50 Amp Latching PCB Relay
FEATURES
PC10L-50
Energy Saving Latching Operation
50 Amp Switching Capacity
5,000 Watt Lamp Load @ 240 VAC
5 HP @ 277 VAC Motor Load
Max Inrush Current 200 Amp for 2 ms
Single or Dual Coil
Manual Switch On Top
39.0 x 25.0 x 15.0 mm Package Dimensions
5.0 mm Shorter than Completion's version
RoHS Compliant
E93379
Load Type
Resistive 6,000 Cycles
Incandescent Lamp 3,000 Cycles
Incandescent Lamp 3,000 Cycles
Electronic Ballast 6,000 Cycles
Motor Load 3,000
Voltage
277 VAC
240 VAC
277 VAC
280 VAC
277 VAC
277 VAC
1 Form A
(SPST-NO)
50 A
5,000 W
16 A
16 A
5 HP
50 A
CONTACT DATA
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
Minimum Operating Contact Current
Material
Initial Contact Resistance
Service Life
Mechanical
Electrical
8 mm
10 N
10 - 55 Hz Double Amplitude 1.5 mm
- 40 to 70
°C
- 40 to 125
°C
235 ºC ± 2°C 3 sec ± 0.5 sec
85% at 40°C
25 grams
12,500 VA
440 VAC
50 A
10 mA @ 6 VDC & 25ºC
100 mA @ 6 VDC
Over Operating Temp.
AgSnO
2
≤ 20mΩ Initial
5 X 10
6
Operations
1 X 10
5
Operations
UL APPROVALS
General Purpose
CHARACTERISTICS
Operate Time
Release Time
≤ 15 ms
≤ 15 ms
50 Hz 4,000 V 1 min.
Between Coil and Contact
50 Hz 1,500 V 1 min.
Between Contacts
Creep
Terminal Strength
Vibration Resistance
Operating Temperature
Storage Temperature
Solderability
Relative Humidity
Weight
Insulation Resistance
1,000 MΩ min at 500 VDC
Dielectric Strength
Shock Resistance
98 m/s
2
11 ms Functional
980 m/s
2
11 ms Survival
Power
Consumption
Single Coil: 1.5 W: Double Coil: 2 X 3.0 W
ORDERING INFORMATION
Example:
Model:
PC10L-50
Contact Form:
1A
Coil Voltage:
3, 9, 12, 24, 48
Enclosure:
Nil:
Dust Cover
Coil:
Nil:
Single Coil 1.5 W,
D:
Double Coil 2 X 3.0 W
Polarity:
Nil:
Standard,
R:
Reverse Polarity
RoHS Compliant:
-X
Box Quantity: 1000 ; Inner Box 500
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272 (888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PC10L–50 Rev B 2/08/2016
1 of 2
PC10L-50
-1A
-3
- Nil
-D
-R
-X
www.PickerComponents.com
e-mail: sales@pickercomponents.com
Specifications and Availability subject to change without notice.
PC10L-50
COIL DATA
Coil Voltage
Rated
Maximum
6
7
9
10.6
12
14.4
24
28.8
48
56
Pulse Magnitude ≥ 50 ms;
Coil Power
Resistance (Ohms ± 10%)
Single Coil 1.5 Watts Dual Coil 2 x 3.0 Watts
24
12 + 12
54
27 + 27
96
48 + 48
384
192 + 192
1,536
768 + 768
Must Operate
Voltage Max
(VDC)
4.8
7.2
9.6
19.2
38.4
PC10L-50
NOTES:
With the Dual Coil Version, the Latch and Reset Coils should not be pulsed at the same time for it is possible to set the relay into a magnetically neutral position.
Coils should not be pulsed with less than the rated coil voltage and the pulse width should be a minimum of three times the specified operate time. If not, it is
possible for the relay to settle in a magnetically neutral position.
DIMENSIONS (inches/mm)
Dimensions are in mm, Inches are listed for reference only.
Bottom View of Relay
Side View of Relay
Top View of Relay
1A
1A Reverse
1A Dual
1A Dual Re-
Wire Diagrams
3220 Commander Drive, Suite 102 Carrollton, TX 75006
Sales: (972) 713-6272 (888) 997-3933
Fax: (972)735-0964
Dimensions are listed for reference purposes only.
PC10L–50 Rev B 2/08/2016
2 of 2