Part Number

Search

K3JD2EAA12

Description
Rocker Switch, DPDT, (on)-off-(on), 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size965KB,3 Pages
ManufacturerOTTO
Websitehttp://www.ottoexcellence.com
Environmental Compliance
Download Datasheet Parametric View All

K3JD2EAA12 Overview

Rocker Switch, DPDT, (on)-off-(on), 20A, 12VDC, Quick Connect Terminal, Rocker Actuator, Panel Mount

K3JD2EAA12 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator colorRED
Actuator length0.42 inch
Actuator materialTHERMOPLASTIC
Actuator typeROCKER
Body colorBLACK
body height35.306 mm
center contact materialBRASS
Contact (AC) maximum rated power R load0.5HP@110VAC
Contact (AC) maximum rated load I15A@125VAC
Contact (AC) maximum rated R load16A@125VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)20 A
Contact (DC) maximum rated R load20A@12VDC
Contact function(ON)-OFF-(ON)
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)12 V
Dielectric withstand voltage1500VAC V
Electrical life25000 Cycle(s)
End contact materialBRASS
insulator materialTHERMOPLASTIC
Manufacturer's serial numberK3
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
surface mountNO
switch functionDPDT
Switch typeROCKER SWITCH
Terminal length0.39 inch
Terminal materialBRASS
Termination typeQUICK CONNECT
SEALED, ILLUMINATED ROCKER SWITCHES
ATTRACTIVE & RUGGED FOR WET & DUSTY ENVIRONMENTS
SEALED
ROCKERS
K3
The OTTO K3 rocker switch is a quality, precision switch designed
to comply with standards established for appliance, marine (ignition
protection) and off-road vehicles along with other demanding
applications where rugged rocker switches are required.
K3 sealed rocker switches snap into industry-standard panel
cutouts. Choose illuminated and printed legends, thru-panel
drain option and switching compatibility from low level to
20 amps.
The K3 offers a choice of LED, incandescent and neon
illumination. Legends can be stamped onto a non-illuminated
button, stamped onto an illuminated lens or laser etched into
the lens and backlit.
Available in standard and low level contact ratings, the K3
rockers will fit a wide range of applications. Expect a minimum
of 25,000 cycles at a full rated load of 20 amps resistive or 15
amps inductive. 100,000 cycles mechanical. A full complement
of switch operation is available including momentary and
maintained action in 2 or 3-position switches in SPST, SPDT,
SPTT, DPST and DPDT circuit arrangements.
OTTO can provide custom colors upon request. Value-added
assemblies with wire leads are also available. Please consult the
factory for assistance.
Standard Characteristics/Ratings:
ELECTRICAL RATINGS:
Load
Resistive
Inductive
Lamp
Motor
DWV
Low Level
Electrical Life:
25,000 cycles
Sea Level
@ 12/28VDC
20A
15A
5A
0.5HP @ 110VAC
1050Vrms except across light terminals
10mA @ 30mV
Sea Level
@ 125VAC, 60Hz
16A
15A
5A
ROCKER SWITCHES
Features:
• Sealed watertight per IP68S
• Snap-in panel mounting into industry standard
panel cutout
• Optional panel seal gasket
• Thru-panel drain option
• LED, neon & incandescent lighting
• 0.250” Quick Connect terminals
• Optional one-piece connector
• Optional terminal barriers
• Low level up to 20 amp switch
• Configurable Single Pole Triple Throw (SPTT)
with external jumpers
• RoHS/WEEE/Reach compliant
LIGHTING:
Light Source
Incandescent
Neon
LED
Mechanical Life:
Seal:
Rating
(VDC) 6V, 12V, 24V
(VAC) 125V, 250V
(VDC) 2V, 6V, 12V, 24V
100,000 cycles
IP68S
Operating Temp Range:
-40°C to +85°C
MATERIALS:
Case:
Button:
Terminals/Contact:
Terminal Hardware:
Thermoplastic, black
Thermoplastic
Brass, silver alloy with silver plate, gold flash for low level
K3 series recommended Quick Connect terminals:
AMP 60253-2 for 12-16 AWG
AMP 42100-2 for 14-18 AWG
None provided
Mounting Hardware:
Specifications Subject To Change Without Notice
www.ottoexcellence.com
153
Is this the worst impedance processing you have ever encountered?
Author: Mr. Huang Gang of Yibo Technology Expressway This case is a high-speed custom fixture for a PCIE connector that we designed with a customer. We were responsible for the design and simulation, ...
yvonneGan PCB Design
PCB panelization
The so-called jigsaw puzzle, as the name suggests, is to put several boards together. There are two main points here: 1. Because some PCBs are too small, it is inconvenient to produce, it takes a lot ...
qwqwqw2088 PCB Design
RPG game ported using RP2040 and MicroPython
RPG game ported using RP2040 and MicroPython...
dcexpert MicroPython Open Source section
For large project files containing nios, timing constraints, and layout and routing, modify the internal module names and some variable names.
I modified the internal module names and some variable names of a large project file containing nios, timing constraints, and layout and routing. After compiling and synthesizing, a lot of problems oc...
FPGA菜鸡 EE_FPGA Learning Park
What is output impedance? What is impedance matching?
[b]1. Output impedance[/b][align=left][color=rgb(34, 34, 34)][font="]Before understanding the issue of "impedance matching", let's first learn what "output impedance" is?[/font][/color][/align][align=...
tiankai001 Analog electronics
High-frequency transformer sandwich winding method: primary wrapped in secondary? Or secondary wrapped in primary?
[i=s]This post was last edited by qwqwqw2088 on 2019-5-14 07:58[/i] [size=4]Sandwich winding[/size] [size=4] [/size] [align=center][size=4][/size][/align][size=4] The sandwich winding method has a lon...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号