ELECTRIC FUSE, 2A, 600VAC, 250A (IR), SURFACE MOUNT, ROHS COMPLIANT
FT600-2000-2 Parametric
Parameter Name
Attribute value
Is it Rohs certified?
conform to
Maker
TE Connectivity
package instruction
ROHS COMPLIANT
Reach Compliance Code
compliant
ECCN code
EAR99
body width
3.4 mm
body height
10.5 mm
Body length or diameter
3.4 mm
Circuit protection type
ELECTRIC FUSE
Joule integral nominal
18 J
Manufacturer's serial number
FT600
Installation features
SURFACE MOUNT
method of packing
TAPE AND REEL
physical size
3.4mm x 3.4mm x 10.5mm
Rated breaking capacity
250 A
Rated current
2 A
Rated voltage (AC)
600 V
Guideline
CSA; UL
surface mount
YES
Terminal shape
WRAPAROUND
FT600-2000-2 Preview
Raychem FT600 Series Overcurrent Fuse
New surface-mount fuse products for overcurrent protection of communications equipment
Benefits:
• When combined with a SiBar™ overvolt-
age protection device, assists equipment
in meeting regulatory standards with no
additional series components
• Improved temperature rise performance
over other similar SMT fuse devices
under sneak current testing
• High density placement in multi-port
system designs
Features:
• The lightning robust surface-mount fuse
offers overcurrent protection from power
faults
• Designed to assist equipment in comply-
ing with telecom specifications including
UL60950, FCC Part 68, and Telcordia
GR-1089
• Small footprint and low resistance
• Low profile
Target Applications:
• xDSL and ADSL linecards and modems
• T1/E1 systems
• Twisted pair telecom ports requiring
Telcordia GR-1089, UL60950 and FCC
Part 68 compliance
Interrupt Voltage and Current Ratings
Part
Number
FT600-0500
FT600-1250
FT600-2000
Ampere Rating
(A)
0.50
1.25
2.00
Voltage Rating
(V)
250
250
250
Typical Resistance
(Ω)
0.5
0.1
0.05
Typical I
2
t
(A
2
s)*
1
16
18
The FTxxxx devices are designed to carry 100% of rated current for 4 hours minimum and 250% of rated current for 1 second minimum, 120 seconds maximum. Resistance measured at 10% of rated current.
*I
2
t is calculated at 10 ms or less.
Power Cross
GR-1089
1000Vac, 5A, 0.5sec
FT600-0500
FT600-1250
FT600-2000
✓
✓
GR-1089
600Vac, 60A, 5sec
✓
✓
UL60950
600Vac, 40A, 1.5sec
✓
✓
✓
GR-1089/UL60950
600Vac, 7A, 5sec
✓
✓
✓
GR-1089/UL60950
600Vac, 2.2A, 30min
✓
✓
✓
GR-1089
277Vac, 25A, 15min
✓
✓
✓
UL60950
120Vac, 25A, 30min
✓
✓
✓
Note: FT600-1250 and FT600-2000 are designed to assist equipment in complying with Telcordia GR-1089 specifications. In-circuit testing is strongly recommended.
Lightning Surge
Telcordia
GR-1089
Surge Voltage (Vpk)
Wave Form (µs)
Surge Current (A)
Repetitions (each polarity)
FT600-0500
FT600-1250
FT600-2000
FCC
Part 68
Surge Voltage (Vpk)
Short Circuit Wave Form (µs)
Surge Current (A)
Repetitions (each polarity)
FT600-0500
FT600-1250
FT600-2000
First Level
Test 1
600
10x1000
100
25
✓
✓
Type A
Metallic
800
10x560
100
1
Fuse open
✓
✓
First Level
Test 2
1000
10x360
100
25
✓
✓
First Level
Test 3
1000
10x1000
100
25
✓
✓
Type A
Longitudinal
1500
10x160
200
1
Fuse open
✓
✓
First Level
Test 4
2500
2x10
500
10
✓
✓
Type B
Metallic
1000
5x320
25
1
✓
✓
✓
First Level
Test 5
1000
10x360
25
5
✓
✓
Second Level
Test 1
5000
2x10
500
1
✓
✓
Type B
Longitudinal
1500
5x320
37.5
1
✓
✓
✓
The FT600-0500, FT600-1250 and FT600-2000 are designed to meet the FCC Part 68 lightning surge requirements. Note that Type A tests allow for an overcurrent protection component to fuse open during
the surge.
Product Dimensions
A
B
C
Dimensions in millimeters (inches)
A (Max.)
10.5 (0.413)
B (Max.)
3.4 (0.133)
C (Max.)
