DC/DC Converter; Product Weight (grams): 65; Input voltage min (V): 18; Input voltage max (V): 36; Output voltage min: 24; Output voltage max: 24; Output voltage dual assymetric (y/n): Single; Output Power (W): 40; Max Output current (A): 1.5; Efficiency (%): 86; Package type: 2x2; Mounting: PCB; W (in): 2; L (in): 2; H (in): 0.4; W (mm): 50.81; L (mm): 50.81; H (mm): 10.2; Min Operating temperature: -40; Max operating temperature (°C): 75; Isolation (VDC): 3000; Case material: Copper; Application 4 (building automation/IoT): 1; Application 5 (Industrial): 1; MTBF (h): 1500000; Derating : 45; Voltage Accuracy (%): ±2; Line Regulation (% of Vin): ±0.5; Load Regulation %: ±0.5; Ripple & Noise (mV p-p): 240; Switching Frequency typ (KHz): 250; Short circuit protection: Continuous; On/Off Control: 1; Voltage adjustment: 1
DC/DC Converter; Product Weight (grams): 65; Input voltage min (V): 18; Input voltage max (V): 36; Output voltage min: 24; Output voltage max: 24; Output voltage dual assymetric (y/n): Single; Output Power (W): 40; Max Output current (A): 1.5; Efficiency (%): 86; Package type: 2x2; Mounting: PCB; W (in): 2; L (in): 2; H (in): 0.4; W (mm): 50.81; L (mm): 50.81; H (mm): 10.2; Min Operating temperature: -40; Max operating temperature (°C): 75; Isolation (VDC): 3000; Case material: Copper; Application 4 (building automation/IoT): 1; Application 5 (Industrial): 1; MTBF (h): 1500000; Derating : 45; Voltage Accuracy (%): ±2; Line Regulation (% of Vin): ±0.5; Load Regulation %: ±0.5; Ripple & Noise (mV p-p): 240; Switching Frequency typ (KHz): 250; Short circuit protection: Continuous; On/Off Control: 1; Voltage adjustment: 1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Voltage
(V)
Output Voltage
(V)
Output Current
max
(A)
Isolation
(VDC)
Input Specifications
Voltage range
Filter
Absolute Maximum Rating
On/Off control
Parameters
Nominal
12
24
48
12
24
48
Typical
25
50
100
ON –TTL High or Open ; OFF – TTL Low or short
9-18
18-36
36-75
π(Pi) Network
Maximum
Units
VDC
VDC
Isolation Specifications
Tested I/O voltage
Resistance
Parameters
Conditions
3 sec
500VDC
1500 or 3000
>1000
Typical
Maximum
VDC
MOhm
Units
Output Specifications
Voltage accuracy
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Voltage adjustment range
Minimum Load Current
Parameters
±2
Zener diode clamp
>110 FL
Continuous
Auto-Restart
±0.5
Iout=25% to 100%
±0.5
Iout=25% to 100%
±2
±0.05
20MHz Bandwidth (5 & 3.3Vout)
80
All other output models
1
±10
25
Conditions
Typical
Maximum
Units
%
%
% of Vin
%
%
%/
o
C
mV p-p
% p-p Vout
%
% of Max
General Specifications
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
www.aimtec.com
F 051e R12
Parameters
Conditions
100% load
Typical
See chart below
250
-40 to +75
-55 to +115
100
45
Free air convection
Maximum
Units
KHz
o
C
o
C
o
C
o
C
95
% RH
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Tel: +1 514 620 2722
2 of 5
40Watt | DC-DC Converter
General Specifications (continued)
Case material
Weight
Dimensions
(L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Series AM40U-IZ
Units
g
C
uS
o
Parameters
Conditions
Nickel
– coated Copper with nonconductive base
65
2.00 x 2.00 x 0.40 inches
50.81 x 50.81 10.20 mm
>1
500 000 hrs ( MIL-HDBK-217 F at +25
o
C)
280
Typical
Maximum
50% load step change
Pin Out Specifications
Pin
1
2
3
4
5
6
7
Single
+V Input
-V Input
On/Off Control
No pin
+V Output
-V Output
Trim
1000 & 3000VDC
Dual
+V Input
-V Input
On/Off Control
+V Output
Common
-V Output
Trim
Dimensions
50.80
(2.00)
22.86
(0.90)
50.80
(2.00)
5.08
(0.20)
10.16
(0.40)
2
3
45.70
(1.80)
7
Printed Face
Side View
5.60
(0.22)
1.00
(0.04)
Dimensions mm (inch)
Case Tolerance: ±0.25mm (±0.02inch)
Pin Length Tolerence: ±0.05mm (±0.002inch)
Trimming
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
3 of 5
10.16
(0.40)
6
10.16
(0.40)
1
Bottom View
5
10.16
(0.40)
4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
40Watt | DC-DC Converter
Derating
Series AM40U-IZ
Free Air Convection
45 º C
100
Output Power (%)
80
60
40
20
0
- 40
- 20
0
20
40
60
75
Safe Operating Area
35
80
100
Ambient Temperature
º C
Control ON/OFF pin connection example
Single Output
Dual Output
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
40Watt | DC-DC Converter
Digital Control Circuit:
Control
Voltage
0.5mA
0V
Ra =
Vpeak
– 0.6
0.5mA
NPN
Series AM40U-IZ
Vpeak
On / Off Control
DC/DC
Converter
-V input
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4
. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this
datasheet
.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
[align=left][font=宋体]As enterprises modernize their compute and network architectures, cloud-native architectures are the primary goal. [/font]Cloud computing has become the dominant paradigm for ente...
