UNI-PAC™ 2C
Low Cost Power Inductors
(Surface Mount)
Description
• Miniature surface mount design with rugged case to
eliminate core breakage
• Inductance range from 0.470uH to 1000uH
• Current range up to 18.6 Amps peak
• Meets UL94V-0 flammability standard
• RoHS compliant (-R option)
Applications
• PDA, computer, and flash memory programs
Environmental Data
• Storage temperature range: -40C to +125C
• Operating ambient temperature range: -40C to +85C
(range is application specific)
• Infrared reflow temperature: +240C for 30 seconds max.
Part
Number
UP2C-R47
UP2C-1R0
UP2C-1R5
UP2C-2R2
UP2C-3R3
UP2C-4R7
UP2C-6R8
UP2C-100
UP2C-150
UP2C-220
UP2C-330
UP2C-470
UP2C-680
UP2C-101
UP2C-151
UP2C-221
UP2C-331
UP2C-471
UP2C-681
UP2C-102
Inductance
µH
(rated)
0.470
1.0
1.5
2.2
3.3
4.7
6.8
10.0
15.0
22.0
33.0
47.0
68.0
100.0
150.0
220.0
330.0
470.0
680.0
1000.0
OCL
(1)
µH±20%
0.48
1.03
1.45
2.00
3.30
4.41
7.16
10.56
15.97
22.33
32.11
47.90
65.03
97.85
141.9
207.8
318.2
470.8
689.7
1080.0
I
RMS
(2)
Amperes
12.2
9.80
8.10
7.50
5.90
5.62
4.42
3.61
3.17
2.61
2.16
1.77
1.57
1.26
1.04
0.82
0.67
0.56
0.46
0.38
Packaging
• Supplied in tape and reel packaging, 900 per reel
I
SAT
(3)
Amperes
18.6
11.8
10.0
8.67
6.84
6.20
4.82
3.94
3.17
2.65
2.20
1.83
1.53
1.24
1.02
0.85
0.70
0.58
0.48
0.40
DCR
(4)
mΩ
typ.
2.5
3.9
5.6
6.6
10.5
11.7
18.0
28.3
36.9
54.0
79.7
118.5
151.7
233.1
351.4
545.0
824.3
1191.4
1774.2
2657.1
Volts
(5)
µS
(typ)
4.15
7.0
8.3
9.6
12.1
13.4
17.3
21.1
26.2
31.3
37.7
45.4
54.3
67.1
81.2
97.8
120
144
173
209
Notes:
(1) Open Circuit Inductance Test Parameters: 100KHz, .250Vrms, 0.0Adc.
(2) RMS current for an approximate
∆T
of 40°C without core loss, at an
ambient temperature of 85˚C.
(3) Peak current for approximately 30% rolloff @ 20°C.
(4) DCR limits 20°C.
(5) Applied volt-time product (V-uS) across the inductor. This value
represents the applied v-us at 300KHz necessary to generate a core
loss equal to 10% of the total losses for a 40° temperature rise.
Option Code
-R
OPTION CODE
Description
RoHS compliant version
Mechanical Diagrams
TOP VIEW
12.90
Max.
FRONT VIEW
5.2
PCB PAD LAYOUT
7.37
SCHEMATIC
1
SIDE VIEW
UP2C
xxx
wwllyy R
3.0ref
9.40
Max.
2
2.79
2.92
1
2.5max*
see note A
COMPONENT VIEW
2
Dimensions in Millimeters.
wwllyy = (date code) R = revision level
xxx = Inductance value per family chart
(A) 2.5mm max is width of copper at seating plane. The width above the seating
plane may exceed 2.5mm.
®
UNI-PAC™ 2C
Low Cost Power Inductors
(Surface Mount)
Packaging Information
4.0
1.5 dia
+0.1/-0.0
2.0
1.5 dia
min
A
1.7
1
11.5
24.0
+/-0.3
B0
ACTUAL SIZE
UNIPAC 2C
2
Ao=9.50mm
Bo=13.0mm
Ko=5.7mm
K0
SECTION A-A
A0
12.0
User direction of feed
A
Typical Inductance &
Energy vs. Saturation
Current
Core Loss
I
RMS
DERATING WITH CORE LOSS
0
% of Losses from Irms (maximum)
20
40
50
60
70
80
0K
Hz
Hz
Hz
0K
20
1M
50
30
90
92
94
95
96
97
98
99
10
20
30
40
50
60
80
100
200
300
400 500 600
800 1000
% of Applied Volt-µ-Seconds
PM-4111 7/05
© Cooper Electronic
Technologies 2005
Visit us on the Web at www.cooperET.com
3601 Quantum Boulevard Boynton Beach, Florida 33426-8638
Tel: +1-561-752-5000 Toll Free: +1-888-414-2645 Fax: +1-561-742-1178
This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Electronic
Technologies reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper
Electronic Technologies also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been
selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Electronic Technologies does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when
properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.
10
0K
Hz
Hz
0K