HBS050YH-AN82V

Description
DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid
CategoryPower/power management    The power supply circuit   
File Size88KB,3 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

HBS050YH-AN82V Overview

DC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid

HBS050YH-AN82V Parametric

Parameter NameAttribute value
Brand NamePower-One
MakerBel Fuse
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSETPOINT ACCURACY:+/-1%
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage36 V
Minimum input voltage18 V
Nominal input voltage24 V
JESD-30 codeR-XUFM-P9
Maximum load regulation0.2%
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature100 °C
Minimum operating temperature-40 °C
Maximum output voltage13.2 V
Minimum output voltage10.8 V
Nominal output voltage12 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formFLANGE MOUNT
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelINDUSTRIAL
Terminal formPIN/PEG
Terminal locationUPPER
Maximum total power output50 W
Fine-tuning/adjustable outputYES
HBS50 DC-DC Series Data Sheet
50-Watt Half-Brick
EFFICIENCY %
Description
HBS dc-dc converters provide up to 50 watts of output
power in an industry-standard, half-brick footprint. The
HBS units feature excellent efficiency, Class A conducted
noise specs, and fixed switching frequency. The HBS,
using open-frame packaging, along with planar magnetics
provides maximum useable power with minimal thermal
constraints. The HBS Series is especially suited to
telecom, networking, and industrial applications.
Features
• Industry-standard half-brick
• Open-frame packaging
• 100°C baseplate operation
• Water washable
• “True-trim” option
• 1500V isolation
• Positive or negative logic
Efficiency vs. Load (24V Input)
95
90
85
80
75
70
65
HBS050YG-A
HBS050YH-A
HBS050YJ-A
Technical Specifications
Input
Voltage Range
24 VDC nominal
48 VDC nominal
Reflected Ripple
Input Reverse Voltage Protection
Output
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Remote Sense Headroom
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
OVP Trip Range
OVP
Notes
MTBF predictions may vary slightly from model to model.
60
10
20
30
40
50
60
70
80
90
100
LOAD %
18 - 36 VDC
34 - 75 VDC
25 mA
Shunt Diode
95
90
Efficiency vs. Load (48V Input)
±1%
±0.2% Vout
±0.2% Vout
0.5 VDC
10%, Iout Rated
25% Iout
4% Vout
500 ms
±10%
Hiccup
110 - 140%
115 - 140% Vout Nom.
Hiccup
85
80
75
70
65
60
10
20
30
40
50
60
70
80
90
100
LOAD %
HBS050ZG-A
HBS050ZH-A
HBS050Z10.5-A
General
Turn-On Time
Remote Shutdown
Remote Shutdown Reference
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Weight (approx.)
10 ms
Positive or Negative Logic
Vin Negative
500 kHz
1500 VDC
1050 VDC
500 VDC
0.2%/°C
-40 to +100°C
-40 to +125°C
105 to 115°C
5 g, 10 - 55 Hz
2.1 x 106 hrs
UL, cUL
2.5 oz
Specifications typically at 25°C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
REV. JUN 04, 2004
Page 1 of 3
[Runhe Neptune Review] Five PWM
PWM: Pulse Width Modulation It is to periodically control the time (duty cycle) of IO pulling high and low to control the on and off of the switch tube to achieve power control, such as LED dimming, D...
hl23889909 Real-time operating system RTOS
How to use the wireless transceiver module
How to use the wireless transceiver module  How to use the wireless transceiver module? Which frequency of the wireless transceiver module is better, 2.4G, 315MHz or 433MHz? This is a question that ma...
灞波儿奔 RF/Wirelessly
Understanding of MSP430G2553
Looking back on the period before school started, it seems that I didn’t do anything except learning MSP430G2553.The software used is CCS. Installing the software is really a headache. I installed it ...
fish001 Microcontroller MCU
PT1000 circuit help
X1 is a PT1000 external resistor, the temperature is -40°-180°. The error is about plus or minus 1°C. How can I modify it to reduce the error?...
常伴久久 PCB Design
Brief analysis of the working principle of DSP
There are two ways to understand DSP:  1) Broadly speaking: digital signal processing;  it uses a digital signal processing system to process signals in digital form, and finally obtains a signal form...
Aguilera DSP and ARM Processors

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号