The UT54ACS138 and the UT54ACTS138 3-line to 8-line de-
coders/demultiplexers are designed to be used in high-perfor-
mance memory-decoding or data-routing applications requiring
very short propagation delay times.
The conditions at the binary select inputs and the three enable
inputs select one of eight output lines. Two active-low and one
active-high enable inputs reduce the need for external gates of
inverters when expanding. A 24-line decoder can be implement-
ed without external inverters and a 32-line decoder requires only
one inverter. An enable input can be used as a data input for
demultiplexing applications.
The devices are characterized over full military temperature
range of -55 C to +125 C.
FUNCTION TABLE
ENABLE INPUTS
G1
X
L
X
H
H
H
H
H
H
H
H
G2A
X
X
H
L
L
L
L
L
L
L
L
G2B
H
X
X
L
L
L
L
L
L
L
L
C
X
X
X
L
L
L
L
H
H
H
H
SELECT INPUTS
B
X
X
X
L
L
H
H
L
L
H
H
A
X
X
X
L
H
L
H
L
H
L
H
Y0
H
H
H
L
H
H
H
H
H
H
H
Y1
H
H
H
H
L
H
H
H
H
H
H
Y2
H
H
H
H
H
L
H
H
H
H
H
A
B
C
G2A
G2B
G1
Y7
V
SS
16-Lead Flatpack
Top View
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
V
DD
Y0
Y1
Y2
Y3
Y4
Y5
Y6
OUTPUT
Y3
H
H
H
H
H
H
L
H
H
H
H
Y4
H
H
H
H
H
H
H
L
H
H
H
Y5
H
H
H
H
H
H
H
H
L
H
H
Y6
H
H
H
H
H
H
H
H
H
L
H
Y7
H
H
H
H
H
H
H
H
H
H
L
71
RadHard MSI Logic
UT54ACS138/UT54ACTS138
LOGIC SYMBOL
(1)
BIN/OCT
1
2
4
0
1
2
3
4
G1
G2A
G2B
(6)
(4)
(5)
&
EN
5
6
7
(15)
(14)
(13)
(12)
(11)
(10)
(9)
(7)
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
G2B
G1
G2A
(6)
(4)
(5)
&
EN
A
B
C
(1)
(2)
(3)
DMUX
1
2
4
A
B (2)
(3)
C
0
G
---
7
0
1
2
3
4
5
6
7
(15)
(14)
(13)
(12)
(11)
(10)
(9)
(7)
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Note:
1. Logic symbols in accordance with ANSI/IEEE standard 91-1984 and IEC Publication 617-12.
LOGIC DIAGRAM
(15)
(14)
G1
ENABLE
(6)
(13)
(12)
(11)
(10)
Y0
Y1
Y2
Y3
DATA
Y4
Y5
Y6
Y7
G2A (4)
G2B (5)
A
SELECT
B
(1)
(2)
(9)
(7)
C (3)
RadHard MSI Logic
72
UT54ACS138/UT54ACTS138
RADIATION HARDNESS SPECIFICATIONS
1
PARAMETER
Total Dose
SEU Threshold
2
SEL Threshold
Neutron Fluence
LIMIT
1.0E6
80
120
1.0E14
UNITS
rads(Si)
MeV-cm
2
/mg
MeV-cm
2
/mg
n/cm
2
Notes:
1. Logic will not latchup during radiation exposure within the limits defined in the table.
2. Device storage elements are immune to SEU affects.
ABSOLUTE MAXIMUM RATINGS
SYMBOL
V
DD
V
I/O
T
STG
T
J
T
LS
JC
PARAMETER
Supply voltage
Voltage any pin
Storage Temperature range
Maximum junction temperature
Lead temperature (soldering 5 seconds)
Thermal resistance junction to case
DC input current
Maximum power dissipation
LIMIT
-0.3 to 7.0
-.3 to V
DD
+.3
-65 to +150
+175
+300
20
10
1
UNITS
V
V
C
C
C
C/W
mA
W
I
I
P
D
Note:
1. Stresses outside the listed absolute maximum ratings may cause permanent damage to the device. This is a stress rating only, functional operation of the device
at these or any other conditions beyond limits indicated in the operational sections is not recommended. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
SYMBOL
V
DD
V
IN
T
C
PARAMETER
Supply voltage
Input voltage any pin
Temperature range
LIMIT
4.5 to 5.5
0 to V
DD
-55 to + 125
UNITS
V
V
C
73
RadHard MSI Logic
UT54ACS138/UT54ACTS138
DC ELECTRICAL CHARACTERISTICS
7
(V
DD
= 5.0V 10%; V
SS
= 0V
6
, -55 C < T
C
< +125 C)
SYMBOL
V
IL
PARAMETER
Low-level input voltage
1
ACTS
ACS
High-level input voltage
1
ACTS
ACS
Input leakage current
ACTS/ACS
Low-level output voltage
3
ACTS
ACS
High-level output voltage
3
ACTS
ACS
Short-circuit output current
2 ,4
ACTS/ACS
Output current
10
(Sink)
I
OH
Output current
10
(Source)
P
total
I
DDQ
I
DDQ
Power dissipation
2, 8, 9
Quiescent Supply Current
Quiescent Supply Current Delta
ACTS
V
IN
= V
DD
or V
SS
I
OL
= 8.0mA
I
OL
= 100 A
I
OH
= -8.0mA
I
OH
= -100 A
V
O
= V
DD
and V
SS
V
IN
= V
DD
or V
SS
V
OL
= 0.4V
V
IN
= V
DD
or V
SS
V
OH
= V
DD
- 0.4V
C
L
= 50pF
V
DD
= 5.5V
For input under test
V
IN
= V
DD
- 2.1V
For all other inputs
V
IN
= V
DD
or V
SS
V
DD
= 5.5V
C
IN
C
OUT
Input capacitance
5
Output capacitance
5
= 1MHz @ 0V
= 1MHz @ 0V
15
15
pF
pF
1.9
10
1.6
mW/
MHz
A
mA
-8
mA
.7V
DD
V
DD
- 0.25
-200
8
200
.5V
DD
.7V
DD
-1
1
CONDITION
MIN
MAX
0.8
.3V
DD
UNIT
V
V
IH
V
I
IN
V
OL
A
0.40
0.25
V
V
OH
V
I
OS
I
OL
mA
mA
RadHard MSI Logic
74
UT54ACS138/UT54ACTS138
Notes:
1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: V
IH
= V
IH
(min) + 20%, - 0%; V
IL
= V
IL
(max) + 0%,
- 50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified range, but
are guaranteed to V
IH
(min) and V
IL
(max).
2. Supplied as a design limit but not guaranteed or tested.
3. Per MIL-PRF-38535, for current density 5.0E5 amps/cm
2
, the maximum product of load capacitance (per output buffer) times frequency should not exceed
3,765 pF/MHz.
4. Not more than one output may be shorted at a time for maximum duration of one second.
5. Capacitance measured for initial qualification and when design changes may affect the value. Capacitance is measured between the designated terminal and V
SS
at frequency of 1MHz and a signal amplitude of 50mV rms maximum.
6. Maximum allowable relative shift equals 50mV.
7. All specifications valid for radiation dose 1E6 rads(Si).
8. Power does not include power contribution of any TTL output sink current.
9. Power dissipation specified per switching output.