brick footprint. The output is unregulated and the
5:1 fixed ratio is maintained between the input
and output voltages. It features input voltage
range of 38V to 55V, and provides up to 300W @
48Vin of power. Typical efficiency of 9.6V module
is 96%. It can be parallel for more power.
Output voltage set point
Output load regulation
Output voltage total regulation
Output ripple & noise
2
Output current operating range
Efficiency
Turn-on delay
Output voltage rise time
3
Start-up inhibit time
Transient response
3
Current sharing accuracy
Output turn on overshoot
Output turn off undershoot
Maximum output capacitance
7.0
50
0
96
0.1
10
150
±3
3
0
0
11.0
150
34
10
15
10
3
3
3000
1 V
IN
= 48Vdc, Ta = 25ºC, Airflow = 200 LFM for all data unless otherwise noted.
2 Output Ripple Voltage and noise is specified when measured with a 10uF tantalum and a 1μF ceramic capacitor at the output pins.
3 During output voltage rise time (15 mS Max.), output power shall be limited to 50% constant power.
Transient response is specified with a 960μF capacitor at the output of the converter.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
email: sales@murata-ps.com
25 Jun 2010 MDC_EUS34-96.B02Δ
Page 1 of 3
EUS34-096
Isolated Bus Converter
PROTECTION CHARACTERISTICS
Parameter
Output over-current shutdown
2
Over temperature shutdown
3
Over temperature restart hysteresis
Conditions
1
Auto-restart
Re-start rate
Auto-restart
Min.
38
Typ.
40
TBD
135
10
Max.
42
140
Units
A
ms
ºC
ºC
GENERAL CHARACTERISTICS
Parameter
Isolation voltage
Isolation resistance
Storage temperature range
Operating temperature range
Operating humidity
Thermal measurement location temperature
3
Material flammability
MTBF
Conditions
Input to output
Input to output
Non-condensing
Non-condensing
See mechanical drawing for location
UL 94V-0
Calculated per Mil Spec 217 E, or Bellcore at Ta=30ºC
Demonstrated
Min.
2250
10
-40
-40
10
Typ.
Max.
Units
V
DC
MΩ
ºC
ºC
%
ºC
x10
6
Hrs
x10
6
Hrs
125
85
90
130
2
1.3
STANDARDS COMPLIANCE
Standards
UL/CSA 60950
Conditions
4
Basic insulation
MANUFACTURING TESTING
Burn-in test
Parametric test
SAFETY CONSIDERATIONS
This series of converters are certified to the standards and extent listed in the ‘Standards Compliance’ section in the table above. If this product is built into
information technology equipment, the installation must comply with the above standard. Even though the product is safety certified to operate without an input
fuse, it is recommended that an input fuse of 12A (max.) is used.
The output of the converter (Vo+/Vo-) is considered to remain within SELV limits when the input to the converter meets SELV or TNV-2 requirements. The
converters and materials meet UL 94V-0 flammability ratings.
RoHS COMPLIANCE
The EUS34-096 converter is in compliance with the European Union Directive 2002/95/EC (RoHS) with respect to the
following substances: lead (Pb), cadmium (Cd), mercury (Hg), hexavalent chromium, polybrominated biphenyls (PBB) and
polybrominated diphenyl ethers (PBDE).
For further information, please visit www.cd4power.com/rohs
1
2
3
4
V
IN
= 48Vdc, Ta = 25ºC, Airflow = 200 LFM for all data unless otherwise noted.
Input transient: if input voltage increases by 5V in 1μs, output over-current shut-down shall not be triggered (tested with Max. load and Max. output capacitance).
Thermal shutdown is monitored at the Thermal Measurement Location (TML). See ‘Mechanical Information’ on page 3 for TML location.
See ‘Safety Considerations’ shown on page 4.
Derating curves are conducted in a controlled environment. End application testing is required to ensure the Thermal Measurement Location temperature is below the maximum specified.
Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transversal to the unit).
www.murata-ps.com
email: sales@murata-ps.com
25 Jun 2010 MDC_EUS34-96.B02Δ
Page 2 of 3
EUS34-096
Isolated Bus Converter
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
0.480
(12.19)
Max.
Ø0.040 ± 0.002 (1.02 ± 0.06)
(3X)
Ø0.062 ± 0.002 (1.57 ± 0.06)
(2X)
2.28 (57.9)
y
TML
0.300 (7.62)
PIN #4
0.90
(22.9)
PIN #5
Recommended
Footprint
Ø0.060 (1.52)
Ø0.105 (2.67)
Ø0.093 (2.36)
Ø0.137 (3.48)
0.300
(7.62)
PIN #3
0.45
(11.4)
PIN #2
0.14 (3.6)
PIN #1
0.300 (7.62)
2.000 (50.80)
Bottom view
0.300 (7.62)
Dimensions: 2.3 (58.4) L x 1.45 (36.83) W x 0.48 (12.19) H
This small board was just released in June and July 2019. It has 128 NVIDIA CUDA and quad-core CortexA57. It can run a large number of CUDA (or CPU)-based artificial intelligence and image processing ...
Since RAM data will be lost when power is lost, if the RAM+FLASH+power-off detection circuit solution is adopted, how much data can be transferred to the flash when power is detected? The processor ca...
[align=left][font=微软雅黑, "][size=14px][size=3][color=#000000]Implementation of the Second Kalman Filter[/color][/size][/size][/font][/align][align=left][font=微软雅黑, "][size=14px][size=3][color=#000000]T...
The MSP430 product line introduced the first microcontroller with an integrated LCD. Since then, TI has launched a strong product line that now supports more than 100 products with LCDs and up to 512K...
[align=center][/align] [align=left][size=4]Excellent resources on power supply, no points required for downloading this week. [/size][/align] [align=left][i][size=4][color=#ff0000]You can also downloa...