EEWORLDEEWORLDEEWORLD

Part Number

Search

H6067ALBR3

Description
Rocker Switch, DPDT, On-on, Latched, Quick Connect Terminal, Softline Matt Type Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size235KB,2 Pages
ManufacturerArcolectric
Environmental Compliance
Download Datasheet Parametric View All

H6067ALBR3 Overview

Rocker Switch, DPDT, On-on, Latched, Quick Connect Terminal, Softline Matt Type Actuator, Panel Mount, ROHS COMPLIANT

H6067ALBR3 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerArcolectric
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator colorRED
Actuator length0.315 inch
Actuator typeSOFTLINE MATT TYPE
body width25 mm
body height30 mm
Body length or diameter31.5 mm
center contact materialSILVER ALLOY
Contact (AC) maximum rated R load20A@277VAC
Maximum contact current (AC)20 A
Contact functionON-ON
Contact resistance0.1 mΩ
Maximum contact voltage (AC)277 V
Dielectric withstand voltage3000VAC V
Electrical life10000 Cycle(s)
End contact materialSILVER ALLOY
illuminationLAMP
Insulation resistance20000000 Ω
insulator materialNYLON
Manufacturer's serial number6050
Installation featuresPANEL MOUNT
sealIP44
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typeROCKER SWITCH
Terminal length0.382 inch
Termination typeQUICK CONNECT
6050 DP Splashproof Switches - & Twins
Water thru design
Ratings up to 20A,
277V ac
High in-rush (ON-OFF
types)
Positive switch action
Distinctive styling
Illuminated & non-
illuminated
Double pole
Bezel size:
31.5 x 25mm
In house test
#
16A 250Vac
European 16(4)A 250Vac T125, 10A 400Vac T125
UL CSA 20A 277Vac, 250Vac 1
1
/
2
hp, 125Vac 1hp
UL 100˚C, file E45221, CSA file LR10990
Inrush 150A* to EN61058-1
8(8)A 250Vac T125 5E4 on 6050 only
*
applies to non-momentary types
RoHS compliant
RoHS
3mm contact gap with Positive Break switching.
# Call factory for IP details on Twin units.
Technical data on pages 4 & 5 (switches), 66 (indicators).
Patent app.
B
BLACK
R
RED
W
WHITE
NON-LIT
B
BLACK
R
RED
W
WHITE
A
C
G
R
LIT
AMBER
CLEAR
GREEN
RED
2
125V NEON
3
250V NEON
7
12V INCANDESCENT
C 6053 A L B R 2 1197W
ORDER FORMAT
TERMINAL
C
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminals 3 & 6
9.7
1
4
2
5
3
6
TERMINAL
CODE
FUNCTION
CODE
FUNCTION
ROCKER
CODE
BODY BODY
CODE COLOR
ROCKER
COLOR
LAMP VOLTAGE
IF REQUIRED
ROCKER
A
Softline
Matt
LEGEND &
OPTIONS
6.3 x 0.8
6050
6051
ON - OFF
6060
6061
ON - ON
ON - OFF
(momentary ON)
ON - OFF
(momentary OFF)
ON - OFF
Lit
ON - OFF
(momentary ON)
Lit
ON - OFF (Single pole)
(momentary ON)
Lit
ON - OFF (Single pole)
Isolated light
ON - OFF
Isolated light
ON - OFF (Single pole)
Lit
ON - OFF (Single pole)
(momentary ON
Isolated light)
ON - ON
(momentary 1 side)
6052
H
6053
9.7
6062
2 Circuit ON - ON
A
Softline
Matt
In house tests only
6066
ON - ON (Single pole)
(isolated light)
ON - ON
Lit
ON - ON 1pole
ON - OFF Lit 1pole
ON - OFF 1pole
ON - OFF Lit 1pole
ON - OFF
(momentary ON)
Lit
ON - OFF 1 pole
ON - ON 1 pole
Lit
Circuits are Double Pole
unless described otherwise
Lit Window
Lit
6054
4.8 x 0.8
6067
6055
6068
P
Lit Window
Matt
6056
6090
S
9.7
6057
6091
6058
6092
Screw & Clamp
N/A for assemblies
with 3 terminals in either pole
6059
18
ARCOLECTRIC CORPORATION
31-315 Plantation Drive, Thousand Palms, CA 92276 Tel: 760-343-3650 Fax: 760-343-3651 email: info@arcolectric.com
Supercapacitors: Materials, Systems and Applications
Supercapacitors are a new type of energy storage device between electrolytic capacitors and batteries. They have the characteristics of long cycle life and large current charge and discharge. They hav...
arui1999 Download Centre
Skills required by MCU engineers and embedded engineers
1. Job analysis of single-chip microcomputer1. Hardware directiona. Familiar with the design and application of analog circuits and digital circuits;b. Have experience in project schematic PCB design ...
cdhqyj Programming Basics
MSP430 clock system problem
[size=4] The clock problem of MSP430 has always been vague, and I always forget it, so I decided to write this article to help me remember. The following content is all referenced to online materials ...
灞波儿奔 Microcontroller MCU
The more "flirty" serpentine traces on a PCB, the more "advanced" it is?
The serpentine line is a routing method often used in the PCB wiring process. Its main purpose is to adjust the delay and meet the system timing design requirements. However, every PCB design engineer...
mwkjhl PCB Design
Happy Dragon Boat Festival
...
dcexpert Talking
Static electricity
The company has made a car side turn signal light, the circuit is very simple, now when the power is off, the ground of the static gun is connected to the product input ground, when 4KV static electri...
aq1261101415 Automotive Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号