GSX-11/351F350.0MHZ

Description
Parallel - 3Rd Overtone Quartz Crystal, 50MHz Nom,
CategoryPassive components    Crystal/resonator   
File Size55KB,1 Pages
ManufacturerGolledge Electronics
Websitehttp://www.golledge.com/
Environmental Compliance  
Download Datasheet Parametric View All

GSX-11/351F350.0MHZ Overview

Parallel - 3Rd Overtone Quartz Crystal, 50MHz Nom,

GSX-11/351F350.0MHZ Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGolledge Electronics
Reach Compliance Codecompliant
Other featuresTAPE AND REEL
Ageing5 PPM/FIRST YEAR
Crystal/Resonator TypePARALLEL - 3RD OVERTONE
Drive level100 µW
frequency stability0.005%
frequency tolerance30 ppm
JESD-609 codee4
load capacitance20 pF
Manufacturer's serial numberGSX-11
Installation featuresSURFACE MOUNT
Nominal operating frequency50 MHz
Maximum operating temperature60 °C
Minimum operating temperature-10 °C
physical sizeL12.1XB5.8XH2.1 (mm)
Series resistance100 Ω
surface mountYES
Terminal surfaceGold (Au)
Samsung's 7LPP EUV process has another big move
Synopsys Fusion Technology Helps Samsung's 7LPP EUV Process Reduce Power, Reduce Area and Improve Performance[/size][/url][/align] [align=left][b][size=3]Highlights:[/size][/b][/align][list] [*][size=...
muyankop PCB Design
Selling Zedboard Zynq7020 development board
[i=s]This post was last edited by fjjjnk1234 on 2020-10-18 11:30[/i]Zedboard development board, compatible with the official Zedboard Chip model: Zynq-7020-CLG 484-2I Condition: 95% new or above Acces...
fjjjnk1234 Buy&Sell
I have to say that the old technology I have been exposed to since 2008 was still blocked at that time.
1-3. Input and output matching circuit The purpose of the matching circuit is to choose a way of acceptance. For those transistors that want to provide greater gain, the way is to accept and output it...
btty038 RF/Wirelessly
Calibration of medical devices
Calibration of medical devices 1. Thermometer calibration - use black body furnace + constant temperature water bath to calibrate two points 2. Sphygmomanometer calibration - using BP pump sphygmomano...
QWE4562009 Test/Measurement
Search engine technology and trends
[From Search Engine Direct] With the rapid development of the Internet and the increase of web information, users need to find information in the ocean of information, which is like looking for a need...
feifei Talking
Doesn't high input impedance mean high loss? Why does sampling require high input impedance? Low output impedance, such as running...
Doesn't high input impedance mean high loss? Why does sampling require high input impedance? Low output impedance, such as an op amp circuit...
QWE4562009 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号