Optoway
FEATURES
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Hot-Pluggable SFP Footprint LC Optical Transceiver
Small Form-Factor Pluggable (SFP) MSA compatible
Compliant with IEEE 802.3z Gigabit Ethernet
Compliant with Fibre Channel 1X SM-LC-L FC-PI
SFF-8472 Digital Diagnostic Function
18 Wavelength (λ): 1270 nm to 1610 nm CWDM DFB
LD Transmitter
APD High Sensitivity Receiver
32 dB Power Budget at Least
AC/AC Coupling according to MSA
Single +3.3 V Power Supply
RoHS Compliant
0 to 70
o
C Operation: SPS-73120W-CXX0G
-5 to 85
o
C Operation: SPS-73120BW-CXX0G
-40 to 85
o
C Operation: SPS-73120AW-CXX0G
Class 1 Laser International Safety Standard IEC-60825
Compliant
SPS-73120W-CXX0G
1
***********************************************************************************************************************************************************************
SPS-73120W-CXX0G / SPS-73120BW-CXX0G / SPS-73120AW-CXX0G
(RoHS Compliant)
3.3V / CWDM / 1.25 Gbps
Digital Diagnostic
SFP LC SINGLE-MODE TRANSCEIVER
**********************************************************************************************************************************************************************
DESCRIPTION
The SPS-73120W-CXX0G series single mode transceivers
is small form factor pluggable module for bi-directional
serial optical data communications such as Gigabit Ethernet
and Fibre Channel 1x SM-LC-L FC-PI. It is with the SFP
20-pin connector to allow hot plug capability. Digital
diagnostic functions are available via an I
2
C. This module
is designed for single mode fiber and operates at a nominal
wavelength of CWDM wavelength. There are eighteen
center wavelengths available from 1270 nm to 1610 nm,
with each step 20 nm. A guaranteed minimum optical link
budget of 32 dB is offered The transmitter section uses a
multiple quantum well CWDM DFB laser and is a class 1
laser compliant according to International Safety Standard
IEC-60825. The receiver section uses an integrated InGaAs
Avalanche photodetector preamplifier mounted in an
optical header and a limiting post-amplifier IC.
LASER SAFETY
APPLICATIONS
l
l
l
l
Gigabit Ethernet Switches and Routers
Fibre Channel Switch Infrastructure
XDSL Applications
Metro Edge Switching
This single mode transceiver is a Class 1 laser product. It
complies with IEC-60825 and FDA 21 CFR 1040.10 and
1040.11. The transceiver must be operated within the
specified temperature and voltage limits. The optical ports
of the module shall be terminated with an optical connector
or with a dust plug.
ORDER INFORMATION
P/No.
Bit Rate
(Gb/s)
1.25
1.25
1.25
Typ.
(nm)
1270
1290
1310
1330
1350
1370
1390
1410
1430
1000
BASE
Power Wavelength
Package
Temp. TX Power RX Sens. RoHS
Budget
(nm)
(
o
C)
(dBm)
(dBm) Compliant
(dB)
> 32
CWDM*
LC SFP with DMI
0 to 70
5 to 0
-32
Yes
> 32
CWDM*
LC SFP with DMI
-5 to 85
5 to 0
-32
Yes
> 32
CWDM*
LC SFP with DMI
-40 to 85
5 to 0
-32
Yes
Clasp Color
Central
Code
Wavelength
Light Purple
-C450
Sky Blue
-C470
Yellow Green
-C490
Yellow Ocher
-C510
Pink
-C530
Beige
-C550
White
-C570
Silver
-C590
Black
-C610
Min.
(nm)
1444.5
1464.5
1484.5
1504.5
1524.5
1544.5
1564.5
1584.5
1604.5
Typ.
(nm)
1450
1470
1490
1510
1530
1550
1570
1590
1610
Max.
(nm)
1457.5
1477.5
1497.5
1517.5
1537.5
1557.5
1577.5
1597.5
1617.5
Clasp Color
Code
Yellow Orange
Gray
Violet
Blue
Green
Yellow
Orange
Red
Brown
SPS-73120W-CXX0G
SPS-73120BW-CXX0G
SPS-73120AW-CXX0G
Central
Wavelength
-C270
-C290
-C310
-C330
-C350
-C370
-C390
-C410
-C430
Min.
