Part Number

Search

205-P

Description
3 1/2 DIGIT MINI-SIZE PROCESS METER
File Size526KB,2 Pages
ManufacturerETC2
Download Datasheet Compare View All

205-P Overview

3 1/2 DIGIT MINI-SIZE PROCESS METER

SAFETY CONSIDERATIONS
This device is marked with the international Caution, risk of danger symbol. It is
important to read this manual before installing or commissioning this device as it
contains important information relating to Safety and EMC (Electromagnetic
Compatibility).
Unpacking & Inspection
Unpack the instrument and inspect for obvious shipping damage. Do not attempt
to operate the unit if damage is found.
This instrument is a DIN rail mount device. Installation of this instrument should
be done by Qualified personnel. In order to ensure safe operation, the following
instructions should be followed.
This instrument has no power-on switch. An external switch or circuit-breaker shall be
included in the building installation as a disconnecting device. It shall be marked to indicate
this function, and it shall be in close proximity to the equipment within easy reach of the
operator. The switch or circuit-breaker shall not interrupt the Protective Conductor (Earth
wire), and it shall meet the relevant requirements of IEC 947–1 and IEC 947-3 (International
Electrotechnical Commission). The switch shall not be incorporated in the mains supply cord.
Furthermore, to provide protection against excessive energy being drawn from the mains
supply in case of a fault in the equipment, an overcurrent protection device shall be installed.
• The
Protective Conductor
must be connected for safety reasons. Check
that the power cable has the proper Earth wire, and it is properly connected. It is
not safe to operate this unit without the Protective Conductor Terminal
connected.
• Do not exceed voltage rating on the label located on the top of the instrument
housing.
• Always disconnect power before changing signal and power connections.
• Do not use this instrument on a work bench without its case for safety reasons.
• Do not operate this instrument in flammable or explosive atmospheres.
• Do not expose this instrument to rain or moisture.
• Unit mounting should allow for adequate ventilation to ensure instrument does
not exceed operating temperature rating.
• Use electrical wires with adequate size to handle mechanical strain and power
requirements. Install without exposing bare wire outside the connector to
minimize electrical shock hazards.
EMC Considerations
• Whenever EMC is an issue, always use shielded cables.
• Never run signal and power wires in the same conduit.
• Use signal wire connections with twisted-pair cables.
• Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems
persist.
PANEL CUTOUT
2.677 +0.028/-.000
[68.00 +0.70/-0.00]
WIRING
AC POWER WIRING
Connect the ac main power connections as shown below.
EARTH
NEUTRAL
LINE
RANGE SELECTION
R 0.06 [1.5]
4 PLCS
0.874 +.012/-.000
[22.20 +0.30/-0.00]
GREEN WIRE
N
L
SWITCH
Check for proper Earth grounding in the
power distribution system (single phase).
FUSE
5
6
7
P1
ORANGE
CONNECTOR
Screws
underneath
PANEL THICKNESS
0.25 [6.4] MAX
0.03 [0.8] MIN
DIMENSIONS
0.945 [24.00]
0.197
[5.00]
2.835
[72.00]
CAUTION:
Do not connect ac power to your meter until you
have completed all input and output connections. Failure to
do so may result in injury! This device must only be installed
electrically by specially trained electrician with
corresponding qualifications. The main power input to the
unit as well as the AC input signal to be measured must
agree with the wiring instruction.
The meter is factory set to the power specified by the customer at the
time of ordering. The voltage is printed on the label under Input
power.
To connect power to the unit, attach wires, as shown from the ~AC
power cord to the orange 3-pin female connector that is supplied with
the meter. Plug the female connector into the orange P1 (male)
connector at the rear of the meter.
DC POWER WIRING
The meter can be
No Connection N/C
External + DC
configured at the
Power
factory to operate on DC
Supply
– DC
non-isolated power. The
DC voltage option is
specified at the time of
ordering. An AC powered meter
cannot be converted to a DC
powered meter or vice versa.
CURRENT / VOLTAGE INPUT 205-P & -E
4-20 mA
0-0.2 V dc
1-5 V dc
0-10 V dc
0-100 V dc
VOLTAGE INPUT RANGE 205-A
±199.9 mV dc
±1.999 V dc
±19.99 V dc
±100.0 V dc
EXCITATION VOLTAGE 205-E ONLY
10 V, (standard internal reference)
24 V, (standard internal reference)
10 V, (reference based on excitation voltage)
S3
D, E
E
A
B
C
S3
-
A
B
C
S2
B, D
B, D
A, C
S4
A
-
A
4.134
[105.00]
4.60
[116.8]
INSTALLATION
1.
Unpack and verify that all equipment has been received. If there
are any questions about the shipment, contact the service
department nearest you.
Cut or punch a hole in the panel where you want the meter to go.
Remove the lens by inserting a paper clip or small flat screwdriver
into the rounded corner of the lens and lift out.
Remove the two mounting screws from both sides of display. Pry
both sides of the mounting clamp
out and down
to remove it from
the case.
Insert the meter into the panel cutout and reinstall the mounting
clamp from the rear.
Reinstall the mounting screws to secure the meter into the panel.
Do not overtighten the screws.
Pop the lens back in, making sure the dull side of the lens faces
towards you.
PANEL CUTOUT
0.858 [21.80]
SIDE VIEW
2.661
[67.60]
TOP VIEW
5
P1
Voltage operation was configured per customer order. 115 and
230 Vac operation use the same transformer and may be reversed
with simple wiring installation.
ORANGE
CONNECTOR
6
All dimensions are in inches [millimeters].
7
Screws
underneath
CAUTION:
Disconnect power before attempting to convert or
remove the unit.
You must remove the printed circuit board from the case in order to
change from 115 Vac to 230 Vac (and vice versa). These changes
must be performed by a qualified technician in order to avoid damage
TRANSFORMER # AC VOLTAGE
48131
115 Vac
48131
230 Vac
INSTALL
W1, W3
W2
REMOVE
W2
W1, W3
2.
3.
4.
REMOVING BOARD FROM CASE
PULL TAB HERE
PC BOARD
PUSH BOARD ASS'Y FROM HERE
To connect power to the unit, attach wires, as shown, to the orange 3-
pin female connector that is supplied with the meter. Plug the female
connector into the orange P1 (male) connector at the rear of the
meter.
SIGNAL INPUT WIRING 205-E
5.
6.
7.
1
2
3
4
5
6
7
Current
Transmitter
–+
+ EXC
Sig Hi
Sig Lo
CALIBRATION / 205-P & 205-E
1.
1
P1
REAR OF CASE
– EXC
2.
2
3
P1
CASE
4
3.
ELECTRICAL CONNECTIONS
POWER AND SIGNAL INPUT
~
AC POWER
= DC POWER
205-E
205-P & 205-A 205-P & 205-A
SIG HI (+S)
SIG LO (-S)
+ Exc
- Exc
AC Earth GND (©)
AC Neutral (N)
AC Line (L)
SIG HI (+S)
SIG LO (-S)
Hold
Digital Return
AC Earth GND ( )
AC Neutral (N)
AC Line (L)
SIG HI (+S)
SIG LO (-S)
Hold
Digital Return
-DC (-)
+ DC (+)
No Connection (N/C)
Current
+
OR
Voltage
~
Screws
underneath
Apply the minimum current or voltage to the signal input.
Adjust the zero pot for the minimum display reading ±1 count.
Apply the maximum current or voltage to the signal input.
Adjust the span pot for the maximum display reading ±1 count.
Repeat steps 1 and 2 until ±1 count desired reading. Reinstall the
lens.
CALIBRATION / 205-A
1.
2.
3.
Apply a voltage equivalent to 95% of the range selected to the
signal input.
Adjust the span pot for a reading of 1900 ±1 count.
Reinstall the lens.
Decimal
Point
S1
ZERO
SPAN
Z
S
SIGNAL INPUT WIRING 205-P & 205-A
Hold
Switch
Digital Return
+
DC Current
DC Voltage
P1
1
2
3
4
MOUNTING CLAMP
MOUNTING SCREW (2)
1
2
LENS
5
6
7
3
P1
A
B
4
Screws
underneath
S1
C
S1
1.999
19.99
199.9
1999
A
B
C
Store jumper
above A

