MIL–PRF (CWR Style) Established Reliability – T419 Series CWR19 Style MIL–PRF–55365/11
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
VDC
Rated
Cap
µF
3.3
4.7
6.8
10
15
22
22
33
33
47
68
100
150
220
330
3.3
4.7
6.8
10
15
15
15
22
22
33
47
68
68
100
150
220
330
2.2
3.3
4.7
4.7
6.8
6.8
6.8
10
10
10
10
15
15
22
33
47
47
µF
Case Code/
Case Size
KEMET/EIA
A/1005
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
D/1510
E/2010
E/2010
E/2010
F/2214
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
G/2711
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
C/2005
B/1505
C/2005
D/1510
B/1505
C/2005
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T419A335(1)004(2)(3)(4)
T419A475(1)004(2)(3)(4)
T419A685(1)004(2)(3)(4)
T419B106(1)004(2)(3)(4)
T419B156(1)004(2)(3)(4)
T419B226(1)004(2)(3)(4)
T419D226(1)004(2)(3)(4)
T419D336(1)004(2)(3)(4)
T419E336(1)004(2)(3)(4)
T419E476(1)004(2)(3)(4)
T419E686(1)004(2)(3)(4)
T419F107(1)004(2)(3)(4)
T419G157(1)004(2)(3)(4)
T419H227(1)004(2)(3)(4)
T419H337(1)004(2)(3)(4)
T419A335(1)006(2)(3)(4)
T419A475(1)006(2)(3)(4)
T419B685(1)006(2)(3)(4)
T419B106(1)006(2)(3)(4)
T419B156(1)006(2)(3)(4)
T419D156(1)006(2)(3)(4)
T419E156(1)006(2)(3)(4)
T419D226(1)006(2)(3)(4)
T419E226(1)006(2)(3)(4)
T419E336(1)006(2)(3)(4)
T419F476(1)006(2)(3)(4)
T419F686(1)006(2)(3)(4)
T419G686(1)006(2)(3)(4)
T419G107(1)006(2)(3)(4)
T419G157(1)006(2)(3)(4)
T419H227(1)006(2)(3)(4)
T419H337(1)006(2)(3)(4)
T419A225(1)010(2)(3)(4)
T419A335(1)010(2)(3)(4)
T419B475(1)010(2)(3)(4)
T419C475(1)010(2)(3)(4)
T419B685(1)010(2)(3)(4)
T419C685(1)010(2)(3)(4)
T419D685(1)010(2)(3)(4)
T419B106(1)010(2)(3)(4)
T419C106(1)010(2)(3)(4)
T419D106(1)010(2)(3)(4)
T419E106(1)010(2)(3)(4)
T419D156(1)010(2)(3)(4)
T419E156(1)010(2)(3)(4)
T419E226(1)010(2)(3)(4)
T419F336(1)010(2)(3)(4)
T419F476(1)010(2)(3)(4)
T419G476(1)010(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/11
Part Number
(See below for
part options)
CWR19C(3)335(1)(2)A(5)
CWR19C(3)475(1)(2)A(5)
CWR19C(3)685(1)(2)A(5)
CWR19C(3)106(1)(2)B(5)
CWR19C(3)156(1)(2)B(5)
CWR19C(3)226(1)(2)B(5)
CWR19C(3)226(1)(2)D(5)
CWR19C(3)336(1)(2)D(5)
CWR19C(3)336(1)(2)E(5)
CWR19C(3)476(1)(2)E(5)
CWR19C(3)686(1)(2)E(5)
CWR19C(3)107(1)(2)F(5)
CWR19C(3)157(1)(2)G(5)
CWR19C(3)227(1)(2)H(5)
CWR19C(3)337(1)(2)H(5)
CWR19D(3)335(1)(2)A(5)
CWR19D(3)475(1)(2)A(5)
CWR19D(3)685(1)(2)B(5)
CWR19D(3)106(1)(2)B(5)
CWR19D(3)156(1)(2)B(5)
CWR19D(3)156(1)(2)D(5)
CWR19D(3)156(1)(2)E(5)
CWR19D(3)226(1)(2)D(5)
CWR19D(3)226(1)(2)E(5)
CWR19D(3)336(1)(2)E(5)
CWR19D(3)476(1)(2)F(5)
CWR19D(3)686(1)(2)F(5)
CWR19D(3)686(1)(2)G(5)
CWR19D(3)107(1)(2)G(5)
CWR19D(3)157(1)(2)G(5)
CWR19D(3)227(1)(2)H(5)
CWR19D(3)337(1)(2)H(5)
CWR19F(3)225(1)(2)A(5)
CWR19F(3)335(1)(2)A(5)
CWR19F(3)475(1)(2)B(5)
CWR19F(3)475(1)(2)C(5)
CWR19F(3)685(1)(2)B(5)
CWR19F(3)685(1)(2)C(5)
CWR19F(3)685(1)(2)D(5)
CWR19F(3)106(1)(2)B(5)
CWR19F(3)106(1)(2)C(5)
CWR19F(3)106(1)(2)D(5)
CWR19F(3)106(1)(2)E(5)
CWR19F(3)156(1)(2)D(5)
CWR19F(3)156(1)(2)E(5)
CWR19F(3)226(1)(2)E(5)
CWR19F(3)336(1)(2)F(5)
CWR19F(3)476(1)(2)F(5)
CWR19F(3)476(1)(2)G(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Max/5 Min
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
3.0
4.0
6.0
8.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.8
4.0
4.0
6.0
10.0
10.0
20.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
3.0
3.0
4.0
4.0
µA @ +20ºC
Max/5 Min
DF
% @ 20ºC
120 Hz Max
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
6.0
8.0
6.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
% @ 20ºC
120 Hz Max
ESR
Ω @ +20ºC
100 kHz Max
12.0
12.0
12.0
8.0
8.0
8.0
4.0
4.0
3.0
3.0
3.0
2.0
1.0
1.0
0.9
12.0
12.0
8.0
8.0
8.0
5.0
3.0
5.0
3.5
3.5
3.5
1.5
1.0
1.1
1.1
0.9
0.9
12.0
12.0
8.0
5.5
8.0
5.5
5.0
8.0
5.5
4.0
3.5
5.0
3.0
2.0
1.5
1.5
1.0
Ω @ +20ºC
100 kHz Max
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated Cap
Case Code/
Case Size
KEMET Part Number
MIL–PRF–55365/11
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, C = -55°C +85°C before Weibull or Z = None. Designates Surge
current option.
