760185199 | D-036-LN-8W-F06NS/HD
TeraSPEED® Single Jacket All-Dielectric, Gel-Free, Outdoor Stranded
Loose Tube Cable w/HDPE Outer Jacket
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber OSP cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
Cable Qualification Standards
ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20
Representative Image
General Specifications
Cable Type
Construction Type
Subunit Type
Stranded loose tube
Non-armored
Gel-free
Construction Materials
Fiber Type Solution
Jacket Material
G.652.D and G.657.A1 , TeraSPEED® | OS2
High density polyethylene (HDPE)
page 1 of 3
March 27, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
760185199 | D-036-LN-8W-F06NS/HD
Total Fiber Count
Fiber Type
Fiber Type, quantity
Fibers per Subunit, quantity
Jacket Color
Jacket UV Resistance
36
G.652.D and G.657.A1, TeraSPEED® | OS2
36
6
Black
UV stabilized
Dimensions
Buffer Tube/Subunit Diameter
Cable Weight
Diameter Over Jacket
Filler, quantity
Subunit, quantity
2.50 mm | 0.10 in
70.0 kg/km | 47.0 lb/kft
10.50 mm | 0.41 in
0
6
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
15.8 cm | 6.2 in
10.5 cm | 4.1 in
Tensile Load, long term, maximum
800 N | 180 lbf
Tensile Load, short term, maximum
2700 N | 607 lbf
Vertical Rise, maximum
1164.0 m | 3819.0 ft
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Aerial, lashed | Buried
-30 °C to +70 °C (-22 °F to +158 °F)
-40 °C to +70 °C (-40 °F to +158 °F)
-40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
Impact Test Method
Strain
Strain Test Method
Twist
Twist Test Method
Water Penentration
22 N/mm | 125 lb/in
FOTP-41 | IEC 60794-1 E3
35 cycles
FOTP-104 | IEC 60794-1 E6
4.41 N-m | 3.25 ft lb
FOTP-25 | IEC 60794-1 E4
See long and short term tensile loads
FOTP-33 | IEC 60794-1 E1
10 cycles
FOTP-85 | IEC 60794-1 E7
24 h
page 2 of 3
March 27, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
760185199 | D-036-LN-8W-F06NS/HD
Water Penentration Test Method
FOTP-82 | IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze
Cable Freeze Test Method
Heat Age
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-2 °C | 28 °F
FOTP-98 | IEC 60794-1 F15
-40 °C to +85 °C (-40 °F to +185 °F)
IEC 60794-1 F9
-30 °C to +60 °C (-22 °F to +140 °F)
FOTP-37 | IEC 60794-1 E11
-40 °C to +70 °C (-40 °F to +158 °F)
FOTP-3 | IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
Included Products
CS -8W-LT (Product Component—not orderable)
—
TeraSPEED ® OS2 Singlemode Fiber
CS-8W-
Component—
TeraSPEED®
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 27, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018