(nm)
1264.5
1284.5
1304.5
1324.5
1344.5
1364.5
1384.5
1404.5
1424.5
CWDM* Wavelength (0 to 70
o
C)
Max.
(nm)
1277.5
1297.5
1317.5
1337.5
1357.5
1377.5
1397.5
1417.5
1437.5
CWDM*: 18 Wavelengths from 1270 nm to 1610 nm, each step 20 nm.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: sales@optoway.com.tw
Fax: 886-3-5979737
http: // www.optoway.com.tw
1/1/2009 V4.0
Optoway
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Case Temperature
Symbol
Tstg
Topr
Min
-40
0
-5
-40
-0.5
Max
85
70
85
85
3.6
Units
o
C
o
C
SPS-73120W-CXX0G
Notes
SPS-73120W-CXX0G
SPS-73120BW-CXX0G
SPS-73120AW-CXX0G
2
***********************************************************************************************************************************************************************
Power Supply Voltage
Vcc
V
Recommended Operating Conditions
Parameter
Power Supply Voltage
Operating Case Temperature
Symbol
Vcc
Topr
Min
3.13
0
-5
-40
100
Typ
3.3
Max
3.47
70
85
85
350
Units / Notes
V
o
C / SPS-73120W-CXX0G
o
C / SPS-73120BW-CXX0G
o
C / SPS-73120AW-CXX0G
mA
Mb/s
Power Supply Current
Data Rate
I
CC (TX+RX)
230
1250
Transmitter Specifications (0
o
C < Topr < 70
o
C, 3.13V < Vcc < 3.47V)
Parameter
Optical
Optical Transmit Power
Output Center Wavelength
Output Spectrum Width
Side Mode Suppression Ratio
Extinction Ratio
Optical Rise Time
Optical Fall Time
Relative Intensity Noise
Electrical
Data Input Current
–
Low
Data Input Current
–
High
Differential Input Voltage
TX Disable Input Voltage
–
Low
TX Disable Input Voltage
–
High
TX Disable Assert Time
TX Disable Deassert Time
TX Fault Output Voltage -- Low
TX Fault Output Voltage -- High
Symbol
Po
λ
∆λ
SMSR
E
R
t
r
t
f
RIN
I
IL
I
IH
V
IH
- V
IL
T
DIS, L
T
DIS, H
T
ASSERT
T
DEASSERT
T
FaultL
T
FaultH
Min
0
λc
–5.5
---
30
9
Typ
---
λc
---
---
Max
5
λc
+7.5
1
---
260
260
-120
Units
dBm
nm
nm
dB
dB
ps
ps
dB/Hz
µA
µA
V
V
V
µs
ms
V
V
Notes
1
2
-20 dB Width
20 % to 80% Values
20 % to 80% Values
-350
0.5
0
2.0
350
2.4
0.5
Vcc
10
1
0.5
Vcc+0.3
Peak-to-Peak
3
3
0
2.0
4
4
1. Output power is power coupled into a 9/125
µm
single mode fiber.
2. ITU-T G.694.2 CWDM wavelength from 1270 nm to 1610 nm, each step 20 nm.
3. There is an internal 4.7K to 10K ohm pull-up resistor to VccTX.
4. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage).
Receiver Specifications (0
o
C < Topr < 70
o
C, 3.13V < Vcc < 3.47V)
Parameter
Optical
Sensitivity
Maximum Input Power
Signal Detect -- Asserted
Signal Detect -- Deasserted
Signal detect -- Hysteresis
Symbol
Sens
Pin
Pa
Pd
Min
Typ
Max
-32
-9
---
-45
1.0
-32
---
Units
dBm
dBm
dBm
dBm
dB
Notes
4
4
Transition: low to high
Transition: high to low
---
---
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: sales@optoway.com.tw
Fax: 886-3-5979737
http: // www.optoway.com.tw
1/1/2009 V4.0
Optoway
Wavelength of Operation
Electrical
Differential Output Voltage
Output LOS Voltage -- Low
Output LOS Voltage -- High
1100
V
OH
–
V
OL
V
OL
V
OH
0.6
0
2.0
---
1620
2.0
0.5
Vcc+0.3
nm
V
V
V
SPS-73120W-CXX0G
3
***********************************************************************************************************************************************************************
5
5
4. Measured at 2
7
-1 PRBS at BER 1E-12.
5. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage).
CONNECTION DIAGRAM
PIN
1
2
3
4
5
6
7
8
9
10
Signal Name
TX GND
TX Fault
TX Disable
MOD-DFE2
MOD-DEF1
MOD-DEF0
N/C
LOS
RX GND
RX GND
Description
Transmitter Ground
Transmitter Fault Indication
Transmitter Disable (Module disables
on high or open)
Modulation Definition 2
–
Two wires
serial ID Interface
Modulation Definition 1
–
Two wires
serial ID Interface
Modulation Definition 0
–
Ground in
Module
Not Connected
Loss of Signal
Receiver Ground
Receiver Ground
PIN
11
12
13
14
15
16
17
18
19
20
Signal Name
Description
RX GND
Receiver Ground
RX DATA OUT- Inverse Receiver Data Out
RX DATA OUT+ Receiver Data Out
RX GND
Vcc RX
Vcc TX
TX GND
TX DATA IN+
TX DATA IN-
TX GND
Receiver Ground
Receiver Power
–
3.3V±5%
Transmitter Power
–
3.3V±5%
Transmitter Ground
Transmitter Data In
Inverse Transmitter Data In
Transmitter Ground
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: sales@optoway.com.tw
Fax: 886-3-5979737
http: // www.optoway.com.tw
1/1/2009 V4.0
Optoway
MODULE DEFINITION
Module Definition
4
MOD-DEF2
PIN 4
SDA
MOD-DEF1
PIN 5
SCL
MOD-DEF0
PIN 6
LV-TTL Low
SPS-73120W-CXX0G
Interpretation by Host
Serial module definition
protocol
4
***********************************************************************************************************************************************************************
Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, MOD-DEF(1:2) appear as no connector
(NC) and MOD-DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the
2-wire serial CMOS E
2
PROM protocol of the ATMEL AT24C01A/02/04 family of components.
RECOMMENDED CIRCUIT SCHEMATIC
VeeT
Tx_DISABLE
Tx_FAULT
(1,17,20)
3
2
4.7K to 10KΩ
TD +
18
Z=50Ω
TD -
19
Z=50Ω
VccT
16
10nF
1μH
Vcc 3.3V
10μF
10nF
1μH
VccR
15
10nF
10μF
10μF
TD -
TD +
Tx_DISABLE
Tx_FAULT
LD
Driver
100Ω
SerDes
IC
Protocol
IC
RD -
12
Z=50Ω
100Ω
RD -
POST
Amp
RD +
13
Z=50Ω
4.7K to 10KΩ
RD +
depending on SERDES
LOSS OF SINGAL
LOS
VeeR
MOD_DEF(0)
8
(9,10,11,14)
6
5
4
4.7K to 10KΩ
Vcc 3.3V
4.7K to 10KΩ
MODULE DETECT
SCL
SDA
4.7K to 10KΩ
EEPROM
MOD_DEF(1)
MOD_DEF(2)
SFP module
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: sales@optoway.com.tw
Fax: 886-3-5979737
http: // www.optoway.com.tw
1/1/2009 V4.0
Optoway
PACKAGE DIAGRAM
Units in mm
SPS-73120W-CXX0G
5
***********************************************************************************************************************************************************************
Note: Specifications subject to change without notice.
REVISION HISTORY
Version
1.0
2.0
3.0
4.0
Subject
Initial datasheet
Add 1270 to 1450 nm CWDM.
1. Revise package diagram for high port density use
2. Add clasp color codes for 18 wavelengths
Add -40 to 85
o
C SPS-73120W-CXX0G
Release Date
2004/1/1
2005/12/1
2008/1/1
2009/1/1
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: sales@optoway.com.tw
Fax: 886-3-5979737
http: // www.optoway.com.tw
1/1/2009 V4.0