EEWORLDEEWORLDEEWORLD

Part Number

Search

ABKUK030U9

Description
ABKUK030U9
CategoryPassive components    The resistor   
File Size475KB,15 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

ABKUK030U9 Overview

ABKUK030U9

ABKUK030U9 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codenot_compliant
ECCN codeEAR99
3
CIRCUIT BREAKERS FOR EQUIPMENT
TA45: 2 pole, push button actuated
• Thermal release
• Positively trip-free
The 2 pole, push button actuated version of the TA45 line of thermal
CBE’s can be used for various purposes. Basically it is a CBE for
automatic interruption of overloads with facilities for regular manual
ON/OFF switching operations under normal load conditions. It is
capable of interrupting moderate short circuit currents without the aid
of back-up protection.
A special version is available as a «CBE-switch», in which the means
for automatic overcurrent interruption (the bimetal relases), are
omitted.
Another available version of this line utilizes an under-voltage release
to protect persons against injuries caused by unexpected events like
the automatic restarting of motors after a power failure. This release
can be combined with the thermal release required for overcurrent
protection. Protection against injuries is also provided by another CBE
of this line, which prevents the starting of a machine should a
protective cover be removed from dangerous parts of the machine.
Available options:
• CBE for overcurrent protection
1 or 2 protected poles (thermal)
• CBE with undervoltage release:
The CBE will open automatically when the voltage drops below the
trip level. Only when the supply voltage has reached the reset
level, the CBE can be reclosed manually.
• CBE switch with mechanical lock-out latch:
A spring loaded pin will trip the CBE if a protective cover of the
equipment is removed. The CBE can not be switched ON until the
protective cover is refitted.
• CBE with remote trip release:
The remote trip release permits the CBE to be tripped by a external
contact (sensor) energizing the trip coil.
• CBE with auxiliary contact:
All types of the line can be outfitted with an auxiliary contact
(changeover contact).
TA45 is positively trip-free. The rated current range is 0,1 to 20 A at
AC 230 V / DC 60 V. The CBE comes with snap-in mounting or
flange mounting. A locking device suitable for padlocks prevents
unauthorized switching ON of the CBE. The TA45 is approved in all
major industrial countries and complies with the CBE-standard
EN60934.
In conjunction with its accessories the TA45 product line of Schurter
paves the way for new unconventional applications.
Applications
Motors
Power supplies
Processing machines
etc.
238
Schurter, Inc. • Phone 707-778-6311 •
• Fax 707-778-6401 •
E-mail info@schurterinc.com •
Website http://www.schurterinc.com
Phone 707-778-6311
Fax 707-778-6401 •
E-mail info@schurterinc.com Website http://www.schurterinc.com
Firmware Programming
As a beginner, I want to learn firmware programming. What books should I read and how should I start learning? I would like to ask the experts to recommend some books or video tutorials....
自由达人 Programming Basics
EEWORLD University - Introduction to Computer Science and Programming
Introduction to Computer Science and Programming : https://training.eeworld.com.cn/course/4681This course is intended for students with little or no programming experience. It aims to give students an...
老白菜 DIY/Open Source Hardware
Cumulative error analysis and clock frequency optimization for UART communication in MSP430FR2311
[align=left][font="][size=3][color=#000000][backcolor=white]In UART communication design, engineers will first select the appropriate baud rate according to system needs, and then select the appropria...
fish001 Microcontroller MCU
Learn 3D visualization from scratch: Exploded diagram
What is the first thing that comes to your mind when you think of an exploded image? Is it this?No, no, no, now the exploded view generally refers to the three-dimensional assembly drawing. With the e...
森友js Sensor
1000m WIFI amplifier ~ Anyone interested?
A few days ago, I posted a thread hoping that everyone would brainstorm and come up with something. A netizen recommended this tool for surfing the Internet from a distance of a thousand meters. It so...
okhxyyo RF/Wirelessly
FilterSolutions User's Guide The simulated filter that has been practiced is pretty good
FilterSolutions User's Guide This is the original English version to help you read it....
btty038 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号