Refer to Ordering Information for additional detail.
Live broadcast time:December 7, 2022 (Wednesday) 10:00-11:30 amLive Topic
Basic knowledge of data loggers, their applications and calibrationLive Broadcast Introduction
Analyze the structural characte...
I would like to share with you a little story I heard from teacher @maychang:Vicor CEO Patrizio Vinciarelli is a physicist with extensive teaching experience and industrial practice, and has been a le...
Embedded systems are used in a large number of electronic devices, and their design involves both hardware and software technology. As computer technology has advanced, its technology has become incre...
1. IntroductionFM33LG048 has one CNA (Controller Area Network) interface, supports CAN 2.0A and CAN 2.0B standards, supports 11-bit standard ID and 29-bit extended ID; the maximum transmission rate ca...
I don't know if you have ever encountered a bizarre incident where the code mysteriously disappeared, or a strange situation where the compiled code could not be used the next day. Today, I encountere...
1 Introduction
The main problems of street lighting in cities, especially small and medium-sized cities, are that the overall planning is lagging behind, the lighting control methods and man...[Details]
On the morning of March 18, DigiTimes, a media outlet that focuses on the industry chain, reported that Chinese display manufacturer BOE has established a partnership with touch screen manufac...[Details]
The dispute over the underlying technology route of smart cars is inevitably becoming one of the core issues of automotive intelligence. Earlier, the concept of smart cars was not yet popular, and ...[Details]
Sina Technology reported on the afternoon of May 8 that according to Taiwan's Economic Daily, Delta Electronics announced that its revenue in April was NT$23.425 billion (about RMB 5.13 billion...[Details]
On March 30, China's leading wafer foundry SMIC released its 2021 annual financial report. SMIC's total revenue in 2021 hit a record high of US$5.4431 billion, a year-on-year increase of 39.3%; profi...[Details]
LED dimming can further improve the energy-saving effect of LED, and LED thyristor dimming has a series of advantages such as easy implementation and easy use. The following introduces the working ...[Details]
Digital blogger @数码闲聊站 revealed three new flagship phones today. Judging from the comments, the new phones should refer to the Xiaomi 13 series. Xiaomi Mi 12 @数码闲聊站 said: "There are currentl...[Details]
Various
types The main feature of
low-frequency amplifiers
is that they have a wide operating frequency range, and the center frequency of the amplified signal ranges from tens of Hz to h...[Details]
On March 11, Li Ming, member of the Standing Committee of the Yangquan Municipal Party Committee and Secretary of the Pingding County Party Committee, led a team to Nanjing Wandes Environmental Protec...[Details]
Telephones and mobile phones are one of the most commonly used communication tools in modern life. If we can make good use of the telephone network and electronic technology, wireless communication, c...[Details]
CEVA Corporation announces CEO transition plan -Current CEO Gideon Wertheizer will retire at the end of the year -The board of directors appoints technology industry veteran Amir Panush as CEO...[Details]
All GPIOs of Exynos4412 have fixed addresses. To facilitate the operation of these GPIOs, the Linux kernel Some GPIO macros are defined in gpio-exynos4.h, for example: #define EXYNOS4_GPA0(_nr) (EXYN...[Details]
I'll sort it out, I don't know if I understand it correctly; /* BASIC INTERRUPT VECTOR TABLE FOR STM8 devices * Copyright (c) 2007 STMicroelectronics */ //typedef void (*)void,; define a type (pointe...[Details]
The Delixi inverter EM60 is a high-performance inverter widely used in the field of industrial automation. It has a variety of functions and features to meet the needs of different industries and a...[Details]