SF002B162R0/162R0FA

Description
Array/Network Resistor, Isolated, 0.5W, 162ohm, 1% +/-Tol, -5,5ppm/Cel, 5511
CategoryPassive components    The resistor   
File Size469KB,2 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance  
Download Datasheet Parametric View All

SF002B162R0/162R0FA Overview

Array/Network Resistor, Isolated, 0.5W, 162ohm, 1% +/-Tol, -5,5ppm/Cel, 5511

SF002B162R0/162R0FA Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
structureConformal Coated
Lead length5 mm
Manufacturer's serial numberSF
Network TypeIsolated
Number of terminals4
Maximum operating temperature125 °C
Minimum operating temperature-25 °C
Package height10 mm
Package length14 mm
Package formPCB Mount
Package width2.7 mm
Rated power dissipation(P)0.5 W
resistance162 Ω
Resistor typeARRAY/NETWORK RESISTOR
seriesSF
size code5511
Temperature Coefficient-5,5 ppm/°C
Tolerance1%
Thyristor control relay problem analysis
The control circuit below is shown in the figure. The live wire first passes through the thyristor circuit zero-crossing trigger and then reaches the relay circuit.Every 15 waveforms of the heating po...
灞波儿奔 Power technology
A flyback adapter reference design with a maximum output of 9V 5A
The reference design scheme introduced is a flyback adapter reference design with a maximum output of 9V 5A. The scheme adopts the high-efficiency active clamp flyback controller UCC28780 and the seco...
qwqwqw2088 Analogue and Mixed Signal
The 8th Committee of the Communications Branch of the China Institute of Electronics was recently established
The 8th Committee of the Communications Branch of the China Institute of Electronics was recently established2006-06-02  Recently, the 8th Committee of the Communication Branch of the China Electronic...
fighting Analog electronics
Download Gift|ADI Flow Cytometer Solution
Flow cytometer is a medical and life science instrument that uses light or impedance-based technology for cell sorting, biomarker detection, protein engineering, and diagnosis of health diseases such ...
EEWORLD社区 Medical Electronics
【GD32F350】The simulation fails after a burst of smoke
[i=s] This post was last edited by Changjianze1 on 2018-8-28 18:45 [/i] I was so naughty that I had to measure the 5V GND. I accidentally touched the test lead and it was short-circuited. It was smoki...
常见泽1 GD32 MCU
EEWORLD University Hall----Application of TI DLP? Technology in 3D Machine Vision and Automated Optical Inspection
TI DLP? Technology in 3D Machine Vision and Automated Optical Inspection : https://training.eeworld.com.cn/course/4839...
hi5 Talking

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号