AC-DC Regulated Power Supply Module, 1 Output, 150W, METAL, CASE K02, MODULE
CategoryPower/power management    The power supply circuit   
File Size640KB,27 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LK1001-9EPV2TB1 Overview

AC-DC Regulated Power Supply Module, 1 Output, 150W, METAL, CASE K02, MODULE

LK1001-9EPV2TB1 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresIT ALSO OPERATES WITH 85 VAC TO 264 VAC INPUT VOLTAGE
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage372 V
Minimum input voltage88 V
Nominal input voltage310 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Maximum load regulation0.392%
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage5.13 V
Minimum output voltage5.07 V
Nominal output voltage5.1 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputNO
K-Family
DC-DC Converters >100 W
Rugged Environment
150 W DC-DC (AC-DC) Converters
Input to output isolation
Single output: AK...LK 1000
Double output: AK...LK 2000
Extremely wide input voltage range
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
4 kV
rms
input to output isolation test voltage
Fully isolated outputs
Outputs open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC 950
V
DE
C
K-Family
Table of Contents
Page
8.1
Description .................................................................. 8 - 2
Type Survey ................................................................ 8 - 3
Safety and Installation Instructions ............................. 8 - 4
Functional Description ................................................. 8 - 6
Electrical Input Data .................................................... 8 - 7
Electromagnetic Compatibility EMC ............................ 8 - 9
Electrical Output Data ............................................... 8 - 11
Supplementary Data ................................................. 8 - 19
Description of Options ............................................... 8 - 19
Immunity to Environmental Conditions ...................... 8 - 26
Mechanical Data ....................................................... 8 - 27
Type Key and Product Marking ................................. 8 - 28
Description
The K-family of DC-DC (AC-DC) converters represents a
broad and flexible range of power supplies for use in ad-
vanced electronic systems. Features include high effi-
ciency, high reliability, low output voltage noise and excel-
lent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occuring on the source lines. Input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified ranges. Certain types
include an inrush current limitation preventing circuit break-
ers and fuses from being damaged at switch-on.
All outputs are open- and short-circuit proof and are pro-
tected against overvoltages by means of a built-in suppres-
sor diode. The outputs can be inhibited by a logic signal ap-
plied to the connector pin i. If the inhibit function is not used
pin 18 must be connected with pin 14 to enable the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC 950 and have been approved by the safety agencies
VDE (Germany) and UL (USA). The UL Mark for Canada
has been officially recognized be regulatory authorities in
provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71
°C
but
the case temperature must remain below 95
°C
under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds the
limit. The outputs are automatically re-enabled when the
temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19 inch rack sys-
tems according to DIN 41494, or be chassis mounted.
Case: Aluminium, black finish, self cooling.
8-2
MELCHER
The Power Partners.
Edition 2/96 - © Melcher AG

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号