: Calibration.In addition to the cable to be tested, another auxiliary cable is also required. The ZVB8 vector network analyzer (hereinafter referred to as VNA) we use has two ports: Port1 and P...
agitek安泰维修 Test/Measurement
How to Layout a Circuit Board for an Op Amp
[align=left][color=rgb(51, 51, 51)]During the circuit design process, applications engineers often overlook the layout of the printed circuit board (PCB). The problem often encountered is that the cir...
okhxyyo PCB Design
【RVB2601 debugging record 2】+ uGUI porting
Debug Log 2 Using Hardware SPI The speed of the simulated SPI last time was a bit impressive, this time I use hardware SPI csi_gpio_pin_t pin_clk; csi_gpio_pin_t pin_mosi; csi_gpio_pin_t pin_cs; csi_g...
qwert1213131 XuanTie RISC-V Activity Zone
Visitor registration is in progress丨2021 Munich South China Electronics Show (Shenzhen International Convention and Exhibition Center) invites you to participate!
From October 28 to 30, 2021 , at the Shenzhen World ExhibitionConvention Center (Bao'an New Hall) , the member exhibition of the 2021 South China International Intelligent Manufacturing, Advanced Elec...
eric_wang Integrated technical exchanges
Motion Detector Using MSP430 Launchpad and PIR Sensor
Motion detection is an important part of security system and PIR sensor is one of the most commonly used sensors to trigger alarm when motion is detected. This sensor can easily detect the motion of p...
灞波儿奔 Microcontroller MCU
2022 Digi-Key Innovation Design Competition Unboxing
A while ago, I happened to see the registration for the Digi-Key Innovation Design Competition, and I took part in it with the mentality of giving it a try. Fortunately, I was selected in the first ba...
1394526302 DigiKey Technology Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号