With the advent of the Internet of Things, the automation and intelligence of urban transportation require a comprehensive upgrade. Traditional street lamps are gradually being replaced, and the stabi...
while(1){BTLE_StackTick();printf("ticks=%d",HAL_VTimerGetCurrentTime_sysT32());
}
When testing, everything is normal, but when I delete BTLE_StackTick();, I find that ticks will restart from 0 when it...
ITS (Intelligent Transport System) is a system that significantly improves road traffic safety and transportation efficiency by IT-based (equipment information system) vehicles and roads.Some cars hav...
[align=left][color=rgb(34, 34, 34)][font="]In the microcontroller system, pull-up resistors have gradually become the most stable and reliable main component. [/font][/color][/align][align=left][color...
SAIC Motor announced on the evening of August 30 that it plans to jointly establish SAIC Qingtao New Energy Technology Co., Ltd. (subject to the name approved by the Market Supervision Administration...[Details]
1 Introduction The application of single-chip microcomputer in the field of industrial control is different from that in the civil and commercial fields. The environment of industrial control is rela...[Details]
Efficiently promote the expansion from traditional models to digitalization and diversification
Germany's MR company becomes an excellent partner in the power industry to promote globali...[Details]
In recent years, as products such as automotive components and wearable devices have become more efficient, the high voltage resistance and insulation properties of components must also be improved. ...[Details]
U.S. semiconductor company Xilinx said on Wednesday it had secured a deal to supply 5G network equipment chips to Samsung, Reuters reported. Xilinx makes programmable chips for telecom equipment an...[Details]
1. Application background As a basic universal time domain instrument, oscilloscopes are widely used in measurements in electronics-related fields. Generally, oscilloscopes are equipped with up to 4 ...[Details]
1. Encoder principle If the two signals are 90 degrees out of phase, they are called orthogonal. Since the two signals are 90 degrees out of phase, the direction can be determined based on which of t...[Details]
The clamp ammeter is a portable meter made using the principle of current transformer. It is widely used because of its convenience. When using a clamp ammeter, the line current can be measured with...[Details]
According to foreign media reports, OneD Battery Sciences, a leader in electric vehicle battery technology, announced the launch of a breakthrough technology that can power the next generation of ele...[Details]
Many years ago, I was proud of the tens of thousands of lines of assembly code I had written. However, as someone who has been engaged in software development for many years, I still don’t understa...[Details]
introduction
The current water shortage is a global problem, and water shortage will become an important factor restricting the national economy and social development. At present, my country'...[Details]
What are the applications of domestic inverters in energy saving? This is the relevant question we want to talk about in this issue. The answer to this question is in the following explanation: ...[Details]
In recent years, greenhouse cultivation has brought great convenience to improve people's living standards and has been rapidly promoted and applied. Environmental factors such as temperature, humidit...[Details]
There are two basic property nodes for position information of front panel objects: BOUNDS AND POSITION. Let's look at BOUNDS first.
Bounds is composed of two elements, height and width. Its unit is ...[Details]
0 Introduction
At present, the communication, monitoring and data acquisition system of the power system adopts a distributed communication structure. With the application of new equipment and ne...[Details]