3.4 (0.133)
Termination material
Body material
Termination solderability
Solder heat withstand
Solvent resistance
Storage temperature
Storage humidity
Details
Silver-plated brass
Ceramic
Per IEC-60127-4
Per MIL-STD-202, Method 210, Test Condition J
Per MIL-STD-202F, Method 215J
-40/+85°C
Per MIL-STD-202F, Method 106F
FT600 Series Fuses
Typical Time-to-Open Characteristics (at 25˚ C)
Thermal Derating Curve
130
120
PERCENT OF CURRENT RATING
110
100
90
80
70
-70
-50
-30
-10
10
30
50
70
90
110
130
AMBIENT TEMPERATURE (°C)
Solder Reflow Recommendations
300
Preheating
Soldering
Cooling
250
Temperature (°C)
Temperature (°C)
200
Solder Reflow
• Recommended reflow methods: IR, vapor phase oven, hot air oven.
• Devices can be cleaned using standard industry methods and
solvents.
Ordering Information
Part numbers
FT600-0500-2
FT600-1250-2
FT600-2000-2
2,500/reel
10,000/box
150
Devices per reel
Standard package
100
Note: The -2 designates tape and reel, the package
style for this product.
50
0
30 to 90
10 to 20
Time(s)
Time(s)
120
Recommended Pad Layout
The dimensions in the table below provide the recommended pad layout for each FT600 device.
SiBar is a trademark of Tyco Electronics Corporation.
All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco
Electronics makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics’ only obligations are
those in the Company’s Standard Terms and Conditions of Sale for this product, and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential
damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Electronics reserves the right
to make changes-without notification to Buyer-to materials or processing that do not affect compliance with any applicable specification.
Radio frequency identification (RFID) technology is a contactless automatic identification technology. Its basic principle is to use radio frequency signals and their spatial coupling and transmission...
Most modern PCs no longer have physical COM ports. However, many hardware setups still use UART for logging, diagnostics, and application control. The alternative is to use a USB device that appears a...
/***************************************************************************IAR environment, HD7279A, P4.0~CS, P4.1~CLK, P4.2~DATA, P4,3~KAY,DATA is the serial port data port, the timing diagram is as...
[i=s]This post was last edited by littleshrimp on 2021-10-2 14:15[/i]Finally IAR 9.10.2 is downloaded, and I can finally download the BLE_AT_Client example. The download and run speed is still very fa...
I see many friends searching on Baidu for how many channels of HD video codecs TX1 supports. To know how many channels of HD video codecs TX1 supports, you mainly need to look at the resolution and th...
Application Examples of Radio Signal Monitoring Using Portable Spectrum Analyzers Portable spectrum analyzers have become a common choice for radio interference detection and analysis, especially for...[Details]
As an important metal resource, cobalt plays a key role in the new energy field, especially in the manufacture of electric vehicle batteries. High-performance lithium-ion batteries are one of the c...[Details]
On May 7, the Linux 6.10 kernel plans to abandon support for DEC Alpha processors (EV5 and earlier versions), and also plans to abandon support for PowerPC 40x (early PowerPC 400 series) processors...[Details]
With the intelligent upgrading of the automobile industry and the popularization of autonomous driving, high-computing artificial intelligence chips with higher technological content, greater industr...[Details]
Humanoids create themselves
The video was released at Tesla's Investor Day event, and the robot in the video seems to be making another robot, "making itself". Could this be the Tesla humanoid...[Details]
The U.S. Air Force recently deployed a robot dog during its first-ever Simultaneous Nuclear Readiness Training (SNORT) at MacDill Air Force Base in Florida.
The so-called robot dog is actually...[Details]
Abstract: The networked terminal equipment introduced in this article combines the cellular network mobile communication terminal and the C-V2X PC5 direct communication terminal. The two exchange in...[Details]
lzb glass rotor flowmeter installation 1. First of all, check whether its technical parameters such as: measuring range, temperature grade, rated working pressure, temperature and other parameter...[Details]
Three elements of synchronous generator grid connection
The three elements of synchronous generator grid connection include:
1. Phase voltage: The synchronous generator must be able to ou...[Details]
Author profile: Zhang Jin (1994-), male, from Taiyuan, Shanxi, master student at Hunan University of Technology, main research direction is power battery simulation. E-mail: 1498641264@qq.com. 0 Pr...[Details]
The multifunctional conductivity tester circuit consists of a detection electrode, a resistor divider, a buffer circuit and a two-color diode, as shown in the figure. The detection electrode can s...[Details]
Today, let us walk into the production workshop of CATL and see how this battery cell, which is being fought over by Volkswagen, BMW and Mercedes-Benz, is manufactured.
A battery cell is...[Details]
The most common problems when measuring 220V mains electricity with an oscilloscope: 1. Tripping during measurement; 2. People accidentally get electric shock; 3. The oscilloscope burned during measu...[Details]
The core industrial chain of smart cars will be a battleground in the era of smart cars 2.0.
Since the beginning of this year, China's automobile industry has continued to advance rapi...[Details]
The "domino effect" caused by the shortage of 8-inch wafer foundry capacity and price increases is spreading to the entire industry: design manufacturers cannot wait for capacity or face the risk of ...[Details]