Low Voltage Supplementary Fuses
13
⁄
32
” x 1
1
⁄
2
” Fast-acting fuses
BAN
KTK & KLM
Specifications
Class:
Supplemental
Description:
Fast-
acting supplementary
fuse.
Dimensions:
13
⁄
32
” x
1
1
⁄
2
(10.3 x 38.1mm).
Construction:
Melamine tube; nickel
plated brass endcaps.
Ratings:
Volts — KTK: 600Vac (or less)
— KLM: 500Vac/600Vdc (
1
⁄
10
A to
1
⁄
8
A)
— 500Vac/dc (
2
⁄
10
-10A)
— 500Vac/600Vdc (12-30A)
Amps —
1
⁄
10
-30A
IR — KTK: 100,000A RMS Sym. (UL)
— KLM: 10,000A RMS Sym. (UL)
Agency Information:
CE, Std. 248-14,
KTK-UL Listed, Guide JDYX, File E19180,
KLM-UL Recognized, Guide JFHR2, File
E56412, CSA Certified, File 53787, Class
1422-01, HRC-Misc.
Features and Benefits
• Low cost supplemental protection of 600V
or less non-inductive circuits.
• Upgrade with LP-CC product to reduce
SKU investment and minimize potential
arc-flash hazards.
Typical Applications
• Control Circuits
• Lighting Circuit Protection
• Meter Circuits
Catalog Numbers (Amps)
600Vac - UL Listed and CSA
KTK-
1
⁄
10
KTK-
3
⁄
4
KTK-1
KTK-1 ⁄
4
1
BAF
Specifications
Specifications
Class:
Supplemental
Class:
Supplemental
Description:
Fast-acting
Description:
Fast-acting
supplementary fuse.
supplementary fuse.
Dimensions:
13
⁄
32
” x 1
1
⁄
2
Dimensions:
13
⁄
32
” x 1
1
⁄
2
(10.3 x 38.1mm).
(10.3 x 38.1mm).
Construction:
Fibre
Construction:
Fibre tube.
cartridge; nickel plated
Ratings:
brass endcaps.
Volts — 250Vac
Ratings:
Amps — 1-30A
Volts — 250Vac (
2
⁄
10
-15A)
IR — 35A (1.1-3.5A)
— 125Vac (20-30A)
— 100A (3.6-10A)
Amps — 1-6A
— 200A (10.1-15A)
IR — 10,000A @ 125Vac (
2
⁄
10
-30A)
— 750A (15.1-30A)
— 35A (
2
⁄
10
-1A @ 250Vac)
Features and Benefits
— 100A (1
1
⁄
2
-6A @ 250Vac)
• Low cost supplemental protection of
— 200A (6
1
⁄
4
-10A @ 250Vac)
125V and 250V non-inductive
— 750A (12A- 15A @ 250Vac)
circuits.
Agency Information:
CE, Std. 248-14, • Upgrade with LP-CC product to
UL 0-15/250V, Guide JDYX, File E19180
reduce SKU investment and mini-
CSA Certified, 0-15/250V, Class
mize potential arc-flash hazards.
1422-01, File 53787.
(and
minimize potential for misapplying
Features and Benefits
fuse.)
• Low cost supplemental protection of
125V and 250V non-inductive circuits.
Typical Applications
• Upgrade with LP-CC product to reduce • General Purpose Circuits
SKU investment and minimize potential • Lighting Circuit Protection
arc-flash hazards. (and minimize
• Meter Circuits
potential for misapplying fuse.)
Catalog Numbers (Amps)
Typical Applications
BAN-1
BAN-5
BAN-12
BAN-30
• General Purpose Circuits
BAN-2
BAN-6
BAN-15
• Lighting Circuit Protection
BAN-3
BAN-8
BAN-20
• Meter Circuits
BAN-4
BAN-10
BAN-25
Low Voltage
Supplementary
Fuses
KTK-4
KTK-5
KTK-6
KTK-7
KTK-7 ⁄
2
1
1
KTK-12
KTK-15
KTK-20
KTK-25
KTK-30
KTK-35
KTK-40
KTK-45
KTK-50
Catalog Numbers (Amps)
BAF-
2
⁄
10
BAF-
1
⁄
4
BAF-
1
⁄
2
BAF-
6
⁄
10
BAF-
8
⁄
10
BAF-1
BAF-1 ⁄
2
1
Recommended Fuse blocks ⁄
10
to 30A
Catalog Numbers
Terminal Type
Screw with
Quick Connect
BM6031SQ
BM6032SQ
BM6033SQ
Pressure Plate w/
Quick Connect
Box Lug
BM6031PQ
BM6032PQ
BM6033PQ
BM6031B
BM6032B
BM6033B
Poles
1
2
3
1
KTK- ⁄
8
1
BAF-2
BAF-2
1
⁄
2
BAF-3
BAF-4
BAF-5
BAF-6
BAF-6 ⁄
4
1
BAF-8
BAF-9
BAF-10
BAF-12
BAF-15
BAF-20
BAF-25
BAF-30
KTK- ⁄
10
2
KTK-
1
⁄
4
KTK- ⁄
10
3
KTK-1
1
⁄
2
KTK-2
KTK-2 ⁄
2
KTK-3
KTK-3 ⁄
2
1
KTK- ⁄
10
4
KTK-8
KTK-9
KTK-10
KTK- ⁄
2
1
KTK- ⁄
10
6
BAF-1
8
⁄
10
BAF-7
*500Vac/dc - UL Recognized and CSA.
KLM-
1
⁄
10
KLM-
3
⁄
4
KLM-1
KLM-1
1
⁄
2
KLM-2
KLM-3
KLM-4
1
1
*All have interrupting rating of 10,000A at 125V.
KLM-5
KLM-6
KLM-8
KLM-10
KLM-12
KLM-15
KLM-20
KLM-25
KLM-30
Data Sheet: 2011 (0-30)
KLM- ⁄
8
1
Data Sheet: 2046 (0-30)
KLM-
2
⁄
10
KLM-
1
⁄
4
KLM- ⁄
10
3
For superior electrical protection, Cooper Bussmann recommends upgrading BAF,
BAN and KTK fuse applications to Low-Peak LP-CC fuses See page 19.
Recommended fuse blocks/fuse holders for
13
⁄
32
” x 1
1
⁄
2
” fuses
KLM- ⁄
2
1
*KLM-( ⁄
10
- ⁄
8
A & 12-30A): 500Vac/600Vdc.
• See page 40
Data Sheets: KTK-1011 KLM-2020
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
43