TRIAC, 400V V(DRM), 1A I(T)RMS, TO-92,
Parameter Name | Attribute value |
Maker | Hutson Industries |
package instruction | CYLINDRICAL, O-PBCY-W3 |
Reach Compliance Code | unknown |
Other features | SENSITIVE GATE |
Configuration | SINGLE |
Critical rise rate of commutation voltage - minimum value | 1 V/us |
Critical rise rate of minimum off-state voltage | 10 V/us |
Maximum DC gate trigger current | 3 mA |
Maximum DC gate trigger voltage | 2 V |
Maximum holding current | 5 mA |
JEDEC-95 code | TO-92 |
JESD-30 code | O-PBCY-W3 |
Number of components | 1 |
Number of terminals | 3 |
Maximum operating temperature | 110 °C |
Minimum operating temperature | -40 °C |
Package body material | PLASTIC/EPOXY |
Package shape | ROUND |
Package form | CYLINDRICAL |
Certification status | Not Qualified |
Maximum rms on-state current | 1 A |
Maximum repetitive peak off-state leakage current | 100 µA |
Off-state repetitive peak voltage | 400 V |
surface mount | NO |
Terminal form | WIRE |
Terminal location | BOTTOM |
Trigger device type | TRIAC |
TDSA | TDHA | TMGA | TMHA | TBHA | TBSA | TDDA | TDGA | TMDA | TMSA | |
---|---|---|---|---|---|---|---|---|---|---|
Description | TRIAC, 400V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 400V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 600V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 600V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 200V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 200V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 400V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 400V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 600V V(DRM), 1A I(T)RMS, TO-92, | TRIAC, 600V V(DRM), 1A I(T)RMS, TO-92, |
Maker | Hutson Industries | Hutson Industries | Hutson Industries | Hutson Industries | Hutson Industries | Hutson Industries | Hutson Industries | Hutson Industries | Hutson Industries | Hutson Industries |
package instruction | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 | CYLINDRICAL, O-PBCY-W3 |
Reach Compliance Code | unknown | unknown | unknown | unknown | unknown | unknown | unknown | unknown | unknown | unknown |
Other features | SENSITIVE GATE | SENSITIVE GATE | SENSITIVE GATE | SENSITIVE GATE | SENSITIVE GATE | SENSITIVE GATE | SENSITIVE GATE | SENSITIVE GATE | SENSITIVE GATE | SENSITIVE GATE |
Configuration | SINGLE | SINGLE | SINGLE | SINGLE | SINGLE | SINGLE | SINGLE | SINGLE | SINGLE | SINGLE |
Critical rise rate of commutation voltage - minimum value | 1 V/us | 1 V/us | 1 V/us | 1 V/us | 1 V/us | 1 V/us | 1 V/us | 1 V/us | 1 V/us | 1 V/us |
Critical rise rate of minimum off-state voltage | 10 V/us | 25 V/us | 20 V/us | 25 V/us | 25 V/us | 10 V/us | 10 V/us | 20 V/us | 10 V/us | 10 V/us |
Maximum DC gate trigger current | 3 mA | 25 mA | 10 mA | 25 mA | 25 mA | 3 mA | 5 mA | 10 mA | 5 mA | 3 mA |
Maximum DC gate trigger voltage | 2 V | 2 V | 2 V | 2 V | 2 V | 2 V | 2 V | 2 V | 2 V | 2 V |
Maximum holding current | 5 mA | 25 mA | 15 mA | 25 mA | 25 mA | 5 mA | 10 mA | 15 mA | 10 mA | 5 mA |
JEDEC-95 code | TO-92 | TO-92 | TO-92 | TO-92 | TO-92 | TO-92 | TO-92 | TO-92 | TO-92 | TO-92 |
JESD-30 code | O-PBCY-W3 | O-PBCY-W3 | O-PBCY-W3 | O-PBCY-W3 | O-PBCY-W3 | O-PBCY-W3 | O-PBCY-W3 | O-PBCY-W3 | O-PBCY-W3 | O-PBCY-W3 |
Number of components | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Number of terminals | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Maximum operating temperature | 110 °C | 110 °C | 110 °C | 110 °C | 110 °C | 110 °C | 110 °C | 110 °C | 110 °C | 110 °C |
Minimum operating temperature | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C |
Package body material | PLASTIC/EPOXY | PLASTIC/EPOXY | PLASTIC/EPOXY | PLASTIC/EPOXY | PLASTIC/EPOXY | PLASTIC/EPOXY | PLASTIC/EPOXY | PLASTIC/EPOXY | PLASTIC/EPOXY | PLASTIC/EPOXY |
Package shape | ROUND | ROUND | ROUND | ROUND | ROUND | ROUND | ROUND | ROUND | ROUND | ROUND |
Package form | CYLINDRICAL | CYLINDRICAL | CYLINDRICAL | CYLINDRICAL | CYLINDRICAL | CYLINDRICAL | CYLINDRICAL | CYLINDRICAL | CYLINDRICAL | CYLINDRICAL |
Certification status | Not Qualified | Not Qualified | Not Qualified | Not Qualified | Not Qualified | Not Qualified | Not Qualified | Not Qualified | Not Qualified | Not Qualified |
Maximum rms on-state current | 1 A | 1 A | 1 A | 1 A | 1 A | 1 A | 1 A | 1 A | 1 A | 1 A |
Maximum repetitive peak off-state leakage current | 100 µA | 100 µA | 100 µA | 100 µA | 100 µA | 100 µA | 100 µA | 100 µA | 100 µA | 100 µA |
Off-state repetitive peak voltage | 400 V | 400 V | 600 V | 600 V | 200 V | 200 V | 400 V | 400 V | 600 V | 600 V |
surface mount | NO | NO | NO | NO | NO | NO | NO | NO | NO | NO |
Terminal form | WIRE | WIRE | WIRE | WIRE | WIRE | WIRE | WIRE | WIRE | WIRE | WIRE |
Terminal location | BOTTOM | BOTTOM | BOTTOM | BOTTOM | BOTTOM | BOTTOM | BOTTOM | BOTTOM | BOTTOM | BOTTOM |
Trigger device type | TRIAC | TRIAC | TRIAC | TRIAC | TRIAC | TRIAC | TRIAC | TRIAC | TRIAC | TRIAC |