M2000 series
H2000 series
VCXO 5.0V
Full/Half size, Thru-hole, HCMOS/TTL
Features
RoHS Status
Frequency from 1 MHz to 175 MHz
Start-up time is less than 5ms
Applications
xDSL customer premise equipment
Cable modems
ATM/SONET/SDH
Electrical Specifications
Parameter
Frequency Range
Frequency Stability
Aging
Operating
Temperature
Supply Voltage
Supply Current
Output Levels
Rise & Fall Times
Input Impedance
Start-up Time
Symmetry
Control Voltage
Bandwidth
Ts
@ V
DD
/2
15
150
T
Vcc
Icc
“0” Level, sinking 16mA
“1” Level, sourcing 10mA
From 0.4 to (V
DD
-.4) V
(Above 35 MHz)
Symbol
F
∆F/F
Condition
Operating Temperature at 25°C
First Year
After First Year
Min
1
±
20
Typ
±
25
3
1
Max
175
±
50
Unit
MHz
ppm
ppm
ppm/yr
Note
0°
4.5
5.0
30
V
DD
-0.4
2.5
15
1000
+70°
5.5
45
0.4
4
2
°C
V
mA
V
ns
KOhm
Control voltage
5
45/55
ms
%
KHz
75 South Street, Hopkinton, MA 01748 • 800-982-5737 • 508-497-6377 • FAX 508-435-5289 • www.valpeyfisher.com • RevA_1007
1
M2000 series
H2000 series
VCXO 5.0V
Full/Half size, Thru-hole, HCMOS/TTL
Environmental and Mechanical Conditions
Parameter
Shock
Vibration
Humidity
Gross Leak
Fine Leak
Pins
Bend Test
Header
Case
Marking
Resistance to Solvents
Center Frequency is Between Two Voltages
M2001, H2001
M2002, H2002
M2003, H2003
Specification
1000 Gs, 0.35 ms, 1/2 sine wave, 3 shocks in each plane
10-2000 Hz of .06" d.a. or 20 Gs, whichever is less
Resistant to 85° R.H. at 85°C
Each unit checked in 125°C fluorocarbon
Mass spectrometer leak rate less than 2 X 10
-8
atm, cc/sec of helium
Kovar, nickel plated with 60/40 solder coat
Will withstand two bends of 90° from reference
Steel, with nickel plate
Stainless steel, type 304
Printing is black epoxy ink or laser marked
MIL STD 202, Method 215
DESCRIPTIONS
±175 ppm, min. deviation
when using 0.3 to 10V control-voltage
±75 ppm, min. deviation
when using 0.3 to 4.0V control-voltage
±175 ppm to ±300 ppm deviation when using
0.3 to 10V control-voltage
±125 ppm min. deviation
when using 0.3 to 4.0V control-voltage
±75 ppm to ±300 ppm deviation when using
1.0 to 4.0V control-voltage, for use where the
control voltage is 1 volt off both rails
±150 ppm, min. deviation when using
0 to 5.0V rail-to-rail control-voltage
±125 ppm to ±250 ppm deviation when using
0.5 to 4.5V control-voltage
±75 ppm capture when using using 0.5 to 4.5V
control-voltage and 2.5V center with ±50 ppm
stability
±100 ppm capture when using using 0.5 to 4.5V
control-voltage and 2.5V center with ±50 ppm
stability
±150 ppm capture when using using 0.5 to 4.5V
control-voltage and 2.5V center with ±50 ppm
stability
±75 ppm capture when using using 0.5 to 4.5V
control-voltage and 2.5V center with ±25 ppm
stability
±100 ppm capture when using using 0.5 to 4.5V
control-voltage and 2.5V center with ±25 ppm
stability
±150 ppm capture when using using 0.5 to 4.5V
control-voltage and 2.5V center with ±25 ppm
stability
M2004, H2004
M2005, H2005
M2006, H2006
M2007, H2007
Center Frequency is at 2.5V with ±50 ppm stability
M2021, H2021
M2022, H2022
M2023, H2023
M2031, H2031
M2032, H2032
M2033, H2033
Center Frequency is at 2.5V with ±25 ppm stability
75 South Street, Hopkinton, MA 01748 • 800-982-5737 • 508-497-6377 • FAX 508-435-5289 • www.valpeyfisher.com • RevA_1007