EEWORLDEEWORLDEEWORLD

Part Number

Search

ASDXACX002BGAA5

Description
GAGE, STRAIN GUAGE PRESSURE SENSOR, RECTANGULAR, THROUGH HOLE MOUNT
CategoryThe sensor   
File Size307KB,6 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

ASDXACX002BGAA5 Overview

GAGE, STRAIN GUAGE PRESSURE SENSOR, RECTANGULAR, THROUGH HOLE MOUNT

ASDXACX002BGAA5 Parametric

Parameter NameAttribute value
Maximum supply voltage5.25 V
Minimum supply voltage4.75 V
Maximum operating temperature105 Cel
Minimum operating temperature-20 Cel
Processing package descriptionROHS COMPLIANT, PACKAGE-8
stateACTIVE
width14.02 mm
Installation featuresTHROUGH HOLE MOUNT
Terminal typeSOLDER
Working current3.5 mA
type of packagingRECTANGULAR
length or diameter16.81 mm
Number of digits12
Output typeANALOG VOLTAGE
port typeSTRAIGHT
Pressure sensing modeGAGE
Response time1000 ms
sensor typeSTRAIN GUAGE
ASDX Series Silicon
Pressure Sensors
Low Pressure and Ultra-Low
Pressure Analog Output
±2% Total Error Band, DIP,
10 inches H
2
0 to 100 psi
DESCRIPTION
The ASDX Series is a Silicon Pressure Sensor offering a
ratiometric analog output for reading pressure over the
specified full scale pressure span and temperature range.
The ASDX is fully calibrated and temperature compensated for
sensor offset, sensitivity, temperature effects and non-linearity
using an on-board Application Specific Integrated Circuit
(ASIC). Calibrated output values for pressure are updated at
approximately 1 kHz.
The standard ASDX is calibrated over the temperature range
of 0 °C to 85 °C [32 °F to 185 °F]. The sensor is characterized
for operation from a single power supply of either 3.3 Vdc or
5.0 Vdc.
FEATURES
Ratiometric 12-bit analog output
Precision ASIC conditioning and temperature
compensated over 0 °C to 85 °C [32 °F to 185 °F]
temperature range
Low operating voltage
Absolute, differential and gage types
Pressure ranges from 10 inches H
2
0 to 100 psi
Standard calibrations in inches H
2
0, cm H
2
0, psi, mbar,
bar, kPa
Total error band of ±2.0% of full scale span maximum
RoHS compliant
These sensors are available to measure absolute, differential
and gage pressures. The absolute versions have an internal
vacuum reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
The ASDX Series sensors are intended for use with non-
corrosive, non-ionic working fluids such as air and dry gases.
They are designed and manufactured according to standards
in ISO 9001.
POTENTIAL APPLICATIONS
Flow calibrators
Ventilation and air flow monitors
Gas flow instrumentation
Sleep apnea monitoring and therapy equipment
Barometry
Pneumatic controls
HVAC
Problems with STM32F4 serial port 4 standard library program
There is a board, STM32F407VET6, serial port 4 is connected to PC10 and PC11.I wrote a program using the standard library, but it can't communicate. The initialization code is as follows://IO 4 //boun...
chenbingjy stm32/stm8
Recruiting part-time dsp training instructors
Now recruiting part-time dsp lecturers. Short-term training can be done on weekends. If you want to earn some extra money, accumulate resources, and enrich your life, please contact me.Require: ① More...
zkxr20 Recruitment
Software platform installation for SILICON LABS PG22-DK2503A development board
Enter SILICON LABS official website: https://cn.silabs.com/development-tools/mcu/32-bit/efm32pg22-development-kit Then select "Get Started"on the web pageand download and installSimplicity Studio vers...
cjjh2014 Development Kits Review Area
CCS CMD file invalidation causes memory allocation failure
The C6678.cmd file is grayed out for some reason. I didn't notice it at first, but when I compiled the project, I found that all memory allocated in DDR failed. Is it possible that my cmd file is not ...
Aguilera DSP and ARM Processors
[ADI Practical Knowledge Sharing] The hidden costs of isolation system design cannot be ignored!
[align=left] [color=#3d3d3d][font="][size=10.5pt]Click here to download the handouts for this seminar: [/size][/font][/color][/align][align=left][b]https://ez.analog.com/cn/webcasts/f/forum/109744/thr...
电路艺术 ADI Reference Circuit
EEWORLD University - Amplifier Design in Test and Measurement
Amplifier Design in Test and Measurement : https://training.eeworld.com.cn/course/5700...
hi5 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号