205-P Related Products

205-P 205-A 205-E
Description 3 1/2 DIGIT MINI-SIZE PROCESS METER 3 1/2 DIGIT MINI-SIZE PROCESS METER 3 1/2 DIGIT MINI-SIZE PROCESS METER
Who can help me make a simple counter model?
I need a circuit board model that can count, and I can modify it myself....
异地暖和 Sensor
How much is a person who understands hardware + PCB design + Linux + FPGA worth?
How much is a person who knows hardware + PCB design + Linux + FPGA worth? I am preparing to learn Linux and FPGA, and I want to know what the general market price of such a person is...
lingking Talking about work
lpc824 save the brick!!!
Last night, I accidentally modified the SWM_FIXED_SWCLK pin, and the lpc824 board became a brick. I would like to ask for your advice. The board SWD pins are SWM_FIXED_SWCLK and SWM_FIXED_SWDIO, which...
bigbat NXP MCU
Diode limiter circuit
Diode limiter circuit We often see combination circuits of diodes. These five circuits may not have practical significance, but they can be analyzed! What are the output voltage ranges of OUT1-OUT5? (...
QWE4562009 Discrete Device
Can I put port p0 in an array?
I want to ask if it is possible to put a group of io ports, such as port p0, in an array. It would be more convenient to use for to write a flow light. If so, how should I define the array?...
cheepy 51mcu
Several minor issues in DSP debugging process
1. Pay attention to the address allocation and make sure there is enough space.2. In RAM, an error occurs:C28xx: Trouble Setting Breakpoint with the Action "Finish Auto Run" at 0x223db3: (Error -1066 ...
Jacktang DSP and ARM Processors

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号