Series AM40U-AZ
FEATURES:
•
•
•
•
Wide Input 2:1 Range
Full Internal SMD Technology
1600 VDC Isolation
Efficiency up to 89%
•
•
•
•
Adjustable Output Voltage
Remote ON/OFF Function
Over Load, Voltage & Short Circuit Protection
Operating temperature -40
o
C to + 85
o
C
40 Watt | DC-DC Converter
Models
Single output
Model
AM40U-1203SAZ
AM40U-1205SAZ
AM40U-1212SAZ
AM40U-1215SAZ
AM40U-2403SAZ
AM40U-2405SAZ
AM40U-2412SAZ
AM40U-2415SAZ
AM40U-4803SAZ
AM40U-4805SAZ
AM40U-4812SAZ
AM40U-4815SAZ
Input Voltage
(V)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
Output Voltage
(V)
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
Output Current
max
(A)
8
8
3.3
2.6
8
8
3.3
2.6
8
8
3.3
2.6
Isolation
(VDC)
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
Efficiency
(%)
85
86
86
87
86
88
88
89
87
88
89
89
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Input reflected ripple current
Nominal
12
24
48
12
24
48
9-18
18-36
36-75
π(Pi) Network
25
Typical
Maximum
Units
VDC
ms
VDC
ms
mA p-p
20
36
50
100
100
Isolation Specifications
Tested I/O voltage
Resistance
Capacitance
Parameters
Conditions
3 sec
Typical
>1000
220
Rated
1600
VDC
MOhm
pF
Units
Output Specifications
Voltage accuracy
Over voltage protection
Over load protection
Short Circuit protection
Short circuit restart
Thermal shutdown
Line voltage regulation
www.aimtec.com
F 051e R12.D
Parameters
Conditions
Foldback
On Case
HL-LL
±2
Zener Diode Clamp
135~150
Continuous
Auto-Restart
110
±1
Typical
Maximum
Units
%
%
ºC
% of Vin
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40U-AZ
Output Specifications (continued)
Load voltage regulation (Single)
Temperature coefficient
Ripple & Noise
Voltage adjustment range
40 Watt | DC-DC Converter
Maximum
Units
Parameters
Iout=10% to 100%
20MHz Bandwidth
Conditions
Typical
±2
±0.02
75
±10
%
%/
o
C
mV p-p
%
General Specifications
Switching frequency
Parameters
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions
(L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
100% load
With derating above 55
o
C
(see graph below)
Above 55 C
o
Conditions
Typical
300
-40 to +85
-55 to +125
2
Free Air Convection
Maximum
Units
KHz
o
o
o
C
105
95
C
C
%/
o
C
% RH
g
C
uS
o
Nickel
– coated Copper
60
2.00 x 2.00 x 0.40 inches
50.81 x 50.81 10.14 mm
>1 500 000 hrs ( MIL-HDBK-217 F at +25
o
C)
1.5mm from case for 10 sec
260
500
25% load step
±4% of Vout
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1:2001 and EN55022:2006 + A1:2007, Class B
Pin Out Specifications
Pin
1
2
3
4
5
6
7
8
Single
+V Input
-V Input
On/Off Control
-Sense
+Sense
+V Output
-V Output
Trim
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM40U-AZ
Dimensions
50.80
(2.00)
40 Watt | DC-DC Converter
5.08
(0.20)
50.80
(2.00)
1
2
27.90
(1.10)
5
6
7
8
5.08
5.08
(0.20) 7.62 (0.20)
7.62
(0.30)
(0.30)
Bottom View
4
3
10.16
(0.40)
2.54
(0.10)
2.54
(0.1)
45.72
(1.80)
Printed Face
Dimensions mm(inch)
Case Tolerance ±0.50 (±0.02)
Pin Pitch Tolerance ±0.35 (±0.014)
5.08
(0.20)
Derating
Free Air Convection
55º C
100
10.16
(0.40)
Ø 1.00
(0.04)
Trimming
Output Power (%)
80
60
40
20
0
- 40
- 20
0
20
40
60
80
85
Safe Operating Area
100
Ambient Temperature
º C
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured.
3.
Mechanical drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release.
6.
This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.D
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
32.98
(1.30)