EEWORLDEEWORLDEEWORLD

Part Number

Search

MPO-25S-48

Description
Single Output, 25W Compact, Open Frame AC/DC Power Supplies
File Size219KB,2 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet Compare View All

MPO-25S-48 Overview

Single Output, 25W Compact, Open Frame AC/DC Power Supplies

MPO-25S
Series
Si l O
Single Output, 25W
2
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
25W Output Power
Universal 90-264 AC Input
EN 60950 Compliant
Low Leakage Current
Nine Single Output Models
Meets EN55022
>500 kHour MTBF
Only 4.2” x 2.4” x 1.1”
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Safety Ground Leakage Current
Conditions
Min.
Typ.
90
127
47
See Model Selection Guide
Cold Start, 115 VAC
20.0
Cold Start, 230 VAC
36.0
115 VAC
0.35
240 VAC
0.5
Universal
Max.
264
370
63
Units
VAC
VDC
Hz
A Pk
mA
Units
Output
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
Set-Up Time
Rise Time
Conditions
Min.
Typ.
Max.
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
115 VAC
20
230 VAC
100
115/230 VAC
200
115 VAC
30
230 VAC
20
±0.02
Continuous (Autorecovery)
See Note 3 115
135
See Note 4 105
See Note 5
U1 >135 °C
Conditions
Input to Output
Input to Ground
Output to Ground
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
Conditions
Min.
3,000
1,500
500
Typ.
Max.
mSec
mSec
mSec
%/°C
%
%
RoHS Compliant
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Over Temperature
General
Parameter
Isolation Voltage
Isolation resistance
EMI/RFI
EMC Compliance
Switching Frequency
Units
VAC
100
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
100
kHz
Units
°C
°C
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Min.
Typ.
Max.
Ambient
-10
+25
+60
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Physical
Size
Weight
4.2 x 2.4 x 1.1 Inches (107.0 x 67.0 x 28.0 mm)
4.9 Oz (0.14 kg)
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
300
kHours
IEN 60950, IEC 60950
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration

MPO-25S-48 Related Products

MPO-25S-48 MPO-25S-12 MPO-25S-13.5 MPO-25S-15 MPO-25S-24 MPO-25S-27
Description Single Output, 25W Compact, Open Frame AC/DC Power Supplies Single Output, 25W Compact, Open Frame AC/DC Power Supplies Single Output, 25W Compact, Open Frame AC/DC Power Supplies Single Output, 25W Compact, Open Frame AC/DC Power Supplies Single Output, 25W Compact, Open Frame AC/DC Power Supplies Single Output, 25W Compact, Open Frame AC/DC Power Supplies
【Goodbye 2021, Hello 2022】Let’s practice together in 2022: Looking back at 2021 and looking forward to 2022
Before I knew it, another year had passed. I looked at it and found that I had also recorded a five-year summary on the forum. Looking back over the past five years, I have grown a lot.In 2021, I fina...
RCSN Talking
ZigBee Protocol Stack
TI released the ZigBee protocol stack based on CC2530[/font][/size][/color] [font=MicrosoftYaHei][color=#252525][size=14px][color=#999999]ZStack-CC2530-2.5.1a.exe[/color][/size][/color][/font] [font=M...
HangYongmao RF/Wirelessly
EEWORLD University ---- Fundamentals of VLSI Design (Fundamentals of Digital Integrated Circuit Design) (Southeast University)
Fundamentals of VLSI Design (Fundamentals of Digital Integrated Circuit Design) (Southeast University) : https://training.eeworld.com.cn/course/6103? ?This course is the core course of microelectronic...
木犯001号 Embedded System
As long as your phone is not upgraded, it will not lag! How often do you change your phone now?
Someone complained that the configuration of the phone could not keep up with the times, and asked Luo if he had re-entered the market when the Nut Phone R1 (launched in 2018) became laggy. Luo replie...
eric_wang Talking
CH340 circuit to prevent current backflow
[size=4][color=#000000][backcolor=white] In actual applications, when CH340 is used with other ICs such as MCU, if one of the two devices directly connected by the serial port does not need power to w...
fish001 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号