EEWORLDEEWORLDEEWORLD

Part Number

Search
 PDF

GRPM6L-100PCBSB4-40N-.190513

Description
D Type Connector, 100 Contact(s), Male, Solder Terminal, Locking
CategoryThe connector    The connector   
File Size193KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

GRPM6L-100PCBSB4-40N-.190513 Overview

D Type Connector, 100 Contact(s), Male, Solder Terminal, Locking

GRPM6L-100PCBSB4-40N-.190513 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codecompliant
ECCN codeEAR99
body width0.6 inch
subject depth0.64 inch
body length2.385 inch
Contact to complete cooperationAU ON NI
Contact completed and terminatedGold (Au) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialBERYLLIUM COPPER
contact modeSTAGGERED
Contact resistance8 mΩ
Contact styleRND PIN-SKT
Dielectric withstand voltage600VAC V
Insulation resistance5000000000 Ω
JESD-609 codee4
Manufacturer's serial numberGRPM
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
PCB row number6
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
PCB contact patternSTAGGERED
PCB contact row spacing1.905 mm
Rated current (signal)3 A
reliabilityCOMMERCIAL
Shell materialALUMINUM
Terminal length0.19 inch
Terminal pitch1.905 mm
Termination typeSOLDER
Total number of contacts100
Is there a dual Schottky diode similar to BAT54x that can pass a larger current (0.6A*2)?
RT! As shown in the picture Requirements: Single tube current0.5A, dual tube1A; Forward conduction voltage0.4V; Reverse breakdown voltage20V...
oyhprince Analog electronics
Discussion on the Link between Test Equipment and Design Tools
Discussion on the Link between Test Equipment and Design Tools...
feifei Test/Measurement
Is there any good software architecture for microcontroller embedded projects?
MCU, stm32 good overall software architecture...
pengyongnet 51mcu
Siemens Communications' fixed network, mobile network and operator service departments have been merged into Nokia. Where will the enterprise network go?
Siemens today officially announced that the fixed network, mobile network and operator service departments of the communications group will be merged into Nokia, thus confirming the rumors that the co...
1234 RF/Wirelessly
STM32 transplant fatFs write file failed
I would like to ask the experts: After transplanting FatFs, I can create files and write successfully. I observe in the mem_cpy function during single-step debugging that the address data is also writ...
hynh stm32/stm8
Questions about code execution in RAM
These days I'm trying to move the 28335 code from FLASH to RAM for execution. I'm indirectly verifying whether the move is successful by repeatedly performing a sinusoidal calculation. When running th...
asdmaill Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号